These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
117 related articles for article (PubMed ID: 2432579)
21. Dual chamber pacing: how many patients remain in DDD mode over the long term? Ibrahim B; Sanderson JE; Wright B; Palmer R Br Heart J; 1995 Jul; 74(1):76-9. PubMed ID: 7662461 [TBL] [Abstract][Full Text] [Related]
22. Deleterious effects of long-term single-chamber ventricular pacing in patients with sick sinus syndrome: the hidden benefits of dual-chamber pacing. Hesselson AB; Parsonnet V; Bernstein AD; Bonavita GJ J Am Coll Cardiol; 1992 Jun; 19(7):1542-9. PubMed ID: 1593051 [TBL] [Abstract][Full Text] [Related]
23. Paroxysmal atrial fibrillation and high degree AV block: use of single-lead VDDR pacing with mode switching. Nowak B; Voigtländer T; Rosocha S; Liebrich A; Zellerhoff C; Przibille O; Geil S; Himmrich E; Meyer J Pacing Clin Electrophysiol; 1998 Oct; 21(10):1927-33. PubMed ID: 9793089 [TBL] [Abstract][Full Text] [Related]
24. The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial: rationale, design, results, clinical implications and lessons for future trials. Wilkoff BL; Card Electrophysiol Rev; 2003 Dec; 7(4):468-72. PubMed ID: 15071277 [TBL] [Abstract][Full Text] [Related]
25. Atrial arrhythmia management with sensor controlled atrial refractory period and automatic mode switching in patients with minute ventilation sensing dual chamber rate adaptive pacemakers. Lau CP; Tai YT; Fong PC; Li JP; Chung FL Pacing Clin Electrophysiol; 1992 Oct; 15(10 Pt 1):1504-14. PubMed ID: 1383962 [TBL] [Abstract][Full Text] [Related]
26. Minimizing ventricular pacing to reduce atrial fibrillation in sinus-node disease. Sweeney MO; Bank AJ; Nsah E; Koullick M; Zeng QC; Hettrick D; Sheldon T; Lamas GA; N Engl J Med; 2007 Sep; 357(10):1000-8. PubMed ID: 17804844 [TBL] [Abstract][Full Text] [Related]
27. DDD pacing mode survival in patients with a dual-chamber pacemaker. Gross JN; Moser S; Benedek ZM; Andrews C; Furman S J Am Coll Cardiol; 1992 Jun; 19(7):1536-41. PubMed ID: 1593050 [TBL] [Abstract][Full Text] [Related]
28. Higher sympathetic nerve activity during ventricular (VVI) than during dual-chamber (DDD) pacing. Taylor JA; Morillo CA; Eckberg DL; Ellenbogen KA J Am Coll Cardiol; 1996 Dec; 28(7):1753-8. PubMed ID: 8962562 [TBL] [Abstract][Full Text] [Related]
29. Increased base rate of atrial pacing for prevention of atrial fibrillation after implantation of a dual-chamber pacemaker: insights from the Atrial Overdrive Pacing Study. Kantharia BK; Freedman RA; Hoekenga D; Tomassoni G; Worley S; Sorrentino R; Steinhaus D; Wolkowicz JM; Syed ZA; Europace; 2007 Nov; 9(11):1024-30. PubMed ID: 17913697 [TBL] [Abstract][Full Text] [Related]
30. Rate-responsive pacing: clinical experience. Goicolea de Oro A; Ayza MW; de la Llana R; Alvarez Morales J; Gutiérrez Díez JR; González Alvarez J Pacing Clin Electrophysiol; 1985 May; 8(3 Pt 1):322-8. PubMed ID: 2582377 [TBL] [Abstract][Full Text] [Related]
31. The use of implantable sensors for the control of pacemaker mediated tachycardias: a comparative evaluation between minute ventilation sensing and acceleration sensing dual chamber rate adaptive pacemakers. Lau CP; Tai YT; Fong PC; Li JP; Chung FL; Song S Pacing Clin Electrophysiol; 1992 Jan; 15(1):34-44. PubMed ID: 1370998 [TBL] [Abstract][Full Text] [Related]
32. A comparative study on the behavior of three different automatic mode switching dual chamber pacemakers to intracardiac recordings of clinical atrial fibrillation. Leung SK; Lau CP; Lam CT; Tse HF; Tang MO; Chung F; Ayers G Pacing Clin Electrophysiol; 2000 Dec; 23(12):2086-96. PubMed ID: 11202252 [TBL] [Abstract][Full Text] [Related]
33. [Benefits and limits of single chamber atrial pacing with adaptive rate]. Pouillot C; Mabo P; Lelong B; Cazeau S; Paillard F; de Place C; Daubert JC Arch Mal Coeur Vaiss; 1990 Nov; 83(12):1833-42. PubMed ID: 2125194 [TBL] [Abstract][Full Text] [Related]