These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 24326314)

  • 1. Digital pulse processing and optimization of the front-end electronics for nuclear instrumentation.
    Bobin C; Bouchard J; Thiam C; Ménesguen Y
    Appl Radiat Isot; 2014 May; 87():195-9. PubMed ID: 24326314
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Overview of a FPGA-based nuclear instrumentation dedicated to primary activity measurements.
    Bobin C; Bouchard J; Pierre S; Thiam C
    Appl Radiat Isot; 2012 Sep; 70(9):2012-7. PubMed ID: 22405958
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Extending the dynamic range of nuclear pulse spectrometers.
    Pullia A; Zocca F; Pascovici G; Bazzacco D
    Rev Sci Instrum; 2008 Mar; 79(3):036105. PubMed ID: 18377050
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Digital pulse processing: new possibilities in nuclear spectroscopy.
    Warburton WK; Momayezi M; Hubbard-Nelson B; Skulski W
    Appl Radiat Isot; 2000 Oct; 53(4-5):913-20. PubMed ID: 11003541
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A front-end readout Detector Board for the OpenPET electronics system.
    Choong WS; Abu-Nimeh F; Moses WW; Peng Q; Vu CQ; Wu JY
    J Instrum; 2015 Aug; 10():. PubMed ID: 27134641
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A digitizer based compact digital spectrometer for ion beam analysis using Field Programmable Gate Arrays and various energy algorithms.
    Jäger M; Reinert T
    Rev Sci Instrum; 2013 Aug; 84(8):085105. PubMed ID: 24007105
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development of new CdZnTe detectors for room-temperature high-flux radiation measurements.
    Abbene L; Gerardi G; Raso G; Principato F; Zambelli N; Benassi G; Bettelli M; Zappettini A
    J Synchrotron Radiat; 2017 Mar; 24(Pt 2):429-438. PubMed ID: 28244436
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sparsity-based pulse-processor for digital α-particle spectroscopy with Si-PIN-Diode detector.
    Ashrafi S; Kasani H; Ghal-Eh N; Vega-Carrillo HR
    Appl Radiat Isot; 2020 Sep; 163():109245. PubMed ID: 32561035
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characterization of a 2D soft x-ray tomography camera with discrimination in energy bands.
    Romano A; Pacella D; Mazon D; Murtas F; Malard P; Gabellieri L; Tilia B; Piergotti V; Corradi G
    Rev Sci Instrum; 2010 Oct; 81(10):10E523. PubMed ID: 21034051
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of digital pulse processing techniques for a β-γ coincidence counting system.
    Durán MT; Nedjadi Y; Juget F; Bochud F; Bailat C
    Appl Radiat Isot; 2020 May; 159():109100. PubMed ID: 32250773
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reset charge sensitive amplifier for NaI(Tl) gamma-ray spectrometer.
    Zeng G; Tan C; Li Q; Ge L; Liu X; Luo Q
    Appl Radiat Isot; 2015 Mar; 97():63-69. PubMed ID: 25544664
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A pixel detector-based single photon-counting system as fast spectrometer for diagnostic X-ray beams.
    Carpentieri C; Bisogni MG; Del Guerra A; Delogu P; Fantacci ME; Fogli J; Marchi A; Marzulli V; Rosso V; Stefanini A; Tofani A
    Radiat Prot Dosimetry; 2008; 129(1-3):119-22. PubMed ID: 18487616
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Peak tailing cancellation techniques for digital CR-(RC)
    Hong X; Wang H; Zhou J; Yang X; Wang M; Ma Y; Zhou W; Liu Y; Zhu X
    Appl Radiat Isot; 2021 Jan; 167():109471. PubMed ID: 33068986
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Gamma-ray spectroscopy with anode pulses of NaI(Tl) detector using a low-cost digitizer system.
    Kasani H; Ashrafi S; Ghal-Eh N; Vega-Carrillo HR
    Appl Radiat Isot; 2021 Oct; 176():109854. PubMed ID: 34252749
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A New Statistics-Based Online Baseline Restorer for a High Count-Rate Fully Digital System.
    Li H; Wang C; Baghaei H; Zhang Y; Ramirez R; Liu S; An S; Wong WH
    IEEE Trans Nucl Sci; 2010 Apr; 57(2):550-555. PubMed ID: 20485535
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A new digital 4πγ system with a NaI well-type detector at LMR-CNEA.
    Rossi M; Balpardo C; Arenillas P; Cerutti G; Ferrari MC
    Appl Radiat Isot; 2018 Apr; 134():337-339. PubMed ID: 29126695
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Digital discrimination of neutrons and gamma-rays in organic scintillation detectors using moment analysis.
    Xie X; Zhang X; Yuan X; Chen J; Li X; Zhang G; Fan T; Yuan G; Yang J; Yang Q
    Rev Sci Instrum; 2012 Sep; 83(9):093507. PubMed ID: 23020376
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Data Analysis and Filter Optimization for Pulse-Amplitude Measurement: A Case Study on High-Resolution X-ray Spectroscopy.
    Mannatunga KS; Valinoti B; Florian Samayoa W; Crespo ML; Cicuttin A; Folla Kamdem J; Garcia LG; Carrato S
    Sensors (Basel); 2022 Jun; 22(13):. PubMed ID: 35808271
    [TBL] [Abstract][Full Text] [Related]  

  • 19. First performance tests of a digital photon counter (DPC) array coupled to a CsI(Tl) crystal matrix for potential use in SPECT.
    Georgiou M; Borghi G; Spirou SV; Loudos G; Schaart DR
    Phys Med Biol; 2014 May; 59(10):2415-30. PubMed ID: 24743522
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel low-power-implantable epileptic seizure-onset detector.
    Salam MT; Sawan M; Dang Khoa Nguyen
    IEEE Trans Biomed Circuits Syst; 2011 Dec; 5(6):568-78. PubMed ID: 23852554
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.