53 related articles for article (PubMed ID: 24338968)
1. Large-volume injection combined with gas chromatography/isotope ratio mass spectrometry for the analysis of polycyclic aromatic hydrocarbons.
Buczyńska AJ; Geypens B; Van Grieken R; De Wael K
Rapid Commun Mass Spectrom; 2014 Jan; 28(2):200-8. PubMed ID: 24338968
[TBL] [Abstract][Full Text] [Related]
2. Optimization of a large-volume injection method for compound-specific isotope analysis of polycyclic aromatic compounds at trace concentrations.
Blessing M; Jochmann MA; Haderlein SB; Schmidt TC
Rapid Commun Mass Spectrom; 2015 Dec; 29(24):2349-60. PubMed ID: 26563706
[TBL] [Abstract][Full Text] [Related]
3. Use of a temperature-programmable injector coupled to gas chromatography-combustion-isotope ratio mass spectrometry for compound-specific carbon isotopic analysis of polycyclic aromatic hydrocarbons.
Mikolajczuk A; Geypens B; Berglund M; Taylor P
Rapid Commun Mass Spectrom; 2009 Aug; 23(16):2421-7. PubMed ID: 19603473
[TBL] [Abstract][Full Text] [Related]
4. Solid-phase extraction combined with large volume injection-programmable temperature vaporization-gas chromatography-mass spectrometry for the multiresidue determination of priority and emerging organic pollutants in wastewater.
Bizkarguenaga E; Ros O; Iparraguirre A; Navarro P; Vallejo A; Usobiaga A; Zuloaga O
J Chromatogr A; 2012 Jul; 1247():104-17. PubMed ID: 22673809
[TBL] [Abstract][Full Text] [Related]
5. Microwave-assisted extraction and dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry for isolation and determination of polycyclic aromatic hydrocarbons in smoked fish.
Ghasemzadeh-Mohammadi V; Mohammadi A; Hashemi M; Khaksar R; Haratian P
J Chromatogr A; 2012 May; 1237():30-6. PubMed ID: 22483095
[TBL] [Abstract][Full Text] [Related]
6. Analysis of polycyclic aromatic hydrocarbons in aqueous samples by large volume injection gas chromatography-mass spectrometry using the through oven transfer adsorption desorption interface.
Aragón Á; Toledano RM; Vázquez A; Villén J; Cortés JM
Talanta; 2015 Jul; 139():1-5. PubMed ID: 25882400
[TBL] [Abstract][Full Text] [Related]
7. Analysis of alkyl and 2-6-ringed polycyclic aromatic hydrocarbons by isotope dilution gas chromatography/mass spectrometry. Quality assurance and determination in Spanish river sediments.
Planas C; Puig A; Rivera J; Caixach J
J Chromatogr A; 2006 Apr; 1113(1-2):220-30. PubMed ID: 16513126
[TBL] [Abstract][Full Text] [Related]
8. Determination of PAHs in airborne particles by accelerated solvent extraction and large-volume injection-gas chromatography-mass spectrometry.
Yusà V; Quintas G; Pardo O; Pastor A; Guardia Mde L
Talanta; 2006 Jun; 69(4):807-15. PubMed ID: 18970641
[TBL] [Abstract][Full Text] [Related]
9. Gas chromatography/isotope ratio mass spectrometry of recalcitrant target compounds: performance of different combustion reactors and strategies for standardization.
Reinnicke S; Juchelka D; Steinbeiss S; Meyer A; Hilkert A; Elsner M
Rapid Commun Mass Spectrom; 2012 May; 26(9):1053-60. PubMed ID: 22467455
[TBL] [Abstract][Full Text] [Related]
10. Isolation of neutral and acidic lipid biomarker classes for compound-specific-carbon isotope analysis by means of solvent extraction and normal-phase high-performance liquid chromatography.
Tolosa I; de Mora S
J Chromatogr A; 2004 Aug; 1045(1-2):71-84. PubMed ID: 15378881
[TBL] [Abstract][Full Text] [Related]
11. Accurate quantification of polycyclic aromatic hydrocarbons in dust samples using microwave-assisted solvent extraction combined with isotope-dilution mass spectrometry.
Itoh N; Fushimi A; Yarita T; Aoyagi Y; Numata M
Anal Chim Acta; 2011 Aug; 699(1):49-56. PubMed ID: 21704757
[TBL] [Abstract][Full Text] [Related]
12. Modified sampling and analysis method for large volatility range airborne polycyclic aromatic hydrocarbons (PAH) using gas chromatography-mass spectrometry.
Wybraniec S; De Jong AP
Anal Bioanal Chem; 1996 Oct; 356(6):396-402. PubMed ID: 15048341
[TBL] [Abstract][Full Text] [Related]
13. Isotope ratio determination in boron analysis.
Sah RN; Brown PH
Biol Trace Elem Res; 1998; 66(1-3):39-53. PubMed ID: 10050906
[TBL] [Abstract][Full Text] [Related]
14. Rapid and sensitive determination of polycyclic aromatic hydrocarbons in atmospheric particulates using fast high-performance liquid chromatography with on-line enrichment system.
Hashi Y; Wang TR; Du W; Lin JM
Talanta; 2008 Jan; 74(4):986-91. PubMed ID: 18371738
[TBL] [Abstract][Full Text] [Related]
15. Innovative method for determination of 19 polycyclic aromatic hydrocarbons in food and oil samples using gas chromatography coupled to tandem mass spectrometry based on an isotope dilution approach.
Veyrand B; Brosseaud A; Sarcher L; Varlet V; Monteau F; Marchand P; Andre F; Le Bizec B
J Chromatogr A; 2007 May; 1149(2):333-44. PubMed ID: 17395191
[TBL] [Abstract][Full Text] [Related]
16. Direct gas injection method: a simple modification to an elemental analyzer/isotope ratio mass spectrometer for stable isotope analysis of N and C from N2O and CO2 gases in nanomolar concentrations.
Machavaram MV; Beaulieu JJ; Mills MA
Rapid Commun Mass Spectrom; 2013 Jan; 27(1):97-102. PubMed ID: 23239321
[TBL] [Abstract][Full Text] [Related]
17. Analysis of semi-volatile organic compounds in indoor suspended particulate matter by thermal desorption coupled with gas chromatography/mass spectrometry.
Mercier F; Glorennec P; Blanchard O; Le Bot B
J Chromatogr A; 2012 Sep; 1254():107-14. PubMed ID: 22840824
[TBL] [Abstract][Full Text] [Related]
18. Determination of particulate and gaseous phthalic acid esters in ambient air by large-volume injection-gas chromatography-mass spectrometry.
Wang SL; Wang P; Fan CQ
J Environ Monit; 2009 Apr; 11(4):882-6. PubMed ID: 19557244
[TBL] [Abstract][Full Text] [Related]
19. Comprehensive analysis of polycyclic aromatic hydrocarbons in wastewater using stir bar sorptive extraction and gas chromatography coupled to tandem mass spectrometry.
Barco-Bonilla N; Romero-González R; Plaza-Bolaños P; Fernández-Moreno JL; Frenich AG; Vidal JL
Anal Chim Acta; 2011 May; 693(1-2):62-71. PubMed ID: 21504812
[TBL] [Abstract][Full Text] [Related]
20. Compound-specific carbon isotope analysis of volatile organic compounds in the low-microgram per liter range.
Zwank L; Berg M; Schmidt TC; Haderlein SB
Anal Chem; 2003 Oct; 75(20):5575-83. PubMed ID: 14710841
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]