146 related articles for article (PubMed ID: 24339236)
1. Epicocconone staining: a powerful loading control for Western blots.
Moritz CP; Marz SX; Reiss R; Schulenborg T; Friauf E
Proteomics; 2014 Feb; 14(2-3):162-8. PubMed ID: 24339236
[TBL] [Abstract][Full Text] [Related]
2. Stain-free detection as loading control alternative to Ponceau and housekeeping protein immunodetection in Western blotting.
Rivero-Gutiérrez B; Anzola A; Martínez-Augustin O; de Medina FS
Anal Biochem; 2014 Dec; 467():1-3. PubMed ID: 25193447
[TBL] [Abstract][Full Text] [Related]
3. Tubulin or Not Tubulin: Heading Toward Total Protein Staining as Loading Control in Western Blots.
Moritz CP
Proteomics; 2017 Oct; 17(20):. PubMed ID: 28941183
[TBL] [Abstract][Full Text] [Related]
4. Direct Blue 71 staining as a destaining-free alternative loading control method for Western blotting.
Zeng L; Guo J; Xu HB; Huang R; Shao W; Yang L; Wang M; Chen J; Xie P
Electrophoresis; 2013 Aug; 34(15):2234-9. PubMed ID: 23712695
[TBL] [Abstract][Full Text] [Related]
5. Use of the REVERT
Kirshner ZZ; Gibbs RB
Mol Cell Endocrinol; 2018 Sep; 473():156-165. PubMed ID: 29396126
[TBL] [Abstract][Full Text] [Related]
6. Housekeeping proteins: How useful are they in skeletal muscle diabetes studies and muscle hypertrophy models?
Fortes MA; Marzuca-Nassr GN; Vitzel KF; da Justa Pinheiro CH; Newsholme P; Curi R
Anal Biochem; 2016 Jul; 504():38-40. PubMed ID: 27060530
[TBL] [Abstract][Full Text] [Related]
7. Western blot normalization: Time to choose a proper loading control seriously.
Wang Q; Han W; Ma C; Wang T; Zhong J
Electrophoresis; 2023 May; 44(9-10):854-863. PubMed ID: 36645159
[TBL] [Abstract][Full Text] [Related]
8. GAPDH and β-actin protein decreases with aging, making Stain-Free technology a superior loading control in Western blotting of human skeletal muscle.
Vigelsø A; Dybboe R; Hansen CN; Dela F; Helge JW; Guadalupe Grau A
J Appl Physiol (1985); 2015 Feb; 118(3):386-94. PubMed ID: 25429098
[TBL] [Abstract][Full Text] [Related]
9. Coomassie staining as loading control in Western blot analysis.
Welinder C; Ekblad L
J Proteome Res; 2011 Mar; 10(3):1416-9. PubMed ID: 21186791
[TBL] [Abstract][Full Text] [Related]
10. Standard loading controls are not reliable for Western blot quantification across brain development or in pathological conditions.
Goasdoue K; Awabdy D; Bjorkman ST; Miller S
Electrophoresis; 2016 Feb; 37(4):630-4. PubMed ID: 26593451
[TBL] [Abstract][Full Text] [Related]
11. Western blotting using in-gel protein labeling as a normalization control: stain-free technology.
Gilda JE; Gomes AV
Methods Mol Biol; 2015; 1295():381-91. PubMed ID: 25820735
[TBL] [Abstract][Full Text] [Related]
12. Housekeeping genes; expression levels may change with density of cultured cells.
Greer S; Honeywell R; Geletu M; Arulanandam R; Raptis L
J Immunol Methods; 2010 Apr; 355(1-2):76-9. PubMed ID: 20171969
[TBL] [Abstract][Full Text] [Related]
13. Total protein staining with Congo red as an alternative loading control for western blot analysis.
Wang JL; Li MQ; Zhang JJ; Xu CJ
Biotech Histochem; 2022 Aug; 97(6):404-414. PubMed ID: 34903132
[TBL] [Abstract][Full Text] [Related]
14. Stain-Free total protein staining is a superior loading control to β-actin for Western blots.
Gilda JE; Gomes AV
Anal Biochem; 2013 Sep; 440(2):186-8. PubMed ID: 23747530
[TBL] [Abstract][Full Text] [Related]
15. Reversible Ponceau staining as a loading control alternative to actin in Western blots.
Romero-Calvo I; Ocón B; Martínez-Moya P; Suárez MD; Zarzuelo A; Martínez-Augustin O; de Medina FS
Anal Biochem; 2010 Jun; 401(2):318-20. PubMed ID: 20206115
[TBL] [Abstract][Full Text] [Related]
16. Glyceraldehyde-3-phosphate dehydrogenase is a reliable internal control in Western blot analysis of leukocyte subpopulations from children.
Yu HR; Kuo HC; Huang HC; Huang LT; Tain YL; Chen CC; Liang CD; Sheen JM; Lin IC; Wu CC; Ou CY; Yang KD
Anal Biochem; 2011 Jun; 413(1):24-9. PubMed ID: 21284931
[TBL] [Abstract][Full Text] [Related]
17. The use of total protein stains as loading controls: an alternative to high-abundance single-protein controls in semi-quantitative immunoblotting.
Aldridge GM; Podrebarac DM; Greenough WT; Weiler IJ
J Neurosci Methods; 2008 Jul; 172(2):250-4. PubMed ID: 18571732
[TBL] [Abstract][Full Text] [Related]
18. Rapid fluorescent monitoring of total protein patterns on sodium dodecyl sulfate-polyacrylamide gels and western blots before immunodetection and sequencing.
Alba FJ; Daban JR
Electrophoresis; 1998 Oct; 19(14):2407-11. PubMed ID: 9820958
[TBL] [Abstract][Full Text] [Related]
19. Total protein or high-abundance protein: Which offers the best loading control for Western blotting?
Thacker JS; Yeung DH; Staines WR; Mielke JG
Anal Biochem; 2016 Mar; 496():76-8. PubMed ID: 26706797
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of SYPRO Ruby total protein stain for the normalization of two-dimensional Western blots.
Steinberger B; Brem G; Mayrhofer C
Anal Biochem; 2015 May; 476():17-9. PubMed ID: 25640586
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]