186 related articles for article (PubMed ID: 24342544)
1. Unicompartmental knee arthroplasties: robot vs. patient specific instrumentation.
Jaffry Z; Masjedi M; Clarke S; Harris S; Karia M; Andrews B; Cobb J
Knee; 2014 Mar; 21(2):428-34. PubMed ID: 24342544
[TBL] [Abstract][Full Text] [Related]
2. A novel patient-specific instrument design can deliver robotic level accuracy in unicompartmental knee arthroplasty.
Jones GG; Clarke S; Harris S; Jaere M; Aldalmani T; de Klee P; Cobb JP
Knee; 2019 Dec; 26(6):1421-1428. PubMed ID: 31519328
[TBL] [Abstract][Full Text] [Related]
3. [Total and unicompartmental knee replacement. Patient-specific Instrumentation].
Köster G; Biró C
Orthopade; 2016 Apr; 45(4):302-13. PubMed ID: 27025869
[TBL] [Abstract][Full Text] [Related]
4. Clinical Study of 3D Imaging and 3D Printing Technique for Patient-Specific Instrumentation in Total Knee Arthroplasty.
Qiu B; Liu F; Tang B; Deng B; Liu F; Zhu W; Zhen D; Xue M; Zhang M
J Knee Surg; 2017 Oct; 30(8):822-828. PubMed ID: 28122388
[TBL] [Abstract][Full Text] [Related]
5. [The MyKnee® patient-specific system. Rationale, Technique and Results].
Anderl W; Pauzenberger L; Schwameis E
Orthopade; 2016 Apr; 45(4):294-301. PubMed ID: 27025868
[TBL] [Abstract][Full Text] [Related]
6. Unicompartmental knee arthroplasty: is robotic technology more accurate than conventional technique?
Citak M; Suero EM; Citak M; Dunbar NJ; Branch SH; Conditt MA; Banks SA; Pearle AD
Knee; 2013 Aug; 20(4):268-71. PubMed ID: 23201147
[TBL] [Abstract][Full Text] [Related]
7. Design improvement in patient-specific instrumentation for total knee arthroplasty improved the accuracy of the tibial prosthetic alignment in the coronal and axial planes.
Yamamura K; Minoda Y; Sugama R; Ohta Y; Nakamura S; Ueyama H; Nakamura H
Knee Surg Sports Traumatol Arthrosc; 2020 May; 28(5):1560-1567. PubMed ID: 31240377
[TBL] [Abstract][Full Text] [Related]
8. Implant orientation accuracy of a hand-held robotic partial knee replacement system over conventional technique in a cadaveric test.
Khare R; Jaramaz B; Hamlin B; Urish KL
Comput Assist Surg (Abingdon); 2018 Dec; 23(1):8-13. PubMed ID: 29932791
[TBL] [Abstract][Full Text] [Related]
9. An Experienced Surgeon Can Meet or Exceed Robotic Accuracy in Manual Unicompartmental Knee Arthroplasty.
Bush AN; Ziemba-Davis M; Deckard ER; Meneghini RM
J Bone Joint Surg Am; 2019 Aug; 101(16):1479-1484. PubMed ID: 31436656
[TBL] [Abstract][Full Text] [Related]
10. Postoperative mechanical alignment analysis of total knee replacement patients operated with 3D printed patient specific instruments: A Prospective Cohort Study.
Gemalmaz HC; Sarıyılmaz K; Ozkunt O; Sungur M; Kaya I; Dikici F
Acta Orthop Traumatol Turc; 2019 Sep; 53(5):323-328. PubMed ID: 30853398
[TBL] [Abstract][Full Text] [Related]
11. Do patient-specific instruments (PSI) for UKA allow non-expert surgeons to achieve the same saw cut accuracy as expert surgeons?
Jones GG; Logishetty K; Clarke S; Collins R; Jaere M; Harris S; Cobb JP
Arch Orthop Trauma Surg; 2018 Nov; 138(11):1601-1608. PubMed ID: 30178169
[TBL] [Abstract][Full Text] [Related]
12. The John Insall Award: No Functional Benefit After Unicompartmental Knee Arthroplasty Performed With Patient-specific Instrumentation: A Randomized Trial.
Ollivier M; Parratte S; Lunebourg A; Viehweger E; Argenson JN
Clin Orthop Relat Res; 2016 Jan; 474(1):60-8. PubMed ID: 25791446
[TBL] [Abstract][Full Text] [Related]
13. [Total knee arthroplasty with the use of patient specific instruments. The VISIONAIRE system].
Tibesku CO
Orthopade; 2016 Apr; 45(4):286-93. PubMed ID: 26952362
[TBL] [Abstract][Full Text] [Related]
14. Accuracy of a freehand sculpting tool for unicondylar knee replacement.
Smith JR; Riches PE; Rowe PJ
Int J Med Robot; 2014 Jun; 10(2):162-9. PubMed ID: 23934937
[TBL] [Abstract][Full Text] [Related]
15. Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment.
Moon YW; Ha CW; Do KH; Kim CY; Han JH; Na SE; Lee CH; Kim JG; Park YS
Comput Aided Surg; 2012; 17(2):86-95. PubMed ID: 22348661
[TBL] [Abstract][Full Text] [Related]
16. Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty.
Huijbregts HJ; Khan RJ; Sorensen E; Fick DP; Haebich S
Acta Orthop; 2016 Aug; 87(4):386-94. PubMed ID: 27249110
[TBL] [Abstract][Full Text] [Related]
17. Tibial baseplate positioning in robotic-assisted and conventional unicompartmental knee arthroplasty.
MacCallum KP; Danoff JR; Geller JA
Eur J Orthop Surg Traumatol; 2016 Jan; 26(1):93-8. PubMed ID: 26441329
[TBL] [Abstract][Full Text] [Related]
18. Significant differences between manufacturer and surgeon in the accuracy of final component size prediction with CT-based patient-specific instrumentation for total knee arthroplasty.
Cucchi D; Menon A; Compagnoni R; Ferrua P; Fossati C; Randelli P
Knee Surg Sports Traumatol Arthrosc; 2018 Nov; 26(11):3317-3324. PubMed ID: 29453487
[TBL] [Abstract][Full Text] [Related]
19. Improved femoral component rotation in TKA using patient-specific instrumentation.
Heyse TJ; Tibesku CO
Knee; 2014 Jan; 21(1):268-71. PubMed ID: 23140905
[TBL] [Abstract][Full Text] [Related]
20. A radiological analysis of the difference between MRI- and CT-based patient-specific matched guides for total knee arthroplasty from the same manufacturer: a randomised controlled trial.
Schotanus MG; Sollie R; van Haaren EH; Hendrickx RP; Jansen EJ; Kort NP
Bone Joint J; 2016 Jun; 98-B(6):786-92. PubMed ID: 27235521
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]