212 related articles for article (PubMed ID: 24348742)
1. Low-dose and scatter-free cone-beam CT imaging using a stationary beam blocker in a single scan: phantom studies.
Dong X; Petrongolo M; Niu T; Zhu L
Comput Math Methods Med; 2013; 2013():637614. PubMed ID: 24348742
[TBL] [Abstract][Full Text] [Related]
2. Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan.
Niu T; Zhu L
Med Phys; 2011 Nov; 38(11):6027-38. PubMed ID: 22047367
[TBL] [Abstract][Full Text] [Related]
3. Empirical scatter correction: CBCT scatter artifact reduction without prior information.
Trapp P; Maier J; Susenburger M; Sawall S; Kachelrieß M
Med Phys; 2022 Jul; 49(7):4566-4584. PubMed ID: 35390181
[TBL] [Abstract][Full Text] [Related]
4. Scatter correction for cone-beam computed tomography using moving blocker strips: a preliminary study.
Wang J; Mao W; Solberg T
Med Phys; 2010 Nov; 37(11):5792-800. PubMed ID: 21158291
[TBL] [Abstract][Full Text] [Related]
5. Combining scatter reduction and correction to improve image quality in cone-beam computed tomography (CBCT).
Jin JY; Ren L; Liu Q; Kim J; Wen N; Guan H; Movsas B; Chetty IJ
Med Phys; 2010 Nov; 37(11):5634-44. PubMed ID: 21158275
[TBL] [Abstract][Full Text] [Related]
6. Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images.
Niu T; Sun M; Star-Lack J; Gao H; Fan Q; Zhu L
Med Phys; 2010 Oct; 37(10):5395-406. PubMed ID: 21089775
[TBL] [Abstract][Full Text] [Related]
7. Local filtration based scatter correction for cone-beam CT using primary modulation.
Zhu L
Med Phys; 2016 Nov; 43(11):6199. PubMed ID: 27806607
[TBL] [Abstract][Full Text] [Related]
8. Binary moving-blocker-based scatter correction in cone-beam computed tomography with width-truncated projections: proof of concept.
Lee H; Fahimian BP; Xing L
Phys Med Biol; 2017 Mar; 62(6):2176-2193. PubMed ID: 28079527
[TBL] [Abstract][Full Text] [Related]
9. Analytic image reconstruction from partial data for a single-scan cone-beam CT with scatter correction.
Min J; Pua R; Kim I; Han B; Cho S
Med Phys; 2015 Nov; 42(11):6625-40. PubMed ID: 26520753
[TBL] [Abstract][Full Text] [Related]
10. A weighted rebinned backprojection-filtration algorithm from partially beam-blocked data for a single-scan cone-beam CT with hybrid type scatter correction.
Min J; Pua R; Kim C; Park M; Lee J; Ye SJ; Cho S
Med Phys; 2019 Mar; 46(3):1182-1197. PubMed ID: 30592313
[TBL] [Abstract][Full Text] [Related]
11. Multi-energy blended CBCT spectral imaging and scatter-decoupled material decomposition using a spectral modulator with flying focal spot (SMFFS).
Deng Y; Zhou H; Wang Z; Wang AS; Gao H
Med Phys; 2024 Apr; 51(4):2398-2412. PubMed ID: 38477717
[TBL] [Abstract][Full Text] [Related]
12. Single-scan patient-specific scatter correction in computed tomography using peripheral detection of scatter and compressed sensing scatter retrieval.
Meng B; Lee H; Xing L; Fahimian BP
Med Phys; 2013 Jan; 40(1):011907. PubMed ID: 23298098
[TBL] [Abstract][Full Text] [Related]
13. Evaluation and Clinical Application of a Commercially Available Iterative Reconstruction Algorithm for CBCT-Based IGRT.
Mao W; Liu C; Gardner SJ; Siddiqui F; Snyder KC; Kumarasiri A; Zhao B; Kim J; Wen NW; Movsas B; Chetty IJ
Technol Cancer Res Treat; 2019 Jan; 18():1533033818823054. PubMed ID: 30803367
[TBL] [Abstract][Full Text] [Related]
14. Scatter correction for a clinical cone-beam CT system using an optimized stationary beam blocker in a single scan.
Liang X; Jiang Y; Zhao W; Zhang Z; Luo C; Xiong J; Yu S; Yang X; Sun J; Zhou Q; Niu T; Xie Y
Med Phys; 2019 Jul; 46(7):3165-3179. PubMed ID: 31055835
[TBL] [Abstract][Full Text] [Related]
15. Scatter correction in cone-beam CT via a half beam blocker technique allowing simultaneous acquisition of scatter and image information.
Lee H; Xing L; Lee R; Fahimian BP
Med Phys; 2012 May; 39(5):2386-95. PubMed ID: 22559608
[TBL] [Abstract][Full Text] [Related]
16. An unsupervised dual contrastive learning framework for scatter correction in cone-beam CT image.
Wang T; Liu X; Dai J; Zhang C; He W; Liu L; Chan Y; He Y; Zhao H; Xie Y; Liang X
Comput Biol Med; 2023 Oct; 165():107377. PubMed ID: 37651766
[TBL] [Abstract][Full Text] [Related]
17. A practical and robust method for beam blocker-based cone beam CT scatter correction.
Cui H; Jiang X; Tang W; Lu HM; Yang Y
Phys Med Biol; 2023 Feb; 68(4):. PubMed ID: 36634362
[No Abstract] [Full Text] [Related]
18. Technical note: Characterization of novel iterative reconstructed cone beam CT images for dose tracking and adaptive radiotherapy on L-shape linacs.
Lim R; Penoncello GP; Hobbis D; Harrington DP; Rong Y
Med Phys; 2022 Dec; 49(12):7715-7732. PubMed ID: 36031929
[TBL] [Abstract][Full Text] [Related]
19. Relationship between x-ray illumination field size and flat field intensity and its impacts on x-ray imaging.
Dong X; Niu T; Jia X; Zhu L
Med Phys; 2012 Oct; 39(10):5901-9. PubMed ID: 23039629
[TBL] [Abstract][Full Text] [Related]
20. Dual-energy head cone-beam CT using a dual-layer flat-panel detector: Hybrid material decomposition and a feasibility study.
Wang Z; Zhou H; Gu S; Xia Y; Liao H; Deng Y; Gao H
Med Phys; 2023 Nov; 50(11):6762-6778. PubMed ID: 37675888
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]