These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1092 related articles for article (PubMed ID: 2434913)

  • 1. Pulse oximetry in very low birth weight infants with acute and chronic lung disease.
    Ramanathan R; Durand M; Larrazabal C
    Pediatrics; 1987 Apr; 79(4):612-7. PubMed ID: 2434913
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pulse oximetry: an alternative method for the assessment of oxygenation in newborn infants.
    Jennis MS; Peabody JL
    Pediatrics; 1987 Apr; 79(4):524-8. PubMed ID: 2434911
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pulse oximetry in newborn infants with birth weights of 620 to 4285 grams receiving dopamine and dobutamine.
    Sardesai S; Durand M; McEvoy C; Johnson C; Maarek JM
    J Perinatol; 1996; 16(1):31-4. PubMed ID: 8869537
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pulse oximetry for continuous oxygen monitoring in sick newborn infants.
    Durand M; Ramanathan R
    J Pediatr; 1986 Dec; 109(6):1052-6. PubMed ID: 2431130
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pulse oximetry advantages in infants with bronchopulmonary dysplasia.
    Solimano AJ; Smyth JA; Mann TK; Albersheim SG; Lockitch G
    Pediatrics; 1986 Nov; 78(5):844-9. PubMed ID: 3763297
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Limitations of transcutaneous PO2 and PCO2 monitoring in infants with bronchopulmonary dysplasia.
    Rome ES; Stork EK; Carlo WA; Martin RJ
    Pediatrics; 1984 Aug; 74(2):217-20. PubMed ID: 6431388
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Neonatal pulse oximetry: accuracy and reliability.
    Hay WW; Brockway JM; Eyzaguirre M
    Pediatrics; 1989 May; 83(5):717-22. PubMed ID: 2717288
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simultaneous comparison of three noninvasive oximeters in healthy volunteers.
    Mendelson Y; Kent JC; Shahnarian A; Welch GW; Giasi RM
    Med Instrum; 1987 Jun; 21(3):183-8. PubMed ID: 3614041
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Accuracy of a pulse oximeter during hypoxia].
    Tachibana C; Fukada T; Hasegawa R; Satoh K; Furuya Y; Ohe Y
    Masui; 1996 Apr; 45(4):479-82. PubMed ID: 8725606
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients.
    Bernet-Buettiker V; Ugarte MJ; Frey B; Hug MI; Baenziger O; Weiss M
    Pediatrics; 2005 Jan; 115(1):e64-8. PubMed ID: 15601814
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Fiberoptic measurement of arterial oxygen saturation in premature and term neonates].
    Merz U; Peschgens T; Hörnchen H
    Z Geburtshilfe Neonatol; 1999; 203(2):77-80. PubMed ID: 10420515
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Accuracy of measurements of Kontrol 7840, Nellcor N200 and Radiometer OX13 pulse oximeters in infants and young children].
    Poets CF; Seidenberg J; Wilken M; von der Hardt H
    Klin Padiatr; 1993; 205(2):107-10. PubMed ID: 8487476
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An evaluation of a new combined Spo2/PtcCO2 sensor in very low birth weight infants.
    Lacerenza S; De Carolis MP; Fusco FP; La Torre G; Chiaradia G; Romagnoli C
    Anesth Analg; 2008 Jul; 107(1):125-9. PubMed ID: 18635477
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pulse oximetry--an alternative to transcutaneous PO2 in sick newborns.
    Peabody JL; Jennis MS; Emery JR
    Adv Exp Med Biol; 1987; 220():145-50. PubMed ID: 3673756
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of accuracy of pulse oximetry in dogs.
    Jacobson JD; Miller MW; Matthews NS; Hartsfield SM; Knauer KW
    Am J Vet Res; 1992 Apr; 53(4):537-40. PubMed ID: 1586024
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of two wavelength pulse oximetry in neonates and infants.
    Praud JP; Carofilis A; Bridey F; Lacaille F; Dehan M; Gaultier CL
    Pediatr Pulmonol; 1989; 6(3):180-2. PubMed ID: 2470014
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reflectance pulse oximetry from core body in neonates and infants: comparison to arterial blood oxygen saturation and to transmission pulse oximetry.
    Kugelman A; Wasserman Y; Mor F; Goldinov L; Geller Y; Bader D
    J Perinatol; 2004 Jun; 24(6):366-71. PubMed ID: 15057251
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Development of a method of continuous monitoring of spontaneous respiration in the postoperative phase. 1. Normal values for cutaneous pO2- and pCO2-partial pressure together with pulse oximetry determined oxygen saturation in healthy young volunteers].
    Lehmann KA; Asoklis S; Grond S; Huttarsch H
    Anaesthesist; 1992 Mar; 41(3):121-9. PubMed ID: 1570883
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pulse oximetry and transcutaneous oxygen tension in hypoxemic neonates and infants with bronchopulmonary dysplasia.
    Lafeber HN; Fetter WP; van der Wiel AR; Jansen TC
    Adv Exp Med Biol; 1987; 220():181-6. PubMed ID: 3673762
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Comparison of arterial and transcutaneous oxygen partial pressure in infants with bronchopulmonary dysplasia].
    Praud JP; Dreizzen E; Carofilis A; Magny JF; Saby MA; Dehan M; Gabilan JC; Gaultier C
    Arch Fr Pediatr; 1988 Oct; 45(8):537-40. PubMed ID: 3214246
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 55.