1. Pulse oximetry in very low birth weight infants with acute and chronic lung disease. Ramanathan R; Durand M; Larrazabal C Pediatrics; 1987 Apr; 79(4):612-7. PubMed ID: 2434913 [TBL] [Abstract][Full Text] [Related]
2. Pulse oximetry: an alternative method for the assessment of oxygenation in newborn infants. Jennis MS; Peabody JL Pediatrics; 1987 Apr; 79(4):524-8. PubMed ID: 2434911 [TBL] [Abstract][Full Text] [Related]
3. Pulse oximetry in newborn infants with birth weights of 620 to 4285 grams receiving dopamine and dobutamine. Sardesai S; Durand M; McEvoy C; Johnson C; Maarek JM J Perinatol; 1996; 16(1):31-4. PubMed ID: 8869537 [TBL] [Abstract][Full Text] [Related]
4. Pulse oximetry for continuous oxygen monitoring in sick newborn infants. Durand M; Ramanathan R J Pediatr; 1986 Dec; 109(6):1052-6. PubMed ID: 2431130 [TBL] [Abstract][Full Text] [Related]
5. Pulse oximetry advantages in infants with bronchopulmonary dysplasia. Solimano AJ; Smyth JA; Mann TK; Albersheim SG; Lockitch G Pediatrics; 1986 Nov; 78(5):844-9. PubMed ID: 3763297 [TBL] [Abstract][Full Text] [Related]
6. Limitations of transcutaneous PO2 and PCO2 monitoring in infants with bronchopulmonary dysplasia. Rome ES; Stork EK; Carlo WA; Martin RJ Pediatrics; 1984 Aug; 74(2):217-20. PubMed ID: 6431388 [TBL] [Abstract][Full Text] [Related]
7. Neonatal pulse oximetry: accuracy and reliability. Hay WW; Brockway JM; Eyzaguirre M Pediatrics; 1989 May; 83(5):717-22. PubMed ID: 2717288 [TBL] [Abstract][Full Text] [Related]
8. Simultaneous comparison of three noninvasive oximeters in healthy volunteers. Mendelson Y; Kent JC; Shahnarian A; Welch GW; Giasi RM Med Instrum; 1987 Jun; 21(3):183-8. PubMed ID: 3614041 [TBL] [Abstract][Full Text] [Related]
9. [Accuracy of a pulse oximeter during hypoxia]. Tachibana C; Fukada T; Hasegawa R; Satoh K; Furuya Y; Ohe Y Masui; 1996 Apr; 45(4):479-82. PubMed ID: 8725606 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients. Bernet-Buettiker V; Ugarte MJ; Frey B; Hug MI; Baenziger O; Weiss M Pediatrics; 2005 Jan; 115(1):e64-8. PubMed ID: 15601814 [TBL] [Abstract][Full Text] [Related]
11. [Fiberoptic measurement of arterial oxygen saturation in premature and term neonates]. Merz U; Peschgens T; Hörnchen H Z Geburtshilfe Neonatol; 1999; 203(2):77-80. PubMed ID: 10420515 [TBL] [Abstract][Full Text] [Related]
12. [Accuracy of measurements of Kontrol 7840, Nellcor N200 and Radiometer OX13 pulse oximeters in infants and young children]. Poets CF; Seidenberg J; Wilken M; von der Hardt H Klin Padiatr; 1993; 205(2):107-10. PubMed ID: 8487476 [TBL] [Abstract][Full Text] [Related]
13. An evaluation of a new combined Spo2/PtcCO2 sensor in very low birth weight infants. Lacerenza S; De Carolis MP; Fusco FP; La Torre G; Chiaradia G; Romagnoli C Anesth Analg; 2008 Jul; 107(1):125-9. PubMed ID: 18635477 [TBL] [Abstract][Full Text] [Related]
14. Pulse oximetry--an alternative to transcutaneous PO2 in sick newborns. Peabody JL; Jennis MS; Emery JR Adv Exp Med Biol; 1987; 220():145-50. PubMed ID: 3673756 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of accuracy of pulse oximetry in dogs. Jacobson JD; Miller MW; Matthews NS; Hartsfield SM; Knauer KW Am J Vet Res; 1992 Apr; 53(4):537-40. PubMed ID: 1586024 [TBL] [Abstract][Full Text] [Related]
16. Accuracy of two wavelength pulse oximetry in neonates and infants. Praud JP; Carofilis A; Bridey F; Lacaille F; Dehan M; Gaultier CL Pediatr Pulmonol; 1989; 6(3):180-2. PubMed ID: 2470014 [TBL] [Abstract][Full Text] [Related]
17. Reflectance pulse oximetry from core body in neonates and infants: comparison to arterial blood oxygen saturation and to transmission pulse oximetry. Kugelman A; Wasserman Y; Mor F; Goldinov L; Geller Y; Bader D J Perinatol; 2004 Jun; 24(6):366-71. PubMed ID: 15057251 [TBL] [Abstract][Full Text] [Related]
18. [Development of a method of continuous monitoring of spontaneous respiration in the postoperative phase. 1. Normal values for cutaneous pO2- and pCO2-partial pressure together with pulse oximetry determined oxygen saturation in healthy young volunteers]. Lehmann KA; Asoklis S; Grond S; Huttarsch H Anaesthesist; 1992 Mar; 41(3):121-9. PubMed ID: 1570883 [TBL] [Abstract][Full Text] [Related]
19. Pulse oximetry and transcutaneous oxygen tension in hypoxemic neonates and infants with bronchopulmonary dysplasia. Lafeber HN; Fetter WP; van der Wiel AR; Jansen TC Adv Exp Med Biol; 1987; 220():181-6. PubMed ID: 3673762 [TBL] [Abstract][Full Text] [Related]
20. [Comparison of arterial and transcutaneous oxygen partial pressure in infants with bronchopulmonary dysplasia]. Praud JP; Dreizzen E; Carofilis A; Magny JF; Saby MA; Dehan M; Gabilan JC; Gaultier C Arch Fr Pediatr; 1988 Oct; 45(8):537-40. PubMed ID: 3214246 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]