198 related articles for article (PubMed ID: 24351178)

  • 21. Evaluation of Accuracy of Six Blood Glucose Monitoring Systems and Modeling of Possibly Related Insulin Dosing Errors.
    Baumstark A; Jendrike N; Pleus S; Haug C; Freckmann G
    Diabetes Technol Ther; 2017 Oct; 19(10):580-588. PubMed ID: 28704063
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Lot-to-lot variability of test strips and accuracy assessment of systems for self-monitoring of blood glucose according to ISO 15197.
    Baumstark A; Pleus S; Schmid C; Link M; Haug C; Freckmann G
    J Diabetes Sci Technol; 2012 Sep; 6(5):1076-86. PubMed ID: 23063033
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Accuracy Evaluation of Four Blood Glucose Monitoring Systems in Unaltered Blood Samples in the Low Glycemic Range and Blood Samples in the Concentration Range Defined by ISO 15197.
    Freckmann G; Pleus S; Link M; Baumstark A; Schmid C; Högel J; Haug C
    Diabetes Technol Ther; 2015 Sep; 17(9):625-34. PubMed ID: 26062008
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Cook and Chill: Effect of Temperature on the Performance of Nonequilibrated Blood Glucose Meters.
    Deakin S; Steele D; Clarke S; Gribben C; Bexley AM; Laan R; Kerr D
    J Diabetes Sci Technol; 2015 Aug; 9(6):1260-9. PubMed ID: 26292960
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A comprehensive evaluation of the performance of the test strip technology for OneTouch Verio glucose meter systems.
    Bailey T; Chang A; Rosenblit PD; Jones L; Teft G; Setford S; Mahoney J
    Diabetes Technol Ther; 2012 Aug; 14(8):701-9. PubMed ID: 22853721
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Self-monitoring of blood glucose levels requires intensive training for use of meters to obtain reliable and clinically relevant measurements.
    Mohr TA; Pfützner A; Forst S; Forst T; Schöndorf T
    J Diabetes Sci Technol; 2007 Jan; 1(1):56-61. PubMed ID: 19888381
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Performance of blood glucose meters in compliance with current and future clinical ISO15197 accuracy criteria.
    Pfützner A; Hengesbach C; Demircik F; Schipper C; Forst T; Musholt PB
    Curr Med Res Opin; 2014 Feb; 30(2):185-90. PubMed ID: 24156775
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Impact of Xylose on Glucose-Dehydrogenase-Based Blood Glucose Meters for Patient Self-Testing.
    Pfützner A; Demircik F; Sachsenheimer D; Spatz J; Pfützner AH; Ramljak S
    J Diabetes Sci Technol; 2017 May; 11(3):577-583. PubMed ID: 28745092
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Performance of three blood glucose meters.
    Rheney CC; Kirk JK
    Ann Pharmacother; 2000 Mar; 34(3):317-21. PubMed ID: 10917376
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Accuracy of five systems for self-monitoring of blood glucose in the hands of adult lay-users and professionals applying ISO 15197:2013 accuracy criteria and potential insulin dosing errors.
    Jendrike N; Baumstark A; Pleus S; Liebing C; Kamecke U; Haug C; Freckmann G
    Curr Med Res Opin; 2019 Feb; 35(2):301-311. PubMed ID: 29927663
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Factors interfering with the accuracy of five blood glucose meters used in Chinese hospitals.
    Lv H; Zhang GJ; Kang XX; Yuan H; Lv YW; Wang WW; Randall R
    J Clin Lab Anal; 2013 Sep; 27(5):354-66. PubMed ID: 24038220
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of Blood Glucose Meter Efficacy in an Antenatal Diabetes Clinic.
    McGrath RT; Donnelly VC; Glastras SJ; Preda VA; Sheriff N; Ward P; Hocking SL; Fulcher GR
    Diabetes Technol Ther; 2016 Feb; 18(2):68-74. PubMed ID: 26440810
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Evaluation of Roche Accu-Chek Go and Medisense Optium blood glucose meters.
    Hawkins RC
    Clin Chim Acta; 2005 Mar; 353(1-2):127-31. PubMed ID: 15698599
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effect of adverse storage conditions on performance of glucometer test strips.
    Bamberg R; Schulman K; MacKenzie M; Moore J; Olchesky S
    Clin Lab Sci; 2005; 18(4):203-9. PubMed ID: 16315736
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Assessing the Accuracy of Different Glucometers Based on the Laboratory Reference Method.
    Al-Zahrani A; Alshareef R; Farahat F; Borai A
    Clin Lab; 2020 Oct; 66(10):. PubMed ID: 33073954
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Performance of the Roche Accu-Chek active glucose meter to screen for gestational diabetes mellitus using fasting capillary blood.
    Dhatt GS; Agarwal MM; Othman Y; Nair SC
    Diabetes Technol Ther; 2011 Dec; 13(12):1229-33. PubMed ID: 21864017
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Can one point-of-care glucose meter be used for all pediatric and adult hospital patients? Evaluation of three meters, including recently modified test strips.
    Warner JV; Wu JY; Buckingham N; McLeod DS; Mottram B; Carter AC
    Diabetes Technol Ther; 2011 Jan; 13(1):55-62. PubMed ID: 21175272
    [TBL] [Abstract][Full Text] [Related]  

  • 38. System Accuracy Evaluation of Four Systems for Self-Monitoring of Blood Glucose Following ISO 15197 Using a Glucose Oxidase and a Hexokinase-Based Comparison Method.
    Link M; Schmid C; Pleus S; Baumstark A; Rittmeyer D; Haug C; Freckmann G
    J Diabetes Sci Technol; 2015 Apr; 9(5):1041-50. PubMed ID: 25872967
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Accuracy and reliability between glucose meters: A study under normal clinical practice conditions].
    Pariente Rodrigo E; Deib-Morgan K; García de Diego O; García-Velasco P; Sgaramella GA; García González I
    Semergen; 2017; 43(1):20-27. PubMed ID: 26968861
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Is there a suitable point-of-care glucose meter for tight glycemic control? Evaluation of one home-use and four hospital-use meters in an intensive care unit.
    Gijzen K; Moolenaar DL; Weusten JJ; Pluim HJ; Demir AY
    Clin Chem Lab Med; 2012 Nov; 50(11):1985-92. PubMed ID: 22718643
    [TBL] [Abstract][Full Text] [Related]  