146 related articles for article (PubMed ID: 24352863)
1. Optimizing needle direction during transjugular liver biopsy provides superior biopsy specimens.
Clark TW; McCann JW; Salsamendi J; Dowd MF; Hajdu CH
Cardiovasc Intervent Radiol; 2014 Dec; 37(6):1540-5. PubMed ID: 24352863
[TBL] [Abstract][Full Text] [Related]
2. Comparison of a new aspiration needle device and the Quick-Core biopsy needle for transjugular liver biopsy.
Ishikawa T; Kamimura H; Tsuchiya A; Togashi T; Watanabe K; Seki K; Ohta H; Yoshida T; Ishihara N; Kamimura T
World J Gastroenterol; 2006 Oct; 12(39):6339-42. PubMed ID: 17072958
[TBL] [Abstract][Full Text] [Related]
3. Transjugular liver biopsy: how good is it for accurate histological interpretation?
Cholongitas E; Quaglia A; Samonakis D; Senzolo M; Triantos C; Patch D; Leandro G; Dhillon AP; Burroughs AK
Gut; 2006 Dec; 55(12):1789-94. PubMed ID: 16636018
[TBL] [Abstract][Full Text] [Related]
4. A comparison of four- versus three-pass transjugular biopsy using a 19-G Tru-Cut needle and a randomized study using a cassette to prevent biopsy fragmentation.
Vibhakorn S; Cholongitas E; Kalambokis G; Manousou P; Quaglia A; Marelli L; Senzolo M; Patch D; Dhillon A; Burroughs AK
Cardiovasc Intervent Radiol; 2009 May; 32(3):508-13. PubMed ID: 18704569
[TBL] [Abstract][Full Text] [Related]
5. A comparison of transjugular and plugged-percutaneous liver biopsy in patients with contraindications to ordinary percutaneous liver biopsy and an "in-house" protocol for selecting the procedure of choice.
Atar E; Ben Ari Z; Bachar GN; Amlinski Y; Neyman C; Knizhnik M; Litvin S; Schmilovitz-Weiss H; Shapiro R; Bruckhaimer E; Tur-Kaspa R; Belenky A
Cardiovasc Intervent Radiol; 2010 Jun; 33(3):560-4. PubMed ID: 19908088
[TBL] [Abstract][Full Text] [Related]
6. Liver fibrosis: how many samples in transjugular liver biopsy are sufficient? Histological vs. clinical value.
Wolska-Krawczyk M; Krawczyk M; Katoh M; Grünhage F; Schmitt K; Bohle RM; Lammert F; Buecker A
Abdom Imaging; 2013 Jun; 38(3):461-4. PubMed ID: 22801751
[TBL] [Abstract][Full Text] [Related]
7. Transjugular biopsy of the liver in pediatric and adult patients using an 18-gauge automated core biopsy needle: a retrospective review of 410 consecutive procedures.
Smith TP; Presson TL; Heneghan MA; Ryan JM
AJR Am J Roentgenol; 2003 Jan; 180(1):167-72. PubMed ID: 12490497
[TBL] [Abstract][Full Text] [Related]
8. Comparison of the diagnostic quality of aspiration and core-biopsy needles for transjugular liver biopsy.
Stift J; Semmler G; Wöran K; Simbrunner B; Scheiner B; Schwabl P; Paternostro R; Pinter M; Stättermayer AF; Meischl T; Beer A; Trauner M; Mandorfer M; Reiberger T
Dig Liver Dis; 2020 Dec; 52(12):1473-1479. PubMed ID: 32928675
[TBL] [Abstract][Full Text] [Related]
9. Development of a permanently controllable rotating biopsy device, part II: Competitive in-vitro testing of a cannula-like prototype compared to established end-cut and side-notch biopsy devices.
Schaefer PJ; Kurz B; Schaefer FK; Hedderich J; Strutz A; Heller M; Jahnke T
Rofo; 2010 Jan; 182(1):58-65. PubMed ID: 19859867
[TBL] [Abstract][Full Text] [Related]
10. Transjugular liver biopsy: modified Ross transseptal needle versus quick-core biopsy needle.
Choo SW; Do YS; Park KB; Kim SH; Han YH; Choo I
Abdom Imaging; 2000; 25(5):483-5. PubMed ID: 10931981
[TBL] [Abstract][Full Text] [Related]
11. Transjugular liver biopsy in pediatric patients with left split liver transplantation and severe coagulation impairment.
Miraglia R; Maruzzelli L; Spada M; Riva S; Luca A; Gridelli B
Pediatr Transplant; 2012 Feb; 16(1):58-62. PubMed ID: 22081991
[TBL] [Abstract][Full Text] [Related]
12. Transjugular liver biopsy--indications, adequacy, quality of specimens, and complications--a systematic review.
Kalambokis G; Manousou P; Vibhakorn S; Marelli L; Cholongitas E; Senzolo M; Patch D; Burroughs AK
J Hepatol; 2007 Aug; 47(2):284-94. PubMed ID: 17561303
[TBL] [Abstract][Full Text] [Related]
13. Transjugular liver biopsy with an automated device.
Kardache M; Soyer P; Boudiaf M; Cochand-Priollet B; Pelage JP; Rymer R
Radiology; 1997 Aug; 204(2):369-72. PubMed ID: 9240522
[TBL] [Abstract][Full Text] [Related]
14. Transjugular renal biopsy: our experience and technical considerations.
See TC; Thompson BC; Howie AJ; Karamshi M; Papadopoulou AM; Davies N; Tibballs J
Cardiovasc Intervent Radiol; 2008; 31(5):906-18. PubMed ID: 18266029
[TBL] [Abstract][Full Text] [Related]
15. Comparison of Transjugular Liver Biopsy and Percutaneous Liver Biopsy With Tract Embolization in Pediatric Patients.
Tulin-Silver S; Obi C; Kothary N; Lungren MP
J Pediatr Gastroenterol Nutr; 2018 Aug; 67(2):180-184. PubMed ID: 29509634
[TBL] [Abstract][Full Text] [Related]
16. Transjugular liver biopsy.
Ble M; Procopet B; Miquel R; Hernandez-Gea V; García-Pagán JC
Clin Liver Dis; 2014 Nov; 18(4):767-78. PubMed ID: 25438282
[TBL] [Abstract][Full Text] [Related]
17. Effect of needle gauge and lobe laterality on parenchymal liver biopsy outcome: a retrospective analysis.
Vijayaraghavan GR; Vedantham S; Rangan V; Karam A; Zheng L; Roychowdhury A; Hussain S
Abdom Imaging; 2015 Jun; 40(5):1223-9. PubMed ID: 25367814
[TBL] [Abstract][Full Text] [Related]
18. Single-institution results of image-guided nonplugged percutaneous versus transjugular liver biopsy.
Hardman RL; Perrich KD; Silas AM
Cardiovasc Intervent Radiol; 2011 Apr; 34(2):369-75. PubMed ID: 20963589
[TBL] [Abstract][Full Text] [Related]
19. [Transjugular liver biopsy: retrospective study performed on 71 patients].
Quevedo E; Tan J; Araujo G; Morales H; Távara F
Rev Gastroenterol Peru; 2003; 23(4):254-8. PubMed ID: 14716419
[TBL] [Abstract][Full Text] [Related]
20. Contribution of transjugular liver biopsy in patients with the clinical presentation of acute liver failure.
Miraglia R; Luca A; Gruttadauria S; Minervini MI; Vizzini G; Arcadipane A; Gridelli B
Cardiovasc Intervent Radiol; 2006; 29(6):1008-10. PubMed ID: 16967214
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]