These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 24352863)

  • 41. A systematic review of the quality of liver biopsy specimens.
    Cholongitas E; Senzolo M; Standish R; Marelli L; Quaglia A; Patch D; Dhillon AP; Burroughs AK
    Am J Clin Pathol; 2006 May; 125(5):710-21. PubMed ID: 16707372
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Renal biopsy: comparative yield of cranial versus caudal needle trajectory. An ex vivo analysis.
    Karam AR; Vijayaraghavan G; Khan A; Ustun B; Hussain S
    Nephrology (Carlton); 2013 Apr; 18(4):304-6. PubMed ID: 23414122
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Transjugular Liver Biopsy in Patients with Liver Transplantation: Comparison of Quick-Core Biopsy and Forceps Biopsy.
    Kim GH; Gwon DI; Ko GY; Sung KB
    Cardiovasc Intervent Radiol; 2021 Apr; 44(4):574-579. PubMed ID: 33398595
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Image-guided automated core biopsies of the breast, chest, abdomen, and pelvis.
    Burbank F; Kaye K; Belville J; Ekuan J; Blumenfeld M
    Radiology; 1994 Apr; 191(1):165-71. PubMed ID: 8134564
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The utility of ultrasound guidance in transjugular liver biopsy: our experience.
    Sebastian B; Singhal S; Botcha S; Madhurkar R; Thiruchunapalli D; Uthappa MC
    Abdom Radiol (NY); 2019 Feb; 44(2):749-755. PubMed ID: 30132093
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Safety, Feasibility, Yield, Diagnostic and Prognostic Implications of Transjugular Liver Biopsy in Children and Adolescents.
    Lal BB; Sood V; Rastogi A; Mukund A; Khanna R; Sharma MK; Alam S
    J Pediatr Gastroenterol Nutr; 2021 Nov; 73(5):e109-e114. PubMed ID: 34310440
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Adequacy and complications of CT-guided percutaneous biopsy: a study of 334 cases in Srinagarind Hospital.
    Laopaiboon V; Aphinives C; Suporntreetriped K
    J Med Assoc Thai; 2009 Jul; 92(7):939-46. PubMed ID: 19626814
    [TBL] [Abstract][Full Text] [Related]  

  • 48. A combined biopsy-plugging device based on the Menghini- or Trucut needle for percutaneous liver biopsy: clinical experience.
    Judmaier G; Vogel W; Dinges HP; Zatloukal K
    Z Gastroenterol; 1993 Oct; 31(10):614-6. PubMed ID: 8256477
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Ultrasound-guided non-targeted liver core biopsy: comparison of the efficacy of two different core needle biopsy systems using an ex-vivo animal model and retrospective review of clinical experience.
    Ho LM; Pendse AA; Ronald J; Luciano M; Marin D; Jaffe TA; Nelson RC
    Clin Imaging; 2020 May; 61():36-42. PubMed ID: 31954350
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Role of transjugular liver biopsy in the diagnostic and therapeutic management of patients with severe liver disease.
    Esposito AA; Nicolini A; Meregaglia D; Sangiovanni A; Biondetti P
    Radiol Med; 2008 Oct; 113(7):1008-17. PubMed ID: 18781282
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Transjugular Liver Biopsy Following Left Lobe or Lateral Segment Transplantation in Pediatric Patients.
    Tran DK; Ko GY; Sung KB; Gwon DI
    Cardiovasc Intervent Radiol; 2019 Nov; 42(11):1545-1550. PubMed ID: 31385004
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Transjugular liver biopsy and hepatic venous pressure gradient measurement in patients with and without liver cirrhosis.
    Eichholz JC; Kirstein MM; Book T; Wedemeyer H; Voigtländer T
    Eur J Gastroenterol Hepatol; 2021 Dec; 33(12):1582-1587. PubMed ID: 32925497
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Utility and Safety of Transjugular Liver Biopsy in Children.
    Maji P; Malik R; Madhusudhan KS; Sharma S
    Indian J Pediatr; 2021 Jul; 88(7):709-711. PubMed ID: 33533007
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Transjugular biopsy results in the transplanted liver: comparison of two surgical hepatic venous anastomotic configurations in 269 consecutive biopsies over a 14-year period.
    Miller MJ; Smith TP; Kuo PC; Hirasaki KK; Suhocki PV
    J Vasc Interv Radiol; 2010 Apr; 21(4):508-14. PubMed ID: 20189830
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Transjugular liver biopsy in 52 patients with an automated Trucut-type needle.
    De Hoyos A; Loredo ML; Martínez-Ríos MA; Gil MR; Kuri J; Cárdenas M
    Dig Dis Sci; 1999 Jan; 44(1):177-80. PubMed ID: 9952240
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Endoscopic Ultrasound-Guided, Percutaneous, and Transjugular Liver Biopsy: A Comparative Systematic Review and Meta-Analysis.
    McCarty TR; Bazarbashi AN; Njei B; Ryou M; Aslanian HR; Muniraj T
    Clin Endosc; 2020 Sep; 53(5):583-593. PubMed ID: 33027584
    [TBL] [Abstract][Full Text] [Related]  

  • 57. [Diagnostic value of transjugular liver biopsy in liver transplant recipients].
    Romero M; Bañares R; Salcedo M; Alvarez E; Peligros I; Clemente G; Cos E
    Gastroenterol Hepatol; 1999 Dec; 22(10):493-6. PubMed ID: 10650662
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Predictive value of specimen radiography for core needle biopsy of noncalcified breast masses.
    Berg WA; Jaeger B; Campassi C; Kumar D
    AJR Am J Roentgenol; 1998 Dec; 171(6):1671-8. PubMed ID: 9843311
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Transjugular liver biopsy with use of the shark jaw needle: diagnostic yield, complications, and cost-effectiveness.
    Psooy BJ; Clark TW; Beecroft JR; Malatjalian D
    J Vasc Interv Radiol; 2001 Jan; 12(1):61-5. PubMed ID: 11200355
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Transjugular liver biopsy.
    McAfee JH; Keeffe EB; Lee RG; Rösch J
    Hepatology; 1992 Apr; 15(4):726-32. PubMed ID: 1551649
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.