These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

220 related articles for article (PubMed ID: 24356164)

  • 1. Time-delay when updating infusion rates in the Graseby 3400 pump results in reduced drug delivery.
    Sarraf E; Mandel JE
    Anesth Analg; 2014 Jan; 118(1):145-50. PubMed ID: 24356164
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of syringe size on the performance of infusion pumps at low flow rates.
    Schmidt N; Saez C; Seri I; Maturana A
    Pediatr Crit Care Med; 2010 Mar; 11(2):282-6. PubMed ID: 19935442
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Novel Pump Control Technology Accelerates Drug Delivery Onset in a Model of Pediatric Drug Infusion.
    Parker MJ; Lovich MA; Tsao AC; Deng H; Houle T; Peterfreund RA
    Anesth Analg; 2017 Apr; 124(4):1129-1134. PubMed ID: 28181934
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Computer control of drug delivery by continuous intravenous infusion: bridging the gap between intended and actual drug delivery.
    Parker MJ; Lovich MA; Tsao AC; Wei AE; Wakim MG; Maslov MY; Tsukada H; Peterfreund RA
    Anesthesiology; 2015 Mar; 122(3):647-58. PubMed ID: 25419684
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An analysis of drug delivery dynamics via a pediatric central venous infusion system: quantification of delays in achieving intended doses.
    Bartels K; Moss DR; Peterfreund RA
    Anesth Analg; 2009 Oct; 109(4):1156-61. PubMed ID: 19762743
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Flow rate, syringe size and architecture are critical to start-up performance of syringe pumps.
    Neff SB; Neff TA; Gerber S; Weiss MM
    Eur J Anaesthesiol; 2007 Jul; 24(7):602-8. PubMed ID: 17261217
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Start-up delays of infusion syringe pumps.
    Neff T; Fischer J; Fehr S; Baenziger O; Weiss M
    Paediatr Anaesth; 2001; 11(5):561-5. PubMed ID: 11696120
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a novel flow-controlled syringe infusion pump for precise and continuous drug delivery at low flow rates: a laboratory study.
    Batliner M; Weiss M; Dual SA; Grass B; Meboldt M; Schmid Daners M
    Anaesthesia; 2019 Nov; 74(11):1425-1431. PubMed ID: 31373391
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Infusion pump delivers over-dosage of propofol as a result of missing syringe support.
    Koch C; Hollister C; Breen PH
    Anesth Analg; 2006 Apr; 102(4):1154-6. PubMed ID: 16551915
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Syringe Pump Performance Maintained with IV Filter Use During Low Flow Rate Delivery for Pediatric Patients.
    Chau DF; Vasilopoulos T; Schoepf M; Zhang C; Fahy BG
    Anesth Analg; 2016 Sep; 123(3):705-14. PubMed ID: 27074895
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Factors altering low-flow drug delivery using syringe pumps: Consequences on vasoactive drug infusion in preterm infant].
    Rakza T; Richard A; Lelieur AC; Villaume I; Huyghe A; Nempont C; Storme L
    Arch Pediatr; 2005 May; 12(5):548-54. PubMed ID: 15885544
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Syringe pumps and start-up time: ensuring safe practice.
    Amoore J; Dewar D; Ingram P; Lowe D
    Nurs Stand; 2001 Jan 10-16; 15(17):43-5. PubMed ID: 12211850
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Syringe size and flow rate affect drug delivery from syringe pumps.
    Weiss M; Hug MI; Neff T; Fischer J
    Can J Anaesth; 2000 Oct; 47(10):1031-5. PubMed ID: 11032282
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accurate continuous drug delivery at low infusion rate with a novel microvolumetric infusion pump (MVIP): pump design, evaluation and comparison to the current standard.
    Weiss M; Gerber S; Füchslin RM; Neff TA
    Anaesthesia; 2004 Nov; 59(11):1133-7. PubMed ID: 15479325
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Medication and volume delivery by gravity-driven micro-drip intravenous infusion: potential variations during "wide-open" flow.
    Pierce ET; Kumar V; Zheng H; Peterfreund RA
    Anesth Analg; 2013 Mar; 116(3):614-8. PubMed ID: 23400996
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In-line filter included into the syringe infusion pump assembly reduces flow irregularities.
    Brotschi B; Grass B; Weiss M; Doell C; Bernet V
    Intensive Care Med; 2012 Mar; 38(3):518-22. PubMed ID: 22237747
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Connecting multiple low-flow intravenous infusions in the newborn: problems and possible solutions.
    Levi DS; Peterson N; Shah SD; Rakholia B; Haught A; Carman G
    Pediatr Crit Care Med; 2010 Mar; 11(2):275-81. PubMed ID: 20068501
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy of drug infusion pumps under computer control.
    Connor SB; Quill TJ; Jacobs JR
    IEEE Trans Biomed Eng; 1992 Sep; 39(9):980-2. PubMed ID: 1473827
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An in vitro evaluation of infusion methods using a syringe pump to improve noradrenaline administration.
    Genay S; Décaudin B; Scoccia S; Barthélémy C; Debaene B; Lebuffe G; Odou P
    Acta Anaesthesiol Scand; 2015 Feb; 59(2):197-204. PubMed ID: 25476454
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Lag times to steady state drug delivery by continuous intravenous infusion: direct comparison of peristaltic and syringe pump performance identifies contributions from infusion system dead volume and pump startup characteristics.
    Gibson LE; Knudsen AS; Arney D; Deng H; Sims NM; Peterfreund RA
    J Clin Monit Comput; 2022 Oct; 36(5):1489-1498. PubMed ID: 34878612
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.