These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
173 related articles for article (PubMed ID: 24363076)
1. Efficacy of antibacterial-loaded coating in an in vivo model of acutely highly contaminated implant. Giavaresi G; Meani E; Sartori M; Ferrari A; Bellini D; Sacchetta AC; Meraner J; Sambri A; Vocale C; Sambri V; Fini M; Romanò CL Int Orthop; 2014 Jul; 38(7):1505-12. PubMed ID: 24363076 [TBL] [Abstract][Full Text] [Related]
3. 3D-printed porous titanium rods equipped with vancomycin-loaded hydrogels and polycaprolactone membranes for intelligent antibacterial drug release. Ma Z; Zhao Y; Xu Z; Zhang Y; Han Y; Jiang H; Sun P; Feng W Sci Rep; 2024 Sep; 14(1):21749. PubMed ID: 39294268 [TBL] [Abstract][Full Text] [Related]
4. Vitamin E Phosphate Coating Stimulates Bone Deposition in Implant-related Infections in a Rat Model. Lovati AB; Bottagisio M; Maraldi S; Violatto MB; Bortolin M; De Vecchi E; Bigini P; Drago L; Romanò CL Clin Orthop Relat Res; 2018 Jun; 476(6):1324-1338. PubMed ID: 29771856 [TBL] [Abstract][Full Text] [Related]
5. Titanium implant coating based on dopamine-functionalized sulphated hyaluronic acid: in vivo assessment of biocompatibility and antibacterial efficacy. Guarise C; Maglio M; Sartori M; Galesso D; Barbera C; Pavan M; Martini L; Giavaresi G; Sambri V; Fini M Mater Sci Eng C Mater Biol Appl; 2021 Sep; 128():112286. PubMed ID: 34474837 [TBL] [Abstract][Full Text] [Related]
6. Local gentamicin delivery from resorbable viscous hydrogels is therapeutically effective. Overstreet D; McLaren A; Calara F; Vernon B; McLemore R Clin Orthop Relat Res; 2015 Jan; 473(1):337-47. PubMed ID: 25227556 [TBL] [Abstract][Full Text] [Related]
7. Effect on infection resistance of a local antiseptic and antibiotic coating on osteosynthesis implants: an in vitro and in vivo study. Kälicke T; Schierholz J; Schlegel U; Frangen TM; Köller M; Printzen G; Seybold D; Klöckner S; Muhr G; Arens S J Orthop Res; 2006 Aug; 24(8):1622-40. PubMed ID: 16779814 [TBL] [Abstract][Full Text] [Related]
9. In Vivo Efficacy of a "Smart" Antimicrobial Implant Coating. Stavrakis AI; Zhu S; Hegde V; Loftin AH; Ashbaugh AG; Niska JA; Miller LS; Segura T; Bernthal NM J Bone Joint Surg Am; 2016 Jul; 98(14):1183-9. PubMed ID: 27440566 [TBL] [Abstract][Full Text] [Related]
10. Treatment of implant-related methicillin-resistant Staphylococcus aureus osteomyelitis with vancomycin-loaded VK100 silicone cement: An experimental study in rats. Neyisci C; Erdem Y; Bilekli AB; Demiralp B; Kose O; Bek D; Korkusuz F; Kankilic B J Orthop Surg (Hong Kong); 2018; 26(1):2309499017754093. PubMed ID: 29382296 [TBL] [Abstract][Full Text] [Related]
11. Cathodic Voltage-controlled Electrical Stimulation Plus Prolonged Vancomycin Reduce Bacterial Burden of a Titanium Implant-associated Infection in a Rodent Model. Nodzo SR; Tobias M; Ahn R; Hansen L; Luke-Marshall NR; Howard C; Wild L; Campagnari AA; Ehrensberger MT Clin Orthop Relat Res; 2016 Jul; 474(7):1668-75. PubMed ID: 26801677 [TBL] [Abstract][Full Text] [Related]
12. A biodegradable gentamicin-hydroxyapatite-coating for infection prophylaxis in cementless hip prostheses. Neut D; Dijkstra RJ; Thompson JI; Kavanagh C; van der Mei HC; Busscher HJ Eur Cell Mater; 2015 Jan; 29():42-55; discussion 55-6. PubMed ID: 25552428 [TBL] [Abstract][Full Text] [Related]
13. Intraoperative Vancomycin Powder Reduces Staphylococcus aureus Surgical Site Infections and Biofilm Formation on Fixation Implants in a Rabbit Model. Hovis JP; Montalvo R; Marinos D; Joshi M; Shirtliff ME; OʼToole RV; Manson TT J Orthop Trauma; 2018 May; 32(5):263-268. PubMed ID: 29401093 [TBL] [Abstract][Full Text] [Related]
14. Vancomycin-Loaded Polymethylmethacrylate Spacers Fail to Eradicate Periprosthetic Joint Infection in a Clinically Representative Mouse Model. Carli AV; Bhimani S; Yang X; de Mesy Bentley KL; Ross FP; Bostrom MPG J Bone Joint Surg Am; 2018 Jun; 100(11):e76. PubMed ID: 29870449 [TBL] [Abstract][Full Text] [Related]
15. Implant stability in the treatment of MRSA bone implant infections with linezolid versus vancomycin in a rabbit model. Schroeder K; Simank HG; Lorenz H; Swoboda S; Geiss HK; Helbig L J Orthop Res; 2012 Feb; 30(2):190-5. PubMed ID: 21815204 [TBL] [Abstract][Full Text] [Related]
16. Is Implant Coating With Tyrosol- and Antibiotic-loaded Hydrogel Effective in Reducing Cutibacterium (Propionibacterium) acnes Biofilm Formation? A Preliminary In Vitro Study. Tsikopoulos K; Bidossi A; Drago L; Petrenyov DR; Givissis P; Mavridis D; Papaioannidou P Clin Orthop Relat Res; 2019 Jul; 477(7):1736-1746. PubMed ID: 31135555 [TBL] [Abstract][Full Text] [Related]
17. The Use of a Novel Antimicrobial Implant Coating In Vivo to Prevent Spinal Implant Infection. Hegde V; Park HY; Dworsky E; Zoller SD; Xi W; Johansen DO; Loftin AH; Hamad CD; Segura T; Bernthal NM Spine (Phila Pa 1976); 2020 Mar; 45(6):E305-E311. PubMed ID: 31593059 [TBL] [Abstract][Full Text] [Related]
18. A silver ion-doped calcium phosphate-based ceramic nanopowder-coated prosthesis increased infection resistance. Kose N; Otuzbir A; Pekşen C; Kiremitçi A; Doğan A Clin Orthop Relat Res; 2013 Aug; 471(8):2532-9. PubMed ID: 23463287 [TBL] [Abstract][Full Text] [Related]
19. Two-stage cementless hip revision for peri-prosthetic infection with an antibacterial hydrogel coating: results of a comparative series. Zagra L; Gallazzi E; Romanò D; Scarponi S; Romanò C Int Orthop; 2019 Jan; 43(1):111-115. PubMed ID: 30374639 [TBL] [Abstract][Full Text] [Related]