These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
145 related articles for article (PubMed ID: 24366558)
21. A comparison of four radionuclide dose calibrators using various radionuclides and measurement geometries clinically used in nuclear medicine. Bauwens M; Pooters I; Cobben R; Visser M; Schnerr R; Mottaghy F; Wildberger J; Wierts R Phys Med; 2019 Apr; 60():14-21. PubMed ID: 31000075 [TBL] [Abstract][Full Text] [Related]
22. Calibration of the Capintec CRC-712M dose calibrator for (18)F. Mo L; Reinhard MI; Davies JB; Alexiev D; Baldock C Appl Radiat Isot; 2006 Apr; 64(4):485-9. PubMed ID: 16293417 [TBL] [Abstract][Full Text] [Related]
23. Dedicated phantom tools using traceable Okamoto M; Hasegawa T; Oda K; Miyatake H; Kikuchi K; Inoue Y; Satoh Y; Inaoka Y; Kawamoto M; Shima K; Kanbayashi K; Yoshii M; Kanno T; Wagatsuma K; Hashimoto M Radiol Phys Technol; 2023 Mar; 16(1):49-56. PubMed ID: 36622563 [TBL] [Abstract][Full Text] [Related]
24. Assessing the absolute quantitative accuracy of Positron Emission Tomography for Cu-64 using traceable calibrated phantoms. Zimmerman BE; Bergeron DE; Edgerton JP Appl Radiat Isot; 2018 Apr; 134():68-73. PubMed ID: 28974328 [TBL] [Abstract][Full Text] [Related]
25. Determination of the Re-188 Calibration Number for the Capintec CRC- 25PET Dose Calibrator. Klenner MA; Poole A Curr Radiopharm; 2023; 16(4):292-299. PubMed ID: 37138431 [TBL] [Abstract][Full Text] [Related]
26. Quantitative online isolation of ⁶⁸Ge from ⁶⁸Ge/⁶⁸Ga generator eluates for purification and immediate quality control of breakthrough. Eppard E; Loktionova NS; Rösch F Appl Radiat Isot; 2013 Dec; 82():45-8. PubMed ID: 23948310 [TBL] [Abstract][Full Text] [Related]
27. Two determinations of the Ge-68 half-life. Bergeron DE; Cessna JT; Zimmerman BE Appl Radiat Isot; 2018 Apr; 134():416-420. PubMed ID: 29100721 [TBL] [Abstract][Full Text] [Related]
28. Performance assessment of a NaI(Tl) gamma counter for PET applications with methods for improved quantitative accuracy and greater standardization. Lodge MA; Holt DP; Kinahan PE; Wong DF; Wahl RL EJNMMI Phys; 2015 May; 2():. PubMed ID: 26046011 [TBL] [Abstract][Full Text] [Related]
29. [Comparison of activity expression between PET using 68Ge-68Ga line source attenuation correction and PET-CT using CT attenuation correction: impact on emission images]. Hayashi E; Iwase M; Kojima S; Nishio M Nihon Hoshasen Gijutsu Gakkai Zasshi; 2006 Jun; 62(6):832-9. PubMed ID: 16799411 [TBL] [Abstract][Full Text] [Related]
30. ⁶⁸Ge content quality control of ⁶⁸Ge/⁶⁸Ga-generator eluates and ⁶⁸Ga radiopharmaceuticals--a protocol for determining the ⁶⁸Ge content using thin-layer chromatography. Eppard E; Loktionova NS; Rösch F Appl Radiat Isot; 2014 Sep; 91():92-6. PubMed ID: 24922553 [TBL] [Abstract][Full Text] [Related]
31. Measurement of dose-rate constant for 103Pd seeds with air kerma strength calibration based upon a primary national standard. Nath R; Yue N; Shahnazi K; Bongiorni PJ Med Phys; 2000 Apr; 27(4):655-8. PubMed ID: 10798685 [TBL] [Abstract][Full Text] [Related]
32. Innovative methodology for intercomparison of radionuclide calibrators using short half-life in situ prepared radioactive sources. Oliveira PA; Santos JA Med Phys; 2014 Jul; 41(7):072507. PubMed ID: 24989410 [TBL] [Abstract][Full Text] [Related]
34. A practical method of determining cross-calibration factors of PET scanners by moving a point-like (22)Na radioactive source. Hasegawa T; Oda K; Wada Y; Sato Y; Yamada T; Yoshida E; Murayama H; Saito K; Takeda T; Kikuchi K Ann Nucl Med; 2010 Nov; 24(9):655-61. PubMed ID: 20700667 [TBL] [Abstract][Full Text] [Related]
35. Accurate dose calibrator activity measurement of 90Y-ibritumomab tiuxetan. Siegel JA; Zimmerman BE; Kodimer K; Dell MA; Simon WE J Nucl Med; 2004 Mar; 45(3):450-4. PubMed ID: 15001686 [TBL] [Abstract][Full Text] [Related]
36. The (68)Ge phantom-based FDG-PET site qualification program for clinical trials adopted by FIL (Italian Foundation on Lymphoma). Chauvie S; Bergesio F; Fioroni F; Brambilla M; Biggi A; Versari A; Guerra L; Storto G; Musto P; Luminari S; Cabras MG; Balzarotti M; Rigacci L; Martelli M; Vitolo U; Federico M; Gallamini A Phys Med; 2016 May; 32(5):651-6. PubMed ID: 27133138 [TBL] [Abstract][Full Text] [Related]
37. Intermetallic cobalt-gallium targets for production of germanium radioisotopes. Kutyreff CJ; Barnhart TE; Lo YH; Happel S; Nickles RJ; Ellison PA; Aluicio-Sarduy E; Engle JW Appl Radiat Isot; 2022 Sep; 187():110307. PubMed ID: 35696750 [TBL] [Abstract][Full Text] [Related]
38. Determination of the efficiency of commercially available dose calibrators for beta-emitters. Valley JF; Bulling S; Leresche M; Wastiel C J Nucl Med Technol; 2003 Mar; 31(1):27-32. PubMed ID: 12624125 [TBL] [Abstract][Full Text] [Related]