BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 24373139)

  • 1. The pneumatic tube system does not affect complete blood count results; a validation study at a tertiary care hospital.
    Al-Riyami AZ; Al-Khabori M; Al-Hadhrami RM; Al-Azwani IS; Davis HM; Al-Farsi KS; Alkindi SS; Daar SF
    Int J Lab Hematol; 2014 Oct; 36(5):514-20. PubMed ID: 24373139
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of pneumatic tube transport on T lymphocyte subsets analysis.
    Gossez M; Poitevin-Later F; Demaret J; Jallades L; Venet F; Malcus C; Monneret G
    Cytometry B Clin Cytom; 2015; 88(6):371-4. PubMed ID: 25665181
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Preanalytical influence of pneumatic tube delivery system on results of routine biochemistry and haematology analysis.
    Petit M; Mine L; Pascreau T; Brouzes C; Majoux S; Borgel D; Beaudeux JL; Lasne D; Hennequin C
    Ann Biol Clin (Paris); 2017 Dec; 75(6):703-712. PubMed ID: 29043982
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Effect of Pneumatic Tube Systems on the Hemolysis of Biochemistry Blood Samples.
    Cakirca G; Erdal H
    J Emerg Nurs; 2017 May; 43(3):255-258. PubMed ID: 28359708
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of acceleration forces during transport through a pneumatic tube system on ROTEM® analysis.
    Amann G; Zehntner C; Marti F; Colucci G
    Clin Chem Lab Med; 2012 Mar; 50(8):1335-42. PubMed ID: 22868797
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The Effects of Sample Transport by Pneumatic Tube System on Routine Hematology and Coagulation Tests.
    Subbarayan D; Choccalingam C; Lakshmi CKA
    Adv Hematol; 2018; 2018():6940152. PubMed ID: 30079089
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Impact of a pneumatic tube system transport on hemostasis parameters measurement: the experiment of Cochin universitary hospital (AP-HP, Paris, France).
    Calmette L; Ibrahim F; Gouin I; Horellou MH; Mazoyer É; Fontenay M; Flaujac C
    Ann Biol Clin (Paris); 2017 Feb; 75(1):93-100. PubMed ID: 28132949
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of clinical data and acceleration profiles to validate pneumatic transportation systems.
    Gils C; Broell F; Vinholt PJ; Nielsen C; Nybo M
    Clin Chem Lab Med; 2020 Mar; 58(4):560-568. PubMed ID: 31804954
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Verification of complete blood cell count (CBC) data from heparinized blood gas samples].
    Sakoguchi T; Fujii S; Inuzumi K; Kaminoh Y; Hirose M; Masaki M; Koshiba M
    Rinsho Byori; 2014 Feb; 62(2):139-46. PubMed ID: 24800489
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pre-analytical effects of pneumatic tube system transport on routine haematology and coagulation tests, global coagulation assays and platelet function assays.
    Le Quellec S; Paris M; Nougier C; Sobas F; Rugeri L; Girard S; Bordet JC; Négrier C; Dargaud Y
    Thromb Res; 2017 May; 153():7-13. PubMed ID: 28292729
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Laboratory-based ROTEM(®) analysis: implementing pneumatic tube transport and real-time graphic transmission.
    Colucci G; Giabbani E; Barizzi G; Urwyler N; Alberio L
    Int J Lab Hematol; 2011 Aug; 33(4):441-6. PubMed ID: 21382181
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of pneumatic tube system with manual transport for routine chemistry, hematology, coagulation and blood gas tests.
    Pupek A; Matthewson B; Whitman E; Fullarton R; Chen Y
    Clin Chem Lab Med; 2017 Aug; 55(10):1537-1544. PubMed ID: 28432841
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of complete blood counts in samples obtained from healthy dogs and cats by use of standard and microsample blood collection tubes.
    Whittemore JC; Flatland B
    J Am Vet Med Assoc; 2010 Aug; 237(3):281-7. PubMed ID: 20673108
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pneumatic transport exacerbates interference of room air contamination in blood gas samples.
    Astles JR; Lubarsky D; Loun B; Sedor FA; Toffaletti JG
    Arch Pathol Lab Med; 1996 Jul; 120(7):642-7. PubMed ID: 8757468
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of one directional pneumatic tube system on routine hematology and chemistry parameters; A validation study at a tertiary care hospital.
    Lee AJ; Suk Suh H; Jeon CH; Kim SG
    Pract Lab Med; 2017 Dec; 9():12-17. PubMed ID: 29034301
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pneumatic tube system transport and false hyperkalemia related to leukocytosis: a retrospective analysis.
    Grzych G; Roland E; Lezier D; Beauvais D; Maboudou P; Lippi G
    Ann Biol Clin (Paris); 2019 Jun; 77(3):281-286. PubMed ID: 31115339
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of pneumatic tube delivery system on laboratory results.
    Makhlouf R; Fendri S; Jallouli D; Labiadh Z; Fritis L; Chaabouni K; Elleuch A; Ayadi FM
    Ann Clin Biochem; 2024 May; 61(3):210-217. PubMed ID: 37921518
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of the pneumatic tube system for transportation of packed red cell units.
    Dhar S; Basu S; Chakraborty S; Sinha S
    Asian J Transfus Sci; 2015; 9(2):195-8. PubMed ID: 26420944
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pneumatic tube system induced haemolysis: assessing sample type susceptibility to haemolysis.
    Sodi R; Darn SM; Stott A
    Ann Clin Biochem; 2004 May; 41(Pt 3):237-40. PubMed ID: 15117440
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pneumatic tube delivery system for blood samples reduces turnaround times without affecting sample quality.
    Fernandes CM; Worster A; Eva K; Hill S; McCallum C
    J Emerg Nurs; 2006 Apr; 32(2):139-43. PubMed ID: 16580476
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.