These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 24379266)

  • 21. Finite element method analysis of the periodontal ligament in mandibular canine movement with transparent tooth correction treatment.
    Cai Y; Yang X; He B; Yao J
    BMC Oral Health; 2015 Sep; 15():106. PubMed ID: 26337291
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Finite element analysis of equine incisor teeth. Part 2: investigation of stresses and strain energy densities in the periodontal ligament and surrounding bone during tooth movement.
    Schrock P; Lüpke M; Seifert H; Staszyk C
    Vet J; 2013 Dec; 198(3):590-8. PubMed ID: 24252223
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Assessment of the Maximum Amount of Orthodontic Force for PDL in Intact and Reduced Periodontium (Part I).
    Moga RA; Olteanu CD; Botez M; Buru SM
    Int J Environ Res Public Health; 2023 Jan; 20(3):. PubMed ID: 36767254
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Deformation analysis of the periodontium considering the viscoelasticity of the periodontal ligament.
    Qian L; Todo M; Morita Y; Matsushita Y; Koyano K
    Dent Mater; 2009 Oct; 25(10):1285-92. PubMed ID: 19560807
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Influence of alveolar support on stress in periodontal structures.
    Ona M; Wakabayashi N
    J Dent Res; 2006 Dec; 85(12):1087-91. PubMed ID: 17122159
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Numerical study of tension and strain distribution around rat molars].
    Kawarizadeh A; Bourauel C; Götz W; Jäger A
    Biomed Tech (Berl); 2003 Apr; 48(4):90-6. PubMed ID: 12749287
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Experiment and hydro-mechanical coupling simulation study on the human periodontal ligament.
    Wei Z; Yu X; Xu X; Chen X
    Comput Methods Programs Biomed; 2014 Mar; 113(3):749-56. PubMed ID: 24440132
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A validated finite element method study of orthodontic tooth movement in the human subject.
    Jones ML; Hickman J; Middleton J; Knox J; Volp C
    J Orthod; 2001 Mar; 28(1):29-38. PubMed ID: 11254801
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A nonlinear elastic model of the periodontal ligament and its numerical calibration for the study of tooth mobility.
    Pietrzak G; Curnier A; Botsis J; Scherrer S; Wiskott A; Belser U
    Comput Methods Biomech Biomed Engin; 2002 Apr; 5(2):91-100. PubMed ID: 12186719
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Development of a novel intraoral measurement device to determine the biomechanical characteristics of the human periodontal ligament.
    Drolshagen M; Keilig L; Hasan I; Reimann S; Deschner J; Brinkmann KT; Krause R; Favino M; Bourauel C
    J Biomech; 2011 Jul; 44(11):2136-43. PubMed ID: 21679952
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Importance of the variable periodontal ligament geometry for whole tooth mechanical function: A validated numerical study.
    Nikolaus A; Currey JD; Lindtner T; Fleck C; Zaslansky P
    J Mech Behav Biomed Mater; 2017 Mar; 67():61-73. PubMed ID: 27987427
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Mechanical environment change in root, periodontal ligament, and alveolar bone in response to two canine retraction treatment strategies.
    Jiang F; Xia Z; Li S; Eckert G; Chen J
    Orthod Craniofac Res; 2015 Apr; 18 Suppl 1(0 1):29-38. PubMed ID: 25865531
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Moment-to-force ratio, center of rotation, and force level: a finite element study predicting their interdependency for simulated orthodontic loading regimens.
    Cattaneo PM; Dalstra M; Melsen B
    Am J Orthod Dentofacial Orthop; 2008 May; 133(5):681-9. PubMed ID: 18456141
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Three-dimensional modeling and finite element analysis in treatment planning for orthodontic tooth movement.
    Ammar HH; Ngan P; Crout RJ; Mucino VH; Mukdadi OM
    Am J Orthod Dentofacial Orthop; 2011 Jan; 139(1):e59-71. PubMed ID: 21195258
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Stress change of periodontal ligament of the anterior teeth at the stage of space closure in lingual appliances: a 3-dimensional finite element analysis].
    Liu DW; Li J; Guo L; Rong QG; Zhou YH
    Beijing Da Xue Xue Bao Yi Xue Ban; 2018 Feb; 50(1):141-147. PubMed ID: 29483737
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Ideal orthodontic alignment load relationships based on periodontal ligament stress.
    Viecilli RF; Burstone CJ
    Orthod Craniofac Res; 2015 Apr; 18 Suppl 1():180-6. PubMed ID: 25865547
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A finite element model of apical force distribution from orthodontic tooth movement.
    Rudolph DJ; Willes PMG ; Sameshima GT
    Angle Orthod; 2001 Apr; 71(2):127-31. PubMed ID: 11302589
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Digital design and fabrication of simulation model for measuring orthodontic force.
    Liu YF; Zhang PY; Zhang QF; Zhang JX; Chen J
    Biomed Mater Eng; 2014; 24(6):2265-71. PubMed ID: 25226926
    [TBL] [Abstract][Full Text] [Related]  

  • 39. In vivo measurements and numerical analysis of the biomechanical characteristics of the human periodontal ligament.
    Keilig L; Drolshagen M; Tran KL; Hasan I; Reimann S; Deschner J; Brinkmann KT; Krause R; Favino M; Bourauel C
    Ann Anat; 2016 Jul; 206():80-8. PubMed ID: 26395824
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The effects of the periodontal ligament on mandibular stiffness: a study combining finite element analysis and geometric morphometrics.
    Gröning F; Fagan MJ; O'Higgins P
    J Biomech; 2011 Apr; 44(7):1304-12. PubMed ID: 21292267
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.