These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

199 related articles for article (PubMed ID: 24381152)

  • 1. Local verification and assignment of mean normal prothrombin time and International Sensitivity Index values across various instruments: recent experience and outcome from North America.
    Tange JI; Grill D; Koch CD; Ybabez RJ; Krekelberg BJ; Fylling KA; Wiese CR; Baumann NA; Block DR; Karon BS; Chen D; Pruthi RK
    Semin Thromb Hemost; 2014 Feb; 40(1):115-20. PubMed ID: 24381152
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improving the inter-laboratory harmonization of the international normalized ratio (INR): utilizing the concept of transference to estimate and/or validate international sensitivity index (ISI) and mean normal prothrombin time (MNPT) values and/or to eliminate measurement bias.
    Favaloro EJ; McVicker W; Zhang Y; Hamdam S; Huynh M; Peris P; O'Neal M; Hocker N
    Clin Lab Sci; 2012; 25(1):13-25. PubMed ID: 22458045
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison of INRs after local calibration of thromboplastin international sensitivity indexes.
    McGlasson DL
    Clin Lab Sci; 2002; 15(2):91-5. PubMed ID: 12776770
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Time to think outside the box? Prothrombin time, international normalised ratio, international sensitivity index, mean normal prothrombin time and measurement of uncertainty: a novel approach to standardisation.
    Favaloro EJ; Hamdam S; McDonald J; McVicker W; Ule V
    Pathology; 2008 Apr; 40(3):277-87. PubMed ID: 18428048
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimizing the Verification of Mean Normal Prothrombin Time (MNPT) and International Sensitivity Index (ISI) for Accurate Conversion of Prothrombin Time (PT) to International Normalized Ratio (INR).
    Favaloro EJ
    Methods Mol Biol; 2017; 1646():59-74. PubMed ID: 28804818
    [TBL] [Abstract][Full Text] [Related]  

  • 6. How to Generate a More Accurate Laboratory-Based International Normalized Ratio: Solutions to Obtaining or Verifying the Mean Normal Prothrombin Time and International Sensitivity Index.
    Favaloro EJ
    Semin Thromb Hemost; 2019 Feb; 45(1):10-21. PubMed ID: 30134448
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Standardization of the INR: how good is your laboratory's INR and can it be improved?
    Favaloro EJ; Adcock DM
    Semin Thromb Hemost; 2008 Oct; 34(7):593-603. PubMed ID: 19085760
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Improving the harmonisation of the International Normalized Ratio (INR): time to think outside the box?
    Favaloro EJ; McVicker W; Hamdam S; Hocker N
    Clin Chem Lab Med; 2010 Aug; 48(8):1079-90. PubMed ID: 20441474
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of an international sensitivity index of thromboplastin reagents using a WHO thromboplastin as calibrator for plasma spiked with rivaroxaban.
    Harenberg J; Marx S; Krämer R; Giese C; Weiss C
    Blood Coagul Fibrinolysis; 2011 Dec; 22(8):637-41. PubMed ID: 21986465
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Standardization of Prothrombin Time/International Normalized Ratio (PT/INR).
    Dorgalaleh A; Favaloro EJ; Bahraini M; Rad F
    Int J Lab Hematol; 2021 Feb; 43(1):21-28. PubMed ID: 32979036
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of frozen plasma calibrants for enhanced standardization of the international normalized ratio (INR): a multi-center study.
    Adcock DM; Johnston M
    Thromb Haemost; 2002 Jan; 87(1):74-9. PubMed ID: 11848460
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Guidelines on preparation, certification, and use of certified plasmas for ISI calibration and INR determination.
    van den Besselaar AM; Barrowcliffe TW; Houbouyan-Réveillard LL; Jespersen J; Johnston M; Poller L; Tripodi A;
    J Thromb Haemost; 2004 Nov; 2(11):1946-53. PubMed ID: 15550026
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Estimating the measurement uncertainties of the international sensitivity index of 12 thromboplastins through Monte Carlo simulation.
    Lim YK; Kweon OJ; Lee MK; Kim HR
    Thromb Res; 2023 Apr; 224():32-37. PubMed ID: 36812877
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Discrepant sensitivity of thromboplastin reagents to clotting factor levels explored by the prothrombin time in patients on stable oral anticoagulant treatment: impact on the international normalized ratio system.
    Testa S; Morstabilini G; Fattorini A; Galli L; Denti N; D'Angelo A
    Haematologica; 2002 Dec; 87(12):1265-73. PubMed ID: 12495900
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of STA-NeoPTimal, an extraction thromboplastin reagent with ISI close to 1.
    Carta M; Bonente F; Teresa Comberlato M; Pellizzari T; Marotto E; Marzari E; Giavarina D
    Int J Lab Hematol; 2021 Apr; 43(2):311-317. PubMed ID: 33070473
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of three types of automated coagulometers on the international sensitivity index (ISI) of rabbit, human, and recombinant human tissue factor preparations--a multicenter study.
    van den Besselaar AM; Houbouyan LL; Aillaud MF; Denson KW; Johnston M; Kitchen S; Lindahl TL; Marren M; Martinuzzo ME; Droullé C; Tripodi A; Vergnes C
    Thromb Haemost; 1999 Jan; 81(1):66-70. PubMed ID: 9974377
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Standardization of coagulation tests.
    Opartkiattikul N
    Southeast Asian J Trop Med Public Health; 1999; 30 Suppl 3():79-85. PubMed ID: 10926265
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Suggestions and propositions to resolve some issues for standardization of prothrombin time and activated partial thromboplastin time].
    Kagawa K; Fukutake K
    Rinsho Byori; 1999 May; 47(5):431-7. PubMed ID: 10375964
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An International Sensitivity Index (ISI) derived from patients with abnormal liver function improves agreement between INRs determined with different reagents.
    Sermon AM; Smith JM; Maclean R; Kitchen S
    Thromb Haemost; 2010 Apr; 103(4):757-65. PubMed ID: 20174759
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Harmonizing the International Normalized Ratio (INR) : Standardization of Methods and Use of Novel Strategies to Reduce Interlaboratory Variation and Bias.
    Favaloro EJ; McVicker W; Lay M; Ahuja M; Zhang Y; Hamdam S; Hocker N
    Am J Clin Pathol; 2016 Feb; 145(2):191-202. PubMed ID: 26800763
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.