175 related articles for article (PubMed ID: 24387428)
1. Broad-band efficiency calibration of ITER bolometer prototypes using Pt absorbers on SiN membranes.
Meister H; Willmeroth M; Zhang D; Gottwald A; Krumrey M; Scholze F
Rev Sci Instrum; 2013 Dec; 84(12):123501. PubMed ID: 24387428
[TBL] [Abstract][Full Text] [Related]
2. Reliability issues for a bolometer detector for ITER at high operating temperatures.
Meister H; Kannamüller M; Koll J; Pathak A; Penzel F; Trautmann T; Detemple P; Schmitt S; Langer H
Rev Sci Instrum; 2012 Oct; 83(10):10D724. PubMed ID: 23126898
[TBL] [Abstract][Full Text] [Related]
3. Optimization of a bolometer detector for ITER based on Pt absorber on SiN membrane.
Meister H; Eich T; Endstrasser N; Giannone L; Kannamüller M; Kling A; Koll J; Trautmann T; ; Detemple P; Schmitt S
Rev Sci Instrum; 2010 Oct; 81(10):10E132. PubMed ID: 21061487
[TBL] [Abstract][Full Text] [Related]
4. Absolute radiant power measurement for the Au M lines of laser-plasma using a calibrated broadband soft X-ray spectrometer with flat-spectral response.
Troussel P; Villette B; Emprin B; Oudot G; Tassin V; Bridou F; Delmotte F; Krumrey M
Rev Sci Instrum; 2014 Jan; 85(1):013503. PubMed ID: 24517761
[TBL] [Abstract][Full Text] [Related]
5. High-accuracy detector calibration in the 3-1500 eV spectral range at the PTB radiometry laboratory.
Scholze F; Henneken H; Kuschnerus P; Rabus H; Richter M; Ulm G
J Synchrotron Radiat; 1998 May; 5(Pt 3):866-8. PubMed ID: 15263679
[TBL] [Abstract][Full Text] [Related]
6. Quantum efficiency measurement of an x-ray charge-coupled device by means of an x-ray generator monochromatized over the 0.2-1.2 keV spectral region.
Hubert S; Boubault F
Appl Opt; 2018 Oct; 57(28):8228-8235. PubMed ID: 30461772
[TBL] [Abstract][Full Text] [Related]
7. The resistive bolometer for radiated power measurement on EAST.
Duan YM; Hu LQ; Mao ST; Chen KY; Lin SY;
Rev Sci Instrum; 2012 Sep; 83(9):093501. PubMed ID: 23025621
[TBL] [Abstract][Full Text] [Related]
8. On the existence of low-energy photons (<150 keV) in the unflattened x-ray beam from an ordinary radiotherapeutic target in a medical linear accelerator.
Tsechanski A; Krutman Y; Faermann S
Phys Med Biol; 2005 Dec; 50(23):5629-39. PubMed ID: 16306657
[TBL] [Abstract][Full Text] [Related]
9. Reference-free total reflection X-ray fluorescence analysis of semiconductor surfaces with synchrotron radiation.
Beckhoff B; Fliegauf R; Kolbe M; Müller M; Weser J; Ulm G
Anal Chem; 2007 Oct; 79(20):7873-82. PubMed ID: 17880182
[TBL] [Abstract][Full Text] [Related]
10. Measurement of the x-ray mass energy-absorption coefficient of air using 3 keV to 10 keV synchrotron radiation.
Büermann L; Grosswendt B; Kramer HM; Selbach HJ; Gerlach M; Hoffmann M; Krumrey M
Phys Med Biol; 2006 Oct; 51(20):5125-50. PubMed ID: 17019029
[TBL] [Abstract][Full Text] [Related]
11. Radiometric calibration of the telescope and ultraviolet spectrometer SUMER on SOHO.
Hollandt J; Schühle U; Paustian W; Curdt W; Kühne M; Wende B; Wilhelm K
Appl Opt; 1996 Sep; 35(25):5125-33. PubMed ID: 21102947
[TBL] [Abstract][Full Text] [Related]
12. Traceable terahertz power measurement from 1 THz to 5 THz.
Steiger A; Kehrt M; Monte C; Müller R
Opt Express; 2013 Jun; 21(12):14466-73. PubMed ID: 23787634
[TBL] [Abstract][Full Text] [Related]
13. High-efficiency B₄C/Mo₂C alternate multilayer grating for monochromators in the photon energy range from 0.7 to 3.4 keV.
Choueikani F; Lagarde B; Delmotte F; Krumrey M; Bridou F; Thomasset M; Meltchakov E; Polack F
Opt Lett; 2014 Apr; 39(7):2141-4. PubMed ID: 24686695
[TBL] [Abstract][Full Text] [Related]
14. Technology for radiation efficiency measurement of high-power halogen tungsten lamp used in calibration of high-energy laser energy meter.
Wei JF; Hu XY; Sun LQ; Zhang K; Chang Y
Appl Opt; 2015 Mar; 54(9):2289-95. PubMed ID: 25968513
[TBL] [Abstract][Full Text] [Related]
15. Consideration of signal to noise ratio for an imaging bolometer for ITER.
Peterson BJ; Reichle R; Pandya S; O'Mullane MG; Mukai K
Rev Sci Instrum; 2021 Apr; 92(4):043534. PubMed ID: 34243463
[TBL] [Abstract][Full Text] [Related]
16. Measurement of the mass energy-absorption coefficient of air for x-rays in the range from 3 to 60 keV.
Buhr H; Büermann L; Gerlach M; Krumrey M; Rabus H
Phys Med Biol; 2012 Dec; 57(24):8231-47. PubMed ID: 23192280
[TBL] [Abstract][Full Text] [Related]
17. A laboratory-based hard x-ray monochromator for high-resolution x-ray emission spectroscopy and x-ray absorption near edge structure measurements.
Seidler GT; Mortensen DR; Remesnik AJ; Pacold JI; Ball NA; Barry N; Styczinski M; Hoidn OR
Rev Sci Instrum; 2014 Nov; 85(11):113906. PubMed ID: 25430123
[TBL] [Abstract][Full Text] [Related]
18. Large-area avalanche photodiodes for the detection of soft x rays.
Gullikson EM; Gramsch E; Szawlowski M
Appl Opt; 1995 Aug; 34(22):4662-8. PubMed ID: 21052299
[TBL] [Abstract][Full Text] [Related]
19. High-Resolution High-Count-Rate X-ray Spectroscopy with State-of-the-Art Silicon Detectors.
Strüder L; Fiorini C; Gatti E; Hartmann R; Holl P; Krause N; Lechner P; Longoni A; Lutz G; Kemmer J; Meidinger N; Popp M; Soltau H; Weber U; Von Zanthier C
J Synchrotron Radiat; 1998 May; 5(Pt 3):268-74. PubMed ID: 15263490
[TBL] [Abstract][Full Text] [Related]
20. Metrology of pulsed radiation for 157-nm lithography.
Richter M; Kroth U; Gottwald A; Gerth C; Tiedtke K; Saito T; Tassy I; Vogler K
Appl Opt; 2002 Dec; 41(34):7167-72. PubMed ID: 12477104
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]