BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 24387828)

  • 1. Reconstruction of closed rupture of thumb flexor tendon pulleys with a single free palmaris longus tendon graft: a case report and review of literature.
    Fazilleau F; Cheval D; Richou J; Le Nen D
    Chir Main; 2014 Feb; 33(1):51-4. PubMed ID: 24387828
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Letter to editor related to "reconstruction of 4 closed rupture of thumb flexor tendon pulleys with a single free palmaris longus tendon graft: a case report and review of literature", by F. Fazilleau, D. Cheval, J. Richou and D. Le Nen. Chir Main 2014; 33: 51-4].
    Meyer Zu Reckendorf G; Allieu Y
    Chir Main; 2014 Sep; 33(4):233-4. PubMed ID: 25169200
    [No Abstract]   [Full Text] [Related]  

  • 3. Result of A1 pulley reconstruction after closed rupture of the thumb pulleys during childbirth.
    Kachouh N; Cerlier A; Bouyer M; Legré R
    Hand Surg Rehabil; 2018 Oct; 37(5):311-315. PubMed ID: 30026019
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Closed rupture of the thumb flexor tendon pulleys.
    Wilson SM; Roulot E; Le Viet D
    J Hand Surg Br; 2005 Dec; 30(6):621-3. PubMed ID: 16105714
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Closed flexor pulley rupture of the thumb: case report and review of literature.
    Kosiyatrakul A; Jitprapaikulsarn S; Durand S; Oberlin C
    Hand Surg; 2009; 14(2-3):139-42. PubMed ID: 20135743
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Gliding resistance of the flexor pollicis longus tendon after repair: does partial excision of the oblique pulley affect gliding resistance?
    Kutsumi K; Amadio PC; Zhao C; Zobitz ME; An KN
    Plast Reconstr Surg; 2006 Nov; 118(6):1423-1428. PubMed ID: 17051113
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Step Cut Lengthening: A Technique for Treatment of Flexor Pollicis Longus Tendon Rupture.
    Chong CW; Chen SH
    Ann Plast Surg; 2018 Apr; 80(4):353-355. PubMed ID: 29166314
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Secondary tendon reconstruction on the thumb].
    Bickert B; Kremer T; Kneser U
    Unfallchirurg; 2016 Dec; 119(12):986-992. PubMed ID: 27695881
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Flexor pulley reconstruction after rupture following corticosteroid injections for trigger thumb: a case report.
    Kimura M; Kuroshima N; Matsushita T
    Hand Surg; 2013; 18(3):425-8. PubMed ID: 24156592
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Flexor pollicis longus rupture in a trigger thumb: a case report.
    Taras JS; Iiams GJ; Gibbons M; Culp RW
    J Hand Surg Am; 1995 Mar; 20(2):276-7. PubMed ID: 7775768
    [No Abstract]   [Full Text] [Related]  

  • 11. Robust thumb flexor tendon repairs with a six-strand M-Tang method, pulley venting, and early active motion.
    Pan ZJ; Qin J; Zhou X; Chen J
    J Hand Surg Eur Vol; 2017 Nov; 42(9):909-914. PubMed ID: 28784034
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Flexor tendon pulley system: anatomy, pathology, treatment].
    Moutet F
    Chir Main; 2003 Feb; 22(1):1-12. PubMed ID: 12723303
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Traumatic flexor digitorum superficialis and A2-A3 pulley rupture: case report.
    Johnsen P; O'Shea K; Wolfe SW
    J Hand Surg Am; 2014 Mar; 39(3):524-6. PubMed ID: 24559629
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Closed traumatic rupture of the flexor pollicis longus tendon in zone T I: a case report.
    Uekubo K; Itoh S; Yoshioka T
    Hand Surg; 2015; 20(1):145-7. PubMed ID: 25609290
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Closed rupture of flexor tendon by hyperextension mechanism in wrist level (zone V): a report of three cases.
    Nho JH; Lee TK; Kim BS; Yoon HK; Gong HS; Suh YS
    Arch Orthop Trauma Surg; 2013 Jul; 133(7):1029-32. PubMed ID: 23604791
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Minimally invasive A2 flexor tendon pulley and biomechanical comparison with two accepted techniques.
    Mallo GC; Sless Y; Hurst LC; Serra-Hsu F
    Tech Hand Up Extrem Surg; 2008 Sep; 12(3):170-3. PubMed ID: 18776779
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Free tendon grafts in elder patients, a case report of repair of flexor pollicis longus tendon with a free palmaris longus graft in an 89-year-old woman.
    de Panafieu E; Upex P; Doursounian L; Robert N
    Ann Chir Plast Esthet; 2016 Feb; 61(1):76-9. PubMed ID: 25447212
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Extensor indicis-transfer compared with palmaris longus transplantation in reconstruction of extensor pollicis longus tendon: a retrospective study.
    Schaller P; Baer W; Carl HD
    Scand J Plast Reconstr Surg Hand Surg; 2007; 41(1):33-5. PubMed ID: 17484183
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Closed rupture of the flexor tendon pulleys of the thumb.
    Brown MS; O'Donnell J; Walz D
    Clin Imaging; 2019; 58():66-69. PubMed ID: 31252213
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Flexor pulley reconstruction.
    Dy CJ; Daluiski A
    Hand Clin; 2013 May; 29(2):235-42. PubMed ID: 23660059
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.