313 related articles for article (PubMed ID: 24398429)
1. Measuring skin temperature before, during and after exercise: a comparison of thermocouples and infrared thermography.
Fernandes Ade A; Amorim PR; Brito CJ; de Moura AG; Moreira DG; Costa CM; Sillero-Quintana M; Marins JC
Physiol Meas; 2014 Feb; 35(2):189-203. PubMed ID: 24398429
[TBL] [Abstract][Full Text] [Related]
2. Reproducibility of infrared thermography measurements in healthy individuals.
Zaproudina N; Varmavuo V; Airaksinen O; Närhi M
Physiol Meas; 2008 Apr; 29(4):515-24. PubMed ID: 18401069
[TBL] [Abstract][Full Text] [Related]
3. Comparison of infrared thermography and laser speckle contrast imaging for the dynamic assessment of digital microvascular function.
Pauling JD; Shipley JA; Raper S; Watson ML; Ward SG; Harris ND; McHugh NJ
Microvasc Res; 2012 Mar; 83(2):162-7. PubMed ID: 21763703
[TBL] [Abstract][Full Text] [Related]
4. Reliability and validity of skin temperature measurement by telemetry thermistors and a thermal camera during exercise in the heat.
James CA; Richardson AJ; Watt PW; Maxwell NS
J Therm Biol; 2014 Oct; 45():141-9. PubMed ID: 25436963
[TBL] [Abstract][Full Text] [Related]
5. Interexaminer reliability of infrared thermography for the diagnosis of complex regional pain syndrome.
Choi E; Lee PB; Nahm FS
Skin Res Technol; 2013 May; 19(2):189-93. PubMed ID: 23331254
[TBL] [Abstract][Full Text] [Related]
6. Thermographic imaging in sports and exercise medicine: A Delphi study and consensus statement on the measurement of human skin temperature.
Moreira DG; Costello JT; Brito CJ; Adamczyk JG; Ammer K; Bach AJE; Costa CMA; Eglin C; Fernandes AA; Fernández-Cuevas I; Ferreira JJA; Formenti D; Fournet D; Havenith G; Howell K; Jung A; Kenny GP; Kolosovas-Machuca ES; Maley MJ; Merla A; Pascoe DD; Priego Quesada JI; Schwartz RG; Seixas ARD; Selfe J; Vainer BG; Sillero-Quintana M
J Therm Biol; 2017 Oct; 69():155-162. PubMed ID: 29037377
[TBL] [Abstract][Full Text] [Related]
7. Are the infrared thermography findings skin temperature-dependent? a study on neck pain patients.
Zaproudina N; Airaksinen O; Närhi M
Skin Res Technol; 2013 Feb; 19(1):e537-44. PubMed ID: 23020845
[TBL] [Abstract][Full Text] [Related]
8. Infrared thermography for detailed registration of thermoregulation in premature infants.
Heimann K; Jergus K; Abbas AK; Heussen N; Leonhardt S; Orlikowsky T
J Perinat Med; 2013 Sep; 41(5):613-20. PubMed ID: 23443261
[TBL] [Abstract][Full Text] [Related]
9. Intra- and inter-session reliability and repeatability of an infrared thermography device designed for materials to measure skin temperature of the triceps surae muscle tissue of athletes.
Calvo-Lobo C; San-Antolín M; García-García D; Becerro-de-Bengoa-Vallejo R; Losa-Iglesias ME; Cosín-Matamoros J; Casado-Hernández I; Martínez-Jiménez EM; Mazoteras-Pardo V; Rodríguez-Sanz D
PeerJ; 2023; 11():e15011. PubMed ID: 36919164
[TBL] [Abstract][Full Text] [Related]
10. Monitoring changes in skin temperature associated with exercise in horses on a water treadmill by use of infrared thermography.
Yarnell K; Fleming J; Stratton TD; Brassington R
J Therm Biol; 2014 Oct; 45():110-6. PubMed ID: 25436959
[TBL] [Abstract][Full Text] [Related]
11. Validity of inner canthus temperature recorded by infrared thermography as a non-invasive surrogate measure for core temperature at rest, during exercise and recovery.
Fernandes AA; Moreira DG; Brito CJ; da Silva CD; Sillero-Quintana M; Pimenta EM; Bach AJ; Garcia ES; Bouzas Marins JC
J Therm Biol; 2016 Dec; 62(Pt A):50-55. PubMed ID: 27839549
[TBL] [Abstract][Full Text] [Related]
12. Infrared Thermography in Exercise Physiology: The Dawning of Exercise Radiomics.
Hillen B; Pfirrmann D; Nägele M; Simon P
Sports Med; 2020 Feb; 50(2):263-282. PubMed ID: 31734882
[TBL] [Abstract][Full Text] [Related]
13. The validity of wireless iButtons and thermistors for human skin temperature measurement.
Smith AD; Crabtree DR; Bilzon JL; Walsh NP
Physiol Meas; 2010 Jan; 31(1):95-114. PubMed ID: 19940348
[TBL] [Abstract][Full Text] [Related]
14. Infrared cameras overestimate skin temperature during rewarming from cold exposure.
Maley MJ; Hunt AP; Bach AJ; Eglin CM; Costello JT
J Therm Biol; 2020 Jul; 91():102614. PubMed ID: 32716864
[TBL] [Abstract][Full Text] [Related]
15. The application of infrared thermography in evaluation of patients at high risk for lower extremity peripheral arterial disease.
Huang CL; Wu YW; Hwang CL; Jong YS; Chao CL; Chen WJ; Wu YT; Yang WS
J Vasc Surg; 2011 Oct; 54(4):1074-80. PubMed ID: 21784604
[TBL] [Abstract][Full Text] [Related]
16. Infrared thermography in children: a reliable tool for differential diagnosis of peripheral microvascular dysfunction and Raynaud's phenomenon?
Martini G; Cappella M; Culpo R; Vittadello F; Sprocati M; Zulian F
Pediatr Rheumatol Online J; 2019 Oct; 17(1):68. PubMed ID: 31619252
[TBL] [Abstract][Full Text] [Related]
17. Does skin temperature difference as measured by infrared thermography within 6 months of acute herpes zoster infection correlate with pain level?
Han SS; Jung CH; Lee SC; Jung HJ; Kim YH
Skin Res Technol; 2010 May; 16(2):198-201. PubMed ID: 20456100
[TBL] [Abstract][Full Text] [Related]
18. FPA-based infrared thermography as applied to the study of cutaneous perspiration and stimulated vascular response in humans.
Vainer BG
Phys Med Biol; 2005 Dec; 50(23):R63-94. PubMed ID: 16306642
[TBL] [Abstract][Full Text] [Related]
19. Recent use of medical infrared thermography in skin neoplasms.
Magalhaes C; Vardasca R; Mendes J
Skin Res Technol; 2018 Nov; 24(4):587-591. PubMed ID: 29575378
[TBL] [Abstract][Full Text] [Related]
20. Comparison of infrared versus contact thermometry for measuring skin temperature during exercise in the heat.
Buono MJ; Jechort A; Marques R; Smith C; Welch J
Physiol Meas; 2007 Aug; 28(8):855-9. PubMed ID: 17664677
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]