These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
227 related articles for article (PubMed ID: 24405567)
1. An animal model to evaluate skin-implant-bone integration and gait with a prosthesis directly attached to the residual limb. Farrell BJ; Prilutsky BI; Kistenberg RS; Dalton JF; Pitkin M Clin Biomech (Bristol); 2014 Mar; 29(3):336-49. PubMed ID: 24405567 [TBL] [Abstract][Full Text] [Related]
2. Recent Progress in Animal Studies of the Skin- and Bone-integrated Pylon With Deep Porosity for Bone-Anchored Limb Prosthetics With and Without Neural Interface. Pitkin M; Cassidy C; Shevtsov MA; Jarrell JR; Park H; Farrell BJ; Dalton JF; Childers WL; Kistenberg RS; Oh K; Klishko AN; Prilutsky BI Mil Med; 2021 Jan; 186(Suppl 1):688-695. PubMed ID: 33499499 [TBL] [Abstract][Full Text] [Related]
3. Kinetics of individual limbs during level and slope walking with a unilateral transtibial bone-anchored prosthesis in the cat. Jarrell JR; Farrell BJ; Kistenberg RS; Dalton JF; Pitkin M; Prilutsky BI J Biomech; 2018 Jul; 76():74-83. PubMed ID: 29861094 [TBL] [Abstract][Full Text] [Related]
4. Skin and bone integrated prosthetic pylon: a pilot animal study. Pitkin M; Raykhtsaum G; Galibin OV; Protasov MV; Chihovskaya JV; Belyaeva IG J Rehabil Res Dev; 2006; 43(4):573-80. PubMed ID: 17123195 [TBL] [Abstract][Full Text] [Related]
5. Osseointegrated Prosthetic Implants for People With Lower-Limb Amputation: A Health Technology Assessment. Ontario Health (Quality) Ont Health Technol Assess Ser; 2019; 19(7):1-126. PubMed ID: 31911825 [TBL] [Abstract][Full Text] [Related]
6. A 24-month evaluation of a percutaneous osseointegrated limb-skin interface in an ovine amputation model. Jeyapalina S; Beck JP; Agarwal J; Bachus KN J Mater Sci Mater Med; 2017 Oct; 28(11):179. PubMed ID: 28980174 [TBL] [Abstract][Full Text] [Related]
7. Porous composite prosthetic pylon for integration with skin and bone. Pitkin M; Raykhtsaum G; Pilling J; Galibin OV; Protasov MV; Chihovskaya JV; Belyaeva IG; Blinova MI; Yudintseva NM; Potokin IL; Pinaev GP; Moxson V; Duz V J Rehabil Res Dev; 2007; 44(5):723-38. PubMed ID: 17943684 [TBL] [Abstract][Full Text] [Related]
8. Load response of an osseointegrated implant used in the treatment of unilateral transfemoral amputation: An early implant loosening case study. Robinson DL; Safai L; Harandi VJ; Graf M; Lizama LEC; Lee P; Galea MP; Khan F; Tse KM; Ackland DC Clin Biomech (Bristol); 2020 Mar; 73():201-212. PubMed ID: 32036173 [TBL] [Abstract][Full Text] [Related]
9. [Function of prosthesis components in lower limb amputees with bone-anchored percutaneous implants : Biomechanical aspects]. Blumentritt S Unfallchirurg; 2017 May; 120(5):385-394. PubMed ID: 28280845 [TBL] [Abstract][Full Text] [Related]
10. Two-stage implantation of the skin- and bone-integrated pylon seeded with autologous fibroblasts induced into osteoblast differentiation for direct skeletal attachment of limb prostheses. Shevtsov MA; Galibin OV; Yudintceva NM; Blinova MI; Pinaev GP; Ivanova AA; Savchenko ON; Suslov DN; Potokin IL; Pitkin E; Raykhtsaum G; Pitkin MR J Biomed Mater Res A; 2014 Sep; 102(9):3033-48. PubMed ID: 24115308 [TBL] [Abstract][Full Text] [Related]
12. Histologic and morphologic evaluation of explanted bone anchors from bone-anchored hearing aids. Mlynski R; Goldberg E; Ebmeyer J; Scheich M; Gattenlöhner S; Schwager K; Hagen R; Shehata-Dieler W Eur Arch Otorhinolaryngol; 2009 May; 266(5):745-52. PubMed ID: 18853170 [TBL] [Abstract][Full Text] [Related]
13. Implant survival, adverse events, and bone remodeling of osseointegrated percutaneous implants for transhumeral amputees. Tsikandylakis G; Berlin Ö; Brånemark R Clin Orthop Relat Res; 2014 Oct; 472(10):2947-56. PubMed ID: 24879569 [TBL] [Abstract][Full Text] [Related]
14. Biomechanical characteristics of transfemoral bone-anchored prostheses during gait: A review of literature. Ravari R; Rehani M; Hebert JS Prosthet Orthot Int; 2024 Aug; 48(4):412-421. PubMed ID: 37639566 [TBL] [Abstract][Full Text] [Related]
15. Application of the skin and bone integrated pylon with titanium oxide nanotubes and seeded with dermal fibroblasts. Shevtsov MA; Yudintceva N; Blinova M; Pinaev G; Galibin O; Potokin I; Popat KC; Pitkin M Prosthet Orthot Int; 2015 Dec; 39(6):477-86. PubMed ID: 25249382 [TBL] [Abstract][Full Text] [Related]
16. Osteomyelitis Risk in Patients With Transfemoral Amputations Treated With Osseointegration Prostheses. Tillander J; Hagberg K; Berlin Ö; Hagberg L; Brånemark R Clin Orthop Relat Res; 2017 Dec; 475(12):3100-3108. PubMed ID: 28940152 [TBL] [Abstract][Full Text] [Related]
17. The effect of cortical thickness and thread profile dimensions on stress and strain in bone-anchored implants for amputation prostheses. Thesleff A; Ortiz-Catalan M; Brånemark R J Mech Behav Biomed Mater; 2022 May; 129():105148. PubMed ID: 35248873 [TBL] [Abstract][Full Text] [Related]
18. Implant-delivered Alendronate Causes a Dose-dependent Response on Net Bone Formation Around Porous Titanium Implants in Canines. Pura JA; Bobyn JD; Tanzer M Clin Orthop Relat Res; 2016 May; 474(5):1224-33. PubMed ID: 26831478 [TBL] [Abstract][Full Text] [Related]