BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

190 related articles for article (PubMed ID: 24417624)

  • 1. Interference-free proteome quantification with MS/MS-based isobaric isotopologue detection.
    Bamberger C; Pankow S; Park SK; Yates JR
    J Proteome Res; 2014 Mar; 13(3):1494-501. PubMed ID: 24417624
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Investigating Acquisition Performance on the Orbitrap Fusion When Using Tandem MS/MS/MS Scanning with Isobaric Tags.
    Hughes CS; Spicer V; Krokhin OV; Morin GB
    J Proteome Res; 2017 May; 16(5):1839-1846. PubMed ID: 28418257
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Trends in the Design of New Isobaric Labeling Reagents for Quantitative Proteomics.
    Bąchor R; Waliczek M; Stefanowicz P; Szewczuk Z
    Molecules; 2019 Feb; 24(4):. PubMed ID: 30781343
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A Collision-Induced Dissociation Cleavable Isobaric Tag for Peptide Fragment Ion-Based Quantification in Proteomics.
    Tian X; de Vries MP; Permentier HP; Bischoff R
    J Proteome Res; 2020 Sep; 19(9):3817-3824. PubMed ID: 32786690
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative accuracy in mass spectrometry based proteomics of complex samples: the impact of labeling and precursor interference.
    Sandberg A; Branca RM; Lehtiö J; Forshed J
    J Proteomics; 2014 Jan; 96():133-44. PubMed ID: 24211767
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Partially isobaric peptide termini labeling assisted proteome quantitation based on MS and MS/MS signals.
    Zhang S; Wu Q; Shan Y; Zhou Y; Zhang L; Zhang Y
    J Proteomics; 2015 Jan; 114():152-60. PubMed ID: 25434490
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of a Dual Isolation Width Acquisition Method for Isobaric Labeling Ratio Decompression.
    Roumeliotis TI; Weisser H; Choudhary JS
    J Proteome Res; 2019 Mar; 18(3):1433-1440. PubMed ID: 30576155
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of data analysis parameters and MS/MS fragmentation techniques for quantitative proteome analysis using isobaric peptide termini labeling (IPTL).
    Koehler CJ; Arntzen MØ; Treumann A; Thiede B
    Anal Bioanal Chem; 2012 Sep; 404(4):1103-14. PubMed ID: 22460078
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A novel triplex isobaric termini labeling quantitative approach for simultaneously supplying three quantitative sources.
    Jiang H; Yin H; Xie L; Zhang Y; Zhang L; Yang PY; Lu H
    Anal Chim Acta; 2018 Feb; 1001():70-77. PubMed ID: 29291808
    [TBL] [Abstract][Full Text] [Related]  

  • 10. iTRAQ labeling is superior to mTRAQ for quantitative global proteomics and phosphoproteomics.
    Mertins P; Udeshi ND; Clauser KR; Mani DR; Patel J; Ong SE; Jaffe JD; Carr SA
    Mol Cell Proteomics; 2012 Jun; 11(6):M111.014423. PubMed ID: 22210691
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantitative proteome analysis using isobaric peptide termini labeling (IPTL).
    Arntzen MO; Koehler CJ; Treumann A; Thiede B
    Methods Mol Biol; 2011; 753():65-76. PubMed ID: 21604116
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development of novel isobaric tags enables accurate and sensitive multiplexed proteomics using complementary ions.
    Li M; Ma M; Li L
    Anal Bioanal Chem; 2023 Nov; 415(28):6951-6960. PubMed ID: 37530794
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Benchmarking stable isotope labeling based quantitative proteomics.
    Altelaar AF; Frese CK; Preisinger C; Hennrich ML; Schram AW; Timmers HT; Heck AJ; Mohammed S
    J Proteomics; 2013 Aug; 88():14-26. PubMed ID: 23085607
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Relative protein quantification by MS/MS using the tandem mass tag technology.
    Dayon L; Sanchez JC
    Methods Mol Biol; 2012; 893():115-27. PubMed ID: 22665298
    [TBL] [Abstract][Full Text] [Related]  

  • 15. iTRAQ-Based Shotgun Proteomics Approach for Relative Protein Quantification.
    Núñez EV; Domont GB; Nogueira FCS
    Methods Mol Biol; 2017; 1546():267-274. PubMed ID: 27896776
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improved precision of iTRAQ and TMT quantification by an axial extraction field in an Orbitrap HCD cell.
    Pichler P; Köcher T; Holzmann J; Möhring T; Ammerer G; Mechtler K
    Anal Chem; 2011 Feb; 83(4):1469-74. PubMed ID: 21275378
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mass defect-based pseudo-isobaric dimethyl labeling for proteome quantification.
    Zhou Y; Shan Y; Wu Q; Zhang S; Zhang L; Zhang Y
    Anal Chem; 2013 Nov; 85(22):10658-63. PubMed ID: 24180428
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Isobaric labeling-based relative quantification in shotgun proteomics.
    Rauniyar N; Yates JR
    J Proteome Res; 2014 Dec; 13(12):5293-309. PubMed ID: 25337643
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Systematic comparison of label-free, metabolic labeling, and isobaric chemical labeling for quantitative proteomics on LTQ Orbitrap Velos.
    Li Z; Adams RM; Chourey K; Hurst GB; Hettich RL; Pan C
    J Proteome Res; 2012 Mar; 11(3):1582-90. PubMed ID: 22188275
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Lysine Propionylation To Boost Sequence Coverage and Enable a "Silent SILAC" Strategy for Relative Protein Quantification.
    Schräder CU; Moore S; Goodarzi AA; Schriemer DC
    Anal Chem; 2018 Aug; 90(15):9077-9084. PubMed ID: 29975514
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.