153 related articles for article (PubMed ID: 24418435)
1. Effect of thermomechanical pre-treatment on short- and long-term Ni release from biomedical NiTi.
Freiberg KE; Bremer-Streck S; Kiehntopf M; Rettenmayr M; Undisz A
Acta Biomater; 2014 May; 10(5):2290-5. PubMed ID: 24418435
[TBL] [Abstract][Full Text] [Related]
2. In situ observation of surface oxide layers on medical grade Ni-Ti alloy during straining.
Undisz A; Schrempel F; Wesch W; Rettenmayr M
J Biomed Mater Res A; 2009 Mar; 88(4):1000-9. PubMed ID: 18384174
[TBL] [Abstract][Full Text] [Related]
3. Microstructure, nickel suppression and mechanical characteristics of electropolished and photoelectrocatalytically oxidized biomedical nickel titanium shape memory alloy.
Chu CL; Guo C; Sheng XB; Dong YS; Lin PH; Yeung KW; Chu PK
Acta Biomater; 2009 Jul; 5(6):2238-45. PubMed ID: 19251496
[TBL] [Abstract][Full Text] [Related]
4. Surface structure and properties of biomedical NiTi shape memory alloy after Fenton's oxidation.
Chu CL; Hu T; Wu SL; Dong YS; Yin LH; Pu YP; Lin PH; Chung CY; Yeung KW; Chu PK
Acta Biomater; 2007 Sep; 3(5):795-806. PubMed ID: 17466609
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of passive oxide layer formation-biocompatibility relationship in NiTi shape memory alloys: geometry and body location dependency.
Toker SM; Canadinc D; Maier HJ; Birer O
Mater Sci Eng C Mater Biol Appl; 2014 Mar; 36():118-29. PubMed ID: 24433894
[TBL] [Abstract][Full Text] [Related]
6. The influence of surface oxides on the distribution and release of nickel from Nitinol wires.
Shabalovskaya SA; Tian H; Anderegg JW; Schryvers DU; Carroll WU; Van Humbeeck J
Biomaterials; 2009 Feb; 30(4):468-77. PubMed ID: 18996586
[TBL] [Abstract][Full Text] [Related]
7. Structure and thermomechanical behavior of NiTiPt shape memory alloy wires.
Lin B; Gall K; Maier HJ; Waldron R
Acta Biomater; 2009 Jan; 5(1):257-67. PubMed ID: 18718825
[TBL] [Abstract][Full Text] [Related]
8. Mechanism of oxide layer growth during annealing of NiTi.
Undisz A; Schrempel F; Wesch W; Rettenmayr M
J Biomed Mater Res A; 2012 Jul; 100(7):1743-50. PubMed ID: 22467267
[TBL] [Abstract][Full Text] [Related]
9. Stability of Ni in nitinol oxide surfaces.
Tian H; Schryvers D; Liu D; Jiang Q; Van Humbeeck J
Acta Biomater; 2011 Feb; 7(2):892-9. PubMed ID: 20849983
[TBL] [Abstract][Full Text] [Related]
10. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
[TBL] [Abstract][Full Text] [Related]
11. New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility.
Michiardi A; Aparicio C; Planell JA; Gil FJ
J Biomed Mater Res B Appl Biomater; 2006 May; 77(2):249-56. PubMed ID: 16245290
[TBL] [Abstract][Full Text] [Related]
12. Tensile deformation of NiTi wires.
Gall K; Tyber J; Brice V; Frick CP; Maier HJ; Morgan N
J Biomed Mater Res A; 2005 Dec; 75(4):810-23. PubMed ID: 16138359
[TBL] [Abstract][Full Text] [Related]
13. Length-dependent corrosion behavior, Ni
Hang R; Liu Y; Bai L; Zhang X; Huang X; Jia H; Tang B
Mater Sci Eng C Mater Biol Appl; 2018 Aug; 89():1-7. PubMed ID: 29752078
[TBL] [Abstract][Full Text] [Related]
14. Density functional theory simulation of titanium migration and reaction with oxygen in the early stages of oxidation of equiatomic NiTi alloy.
Nolan M; Tofail SA
Biomaterials; 2010 May; 31(13):3439-48. PubMed ID: 20144474
[TBL] [Abstract][Full Text] [Related]
15. Effect of surface treatment on the bioactivity of nickel-titanium.
Chrzanowski W; Neel EA; Armitage DA; Knowles JC
Acta Biomater; 2008 Nov; 4(6):1969-84. PubMed ID: 18565807
[TBL] [Abstract][Full Text] [Related]
16. Microstructural studies of 35 degrees C copper Ni-Ti orthodontic wire and TEM confirmation of low-temperature martensite transformation.
Brantley WA; Guo W; Clark WA; Iijima M
Dent Mater; 2008 Feb; 24(2):204-10. PubMed ID: 17561249
[TBL] [Abstract][Full Text] [Related]
17. Behaviour of human endothelial cells on surface modified NiTi alloy.
Plant SD; Grant DM; Leach L
Biomaterials; 2005 Sep; 26(26):5359-67. PubMed ID: 15814134
[TBL] [Abstract][Full Text] [Related]
18. Effect of fluoride prophylactic agents on the mechanical properties of nickel-titanium-based orthodontic wires.
Walker MP; White RJ; Kula KS
Am J Orthod Dentofacial Orthop; 2005 Jun; 127(6):662-9. PubMed ID: 15953890
[TBL] [Abstract][Full Text] [Related]
19. The atomic level structure of the TiO(2)-NiTi interface.
Nolan M; Tofail SA
Phys Chem Chem Phys; 2010 Sep; 12(33):9742-50. PubMed ID: 20552125
[TBL] [Abstract][Full Text] [Related]
20. Corrosion susceptibility and nickel release of nickel titanium wires during clinical application.
Petoumeno E; Kislyuk M; Hoederath H; Keilig L; Bourauel C; Jäger A
J Orofac Orthop; 2008 Nov; 69(6):411-23. PubMed ID: 19169638
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]