BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 24418737)

  • 1. Myocardial infarction after left ventricular assist device implantation: clinical course, role of aortic root thrombus, and outcomes.
    Fried J; Han J; Naka Y; Jorde UP; Uriel N
    J Heart Lung Transplant; 2014 Jan; 33(1):112-5. PubMed ID: 24418737
    [No Abstract]   [Full Text] [Related]  

  • 2. Aortic valve opening and thrombotic events with continuous-flow left ventricular assist devices.
    Saeed O; Maybaum S; Alessandro DD; Goldstein DJ; Patel SR
    J Heart Lung Transplant; 2014 Jan; 33(1):109-12. PubMed ID: 23937883
    [No Abstract]   [Full Text] [Related]  

  • 3. Continuous flow left ventricular assist device related aortic root thrombosis complicated by left main coronary artery occlusion.
    Shah S; Mehra MR; Couper GS; Desai AS
    J Heart Lung Transplant; 2014 Jan; 33(1):119-20. PubMed ID: 24418738
    [No Abstract]   [Full Text] [Related]  

  • 4. Carotid-bulb thrombus and continuous-flow left ventricular assist devices: a novel observation.
    Reul JT; Reul GJ; Frazier OH
    J Heart Lung Transplant; 2014 Jan; 33(1):107-9. PubMed ID: 24290833
    [No Abstract]   [Full Text] [Related]  

  • 5. Durability of central aortic valve closure in patients with continuous flow left ventricular assist devices.
    McKellar SH; Deo S; Daly RC; Durham LA; Joyce LD; Stulak JM; Park SJ
    J Thorac Cardiovasc Surg; 2014 Jan; 147(1):344-8. PubMed ID: 23246052
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Natural history and clinical effect of aortic valve regurgitation after left ventricular assist device implantation.
    Rajagopal K; Daneshmand MA; Patel CB; Ganapathi AM; Schechter MA; Rogers JG; Milano CA
    J Thorac Cardiovasc Surg; 2013 May; 145(5):1373-9. PubMed ID: 23312101
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Case 7-2013: Percutaneous closure of the aortic valve for severe aortic insufficiency due to a left ventricular assist device.
    Feider AJ; Chaney MA; Cowger JA; Thomas SS; Jorde UP
    J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1407-13. PubMed ID: 23994175
    [No Abstract]   [Full Text] [Related]  

  • 8. Aortic regurgitation during left ventricular assist device support.
    Haghi D; Suselbeck T; Saur J
    J Heart Lung Transplant; 2007 Nov; 26(11):1220-1. PubMed ID: 18022095
    [No Abstract]   [Full Text] [Related]  

  • 9. Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices.
    Pak SW; Uriel N; Takayama H; Cappleman S; Song R; Colombo PC; Charles S; Mancini D; Gillam L; Naka Y; Jorde UP
    J Heart Lung Transplant; 2010 Oct; 29(10):1172-6. PubMed ID: 20619680
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Insufficiency of the native aortic valve and left ventricular assist system inflow valve after support with an implantable left ventricular assist system: signs, symptoms, and concerns.
    Samuels LE; Thomas MP; Holmes EC; Narula J; Fitzpatrick J; Wood D; Fyfe B; Wechsler AS
    J Thorac Cardiovasc Surg; 2001 Aug; 122(2):380-1. PubMed ID: 11479514
    [No Abstract]   [Full Text] [Related]  

  • 11. Numerical characterization of hemodynamics conditions near aortic valve after implantation of Left Ventricular Assist Device.
    Quaini A; Canić S; Paniagua D
    Math Biosci Eng; 2011 Jul; 8(3):785-806. PubMed ID: 21675811
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Right ventricular failure after left ventricular assist device implantation with concomitant pulmonary embolectomy needing right ventricular assist device support in a patient with terminal heart failure and asymptomatic pulmonary thrombus.
    Stepanenko A; Potapov EV; Krabatsch T; Hetzer R
    Interact Cardiovasc Thorac Surg; 2010 Jan; 10(1):154-5. PubMed ID: 19833639
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Aortic root and valve thrombosis after implantation of a left ventricular assist device.
    Freed BH; Jeevanandam V; Jolly N
    J Invasive Cardiol; 2011 Apr; 23(4):E63-5. PubMed ID: 21474853
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Aortic valve thrombosis after implantation of temporary left ventricular assist device.
    Crestanello JA; Orsinelli DA; Firstenberg MS; Sai-Sudhakar C
    Interact Cardiovasc Thorac Surg; 2009 Jun; 8(6):661-2. PubMed ID: 19299423
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of aortic insufficiency in patients supported with continuous flow left ventricular assist devices.
    Soleimani B; Haouzi A; Manoskey A; Stephenson ER; El-Banayosy A; Pae WE
    ASAIO J; 2012; 58(4):326-9. PubMed ID: 22569164
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Proximal thoracic aorta dimensions after continuous-flow left ventricular assist device implantation: Longitudinal changes and relation to aortic valve insufficiency.
    Fine NM; Park SJ; Stulak JM; Topilsky Y; Daly RC; Joyce LD; Pereira NL; Schirger JA; Edwards BS; Lin G; Kushwaha SS
    J Heart Lung Transplant; 2016 Apr; 35(4):423-32. PubMed ID: 26632029
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Percutaneous closure of an incompetent aortic valve using an occluder device in a patient with left ventricular assist device.
    Feider A; Dhawan R; Chaney M
    Anesth Analg; 2013 Nov; 117(5):1078-80. PubMed ID: 24029857
    [No Abstract]   [Full Text] [Related]  

  • 18. Novel application of Angiojet rheolytic thrombectomy for massive thrombosis of the native aortic valve and Jarvick 2000 ventricular assist device in a patient with end-stage heart failure.
    Barbieri A; Bertelli L; Sangiorgi GM
    Catheter Cardiovasc Interv; 2011 Nov; 78(6):958-61. PubMed ID: 21805566
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes.
    Kormos RL; Teuteberg JJ; Pagani FD; Russell SD; John R; Miller LW; Massey T; Milano CA; Moazami N; Sundareswaran KS; Farrar DJ;
    J Thorac Cardiovasc Surg; 2010 May; 139(5):1316-24. PubMed ID: 20132950
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Surgical correction of aortic valve insufficiency after left ventricular assist device implantation.
    Atkins BZ; Hashmi ZA; Ganapathi AM; Harrison JK; Hughes GC; Rogers JG; Milano CA
    J Thorac Cardiovasc Surg; 2013 Nov; 146(5):1247-52. PubMed ID: 23870154
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.