BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

283 related articles for article (PubMed ID: 24421262)

  • 1. Lack of heritability of exhaled volatile compound pattern: an electronic nose twin study.
    Tarnoki DL; Bikov A; Tarnoki AD; Lazar Z; Szilagyi BK; Korosi BZ; Horvath T; Littvay L; Losonczy G; Horvath I
    J Breath Res; 2014 Mar; 8(1):016001. PubMed ID: 24421262
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Breathing Rhythm Variations during Wash-In Do Not Influence Exhaled Volatile Organic Compound Profile Analyzed by an Electronic Nose.
    Dragonieri S; Quaranta VN; Carratù P; Ranieri T; Buonamico E; Carpagnano GE
    Molecules; 2021 May; 26(9):. PubMed ID: 34064506
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The ovarian cycle may influence the exhaled volatile organic compound profile analyzed by an electronic nose.
    Dragonieri S; Quaranta VN; Carratu P; Ranieri T; Resta O
    J Breath Res; 2018 Mar; 12(2):021002. PubMed ID: 29199639
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evening and morning exhaled volatile compound patterns are different in obstructive sleep apnoea assessed with electronic nose.
    Kunos L; Bikov A; Lazar Z; Korosi BZ; Benedek P; Losonczy G; Horvath I
    Sleep Breath; 2015 Mar; 19(1):247-53. PubMed ID: 24840212
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of circadian rhythm on exhaled breath profiling by electronic nose.
    Liotino V; Dragonieri S; Quaranta VN; Carratu P; Ranieri T; Resta O
    J Biol Regul Homeost Agents; 2018; 32(5):1261-1265. PubMed ID: 30334423
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Expiratory flow rate, breath hold and anatomic dead space influence electronic nose ability to detect lung cancer.
    Bikov A; Hernadi M; Korosi BZ; Kunos L; Zsamboki G; Sutto Z; Tarnoki AD; Tarnoki DL; Losonczy G; Horvath I
    BMC Pulm Med; 2014 Dec; 14():202. PubMed ID: 25510554
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Exhaled volatile organic compounds analysis by e-nose can detect idiopathic pulmonary fibrosis.
    Dragonieri S; Scioscia G; Quaranta VN; Carratu P; Venuti MP; Falcone M; Carpagnano GE; Foschino Barbaro MP; Resta O; Lacedonia D
    J Breath Res; 2020 Jul; 14(4):047101. PubMed ID: 32320958
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of age and gender on the profile of exhaled volatile organic compounds analyzed by an electronic nose.
    Dragonieri S; Quaranta VN; Carratu P; Ranieri T; Resta O
    J Bras Pneumol; 2016 Apr; 42(2):143-5. PubMed ID: 27167436
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Short-Term Effect of Cigarette Smoke on Exhaled Volatile Organic Compounds Profile Analyzed by an Electronic Nose.
    Dragonieri S; Quaranta VN; Buonamico E; Battisti C; Ranieri T; Carratu P; Carpagnano GE
    Biosensors (Basel); 2022 Jul; 12(7):. PubMed ID: 35884323
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Genetic and environmental contributions to abdominal aortic aneurysm development in a twin population.
    Wahlgren CM; Larsson E; Magnusson PK; Hultgren R; Swedenborg J
    J Vasc Surg; 2010 Jan; 51(1):3-7; discussion 7. PubMed ID: 19939604
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD.
    Dragonieri S; Annema JT; Schot R; van der Schee MP; Spanevello A; Carratú P; Resta O; Rabe KF; Sterk PJ
    Lung Cancer; 2009 May; 64(2):166-70. PubMed ID: 18834643
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sex and Smoking Status Effects on the Early Detection of Early Lung Cancer in High-Risk Smokers Using an Electronic Nose.
    McWilliams A; Beigi P; Srinidhi A; Lam S; MacAulay CE
    IEEE Trans Biomed Eng; 2015 Aug; 62(8):2044-54. PubMed ID: 25775482
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Identification of profiles of volatile organic compounds in exhaled breath by means of an electronic nose as a proposal for a screening method for breast cancer: a case-control study.
    Díaz de León-Martínez L; Rodríguez-Aguilar M; Gorocica-Rosete P; Domínguez-Reyes CA; Martínez-Bustos V; Tenorio-Torres JA; Ornelas-Rebolledo O; Cruz-Ramos JA; Balderas-Segura B; Flores-Ramírez R
    J Breath Res; 2020 Sep; 14(4):046009. PubMed ID: 32698165
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Exhaled breath profiling in patients with COPD and OSA overlap syndrome: a pilot study.
    Dragonieri S; Quaranta VN; Carratu P; Ranieri T; Resta O
    J Breath Res; 2016 Nov; 10(4):041001. PubMed ID: 27811380
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Exhaled breath profiling by electronic nose enabled discrimination of allergic rhinitis and extrinsic asthma.
    Dragonieri S; Quaranta VN; Carratu P; Ranieri T; Resta O
    Biomarkers; 2019 Feb; 24(1):70-75. PubMed ID: 30074408
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Exhaled breath profiling enables discrimination of chronic obstructive pulmonary disease and asthma.
    Fens N; Zwinderman AH; van der Schee MP; de Nijs SB; Dijkers E; Roldaan AC; Cheung D; Bel EH; Sterk PJ
    Am J Respir Crit Care Med; 2009 Dec; 180(11):1076-82. PubMed ID: 19713445
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultrafast gas chromatography coupled to electronic nose to identify volatile biomarkers in exhaled breath from chronic obstructive pulmonary disease patients: A pilot study.
    Rodríguez-Aguilar M; Ramírez-García S; Ilizaliturri-Hernández C; Gómez-Gómez A; Van-Brussel E; Díaz-Barriga F; Medellín-Garibay S; Flores-Ramírez R
    Biomed Chromatogr; 2019 Dec; 33(12):e4684. PubMed ID: 31423612
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Exhaled-breath Testing for Prostate Cancer Based on Volatile Organic Compound Profiling Using an Electronic Nose Device (Aeonose™): A Preliminary Report.
    Waltman CG; Marcelissen TAT; van Roermund JGH
    Eur Urol Focus; 2020 Nov; 6(6):1220-1225. PubMed ID: 30482583
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An electronic nose in the discrimination of obese patients with and without obstructive sleep apnoea.
    Dragonieri S; Porcelli F; Longobardi F; Carratù P; Aliani M; Ventura VA; Tutino M; Quaranta VN; Resta O; de Gennaro G
    J Breath Res; 2015 Apr; 9(2):026005. PubMed ID: 25891965
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Integration of electronic nose technology with spirometry: validation of a new approach for exhaled breath analysis.
    de Vries R; Brinkman P; van der Schee MP; Fens N; Dijkers E; Bootsma SK; de Jongh FH; Sterk PJ
    J Breath Res; 2015 Oct; 9(4):046001. PubMed ID: 26469298
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.