BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 24421961)

  • 1. The influence of tube potential on periodontal bone level measurements and subjective image quality using a digital photostimulable storage phosphor sensor.
    Vandenberghe B; Jacobs R
    J Oral Maxillofac Res; 2010; 1(1):e5. PubMed ID: 24421961
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 1: the influence of X-ray generator on periodontal measurements using conventional and digital receptors.
    Vandenberghe B; Corpas L; Bosmans H; Yang J; Jacobs R
    Clin Oral Investig; 2011 Aug; 15(4):537-49. PubMed ID: 20443035
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 2: the influence of intra-oral image receptor on periodontal measurements.
    Vandenberghe B; Bosmans H; Yang J; Jacobs R
    Clin Oral Investig; 2011 Aug; 15(4):551-62. PubMed ID: 20461423
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Investigation of beam quality for digital chest radiography with RbBr:Tl(+) photostimulable storage phosphors].
    Kawata H
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2003 Sep; 59(9):1174-82. PubMed ID: 14593331
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Digital method for quantification of circumferential periodontal bone level using cone beam CT.
    Fleiner J; Hannig C; Schulze D; Stricker A; Jacobs R
    Clin Oral Investig; 2013 Mar; 17(2):389-96. PubMed ID: 22431146
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Detection of periodontal bone loss using digital intraoral and cone beam computed tomography images: an in vitro assessment of bony and/or infrabony defects.
    Vandenberghe B; Jacobs R; Yang J
    Dentomaxillofac Radiol; 2008 Jul; 37(5):252-60. PubMed ID: 18606746
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Diagnostic validity (or acuity) of 2D CCD versus 3D CBCT-images for assessing periodontal breakdown.
    Vandenberghe B; Jacobs R; Yang J
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2007 Sep; 104(3):395-401. PubMed ID: 17613257
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The use of high-resolution digital imaging technology for small diameter K-file length determination in endodontics.
    Vandenberghe B; Bud M; Sutanto A; Jacobs R
    Clin Oral Investig; 2010 Apr; 14(2):223-31. PubMed ID: 19452176
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of tube potential setting and dose on the visibility of lesions in intraoral radiography.
    Kaeppler G; Dietz K; Reinert S
    Dentomaxillofac Radiol; 2007 Feb; 36(2):75-9. PubMed ID: 17403883
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Endodontic measurements in digital radiographs acquired by a photostimulable, storage phosphor system.
    Borg E; Gröndahl HG
    Endod Dent Traumatol; 1996 Feb; 12(1):20-4. PubMed ID: 8631285
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Effects on Absorbed Dose Distribution in Intraoral X-ray Imaging When Using Tube Voltages of 60 and 70 kV for Bitewing Imaging.
    Hellén-Halme K; Nilsson M
    J Oral Maxillofac Res; 2013; 4(3):e2. PubMed ID: 24422035
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Some characteristics of solid-state and photo-stimulable phosphor detectors for intra-oral radiography.
    Borg E
    Swed Dent J Suppl; 1999; 139():i-viii, 1-67. PubMed ID: 10635104
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of intraoral digital radiography and cone-beam computed tomography in the measurement of periodontal bone defects.
    Abdinian M; Yaghini J; Jazi L
    Dent Med Probl; 2020; 57(3):269-273. PubMed ID: 33074598
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of intraoral radiography and cone-beam computed tomography for the detection of periodontal defects: an in vitro study.
    Bagis N; Kolsuz ME; Kursun S; Orhan K
    BMC Oral Health; 2015 May; 15():64. PubMed ID: 26016804
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of beam quality and readout direction in the edge profile on the modulation transfer function of photostimulable phosphor systems via the edge method.
    Takarabe S; Kuramoto T; Shibayama Y; Tsuru H; Tatsumi M; Kato T; Okamura K; Yoshiura K
    J Med Imaging (Bellingham); 2021 Jul; 8(4):043501. PubMed ID: 34307736
    [No Abstract]   [Full Text] [Related]  

  • 16. Marginal bone level buccal to mandibular molars in digital radiographs from charge-coupled device and storage phosphor systems. An in vitro study.
    Borg E; Gröndahl K; Gröndahl HG
    J Clin Periodontol; 1997 May; 24(5):306-12. PubMed ID: 9178109
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of exposure parameters on detecting clear and unclear mandibular canals using two digital intra-oral sensors - An experimental study.
    Jasa-Andrade GR; Castillo AA; Arriola-Guillén LE
    Indian J Dent Res; 2021; 32(4):480-484. PubMed ID: 35645075
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Periodontal disease morbidity quantification. II. Validation of alveolar bone loss measurements and vertical defect diagnosis from digital bite-wing images.
    Hildebolt CF; Vannier MW; Shrout MK; Pilgram TK; Province M; Vahey EP; Rietz DW
    J Periodontol; 1990 Oct; 61(10):623-32. PubMed ID: 2231229
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Automatic exposure compensation of digital radiographic technologies does not affect alveolar bone-level measurement.
    Gaêta-Araujo H; Oliveira-Santos N; de Oliveira Reis L; Nascimento EHL; Oliveira-Santos C
    Oral Radiol; 2023 Jan; 39(1):53-58. PubMed ID: 35218461
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Subjective image quality of solid-state and photostimulable phosphor systems for digital intra-oral radiography.
    Borg E; Attaelmanan A; Gröndahl HG
    Dentomaxillofac Radiol; 2000 Mar; 29(2):70-5. PubMed ID: 10808218
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.