219 related articles for article (PubMed ID: 244328)
21. Comparison of three transmittance oximeters.
Strohl KP; House PM; Holic JF; Fouke JM; Cheung PW
Med Instrum; 1986; 20(3):143-9. PubMed ID: 3724588
[TBL] [Abstract][Full Text] [Related]
22. Buccal pulse oximeter is more accurate than finger pulse oximeter in measuring oxygen saturation.
O'Leary RJ; Landon M; Benumof JL
Anesth Analg; 1992 Oct; 75(4):495-8. PubMed ID: 1530160
[TBL] [Abstract][Full Text] [Related]
23. Comparison of three methods for determining oxygen saturation in arterial blood.
Thomas VE; Anema RJ; McNamara JJ
Am J Med Technol; 1975 Oct; 41(10):360-3. PubMed ID: 1190261
[TBL] [Abstract][Full Text] [Related]
24. Design and evaluation of a new reflectance pulse oximeter sensor.
Mendelson Y; Kent JC; Yocum BL; Birle MJ
Med Instrum; 1988 Aug; 22(4):167-73. PubMed ID: 3173170
[TBL] [Abstract][Full Text] [Related]
25. Pulse oximetry--principle and first experiences during anesthesia.
Dorlas JC; Kuipers AH
Acta Anaesthesiol Belg; 1987; 38(2):133-8. PubMed ID: 3661105
[TBL] [Abstract][Full Text] [Related]
26. [Pulse oximetry as a continuous, noninvasive monitoring procedure. Comparison of 2 instruments].
Altemeyer KH; Mayer J; Berg-Seiter S; Fösel T
Anaesthesist; 1986 Jan; 35(1):43-5. PubMed ID: 3963352
[TBL] [Abstract][Full Text] [Related]
27. A comparison of a new reflectance oximeter with the Hewlett-Packard ear oximeter.
Decker MJ; Dickensheets D; Arnold JL; Cheung PW; Strohl KP
Biomed Instrum Technol; 1990; 24(2):122-6. PubMed ID: 2322755
[TBL] [Abstract][Full Text] [Related]
28. [Comparison of the course of oxygen saturation and transcutaneous oxygen pressure in nonspecific inhalative provocation].
Hoffarth HP; Reier W; Ulmer WT
Pneumologie; 1990 Feb; 44 Suppl 1():364-5. PubMed ID: 2195519
[TBL] [Abstract][Full Text] [Related]
29. Evaluation of Biox IIA ear oximeter.
Tweeddale PM; Douglas NJ
Thorax; 1985 Nov; 40(11):825-7. PubMed ID: 4071459
[TBL] [Abstract][Full Text] [Related]
30. [Non-invasive pulse oximetry for the measurement of oxygen saturation in intensive care patients].
Spiss CK; Mauritz W; Zadrobilek E; Draxler V
Anaesthesist; 1985 Aug; 34(8):405-8. PubMed ID: 3931497
[TBL] [Abstract][Full Text] [Related]
31. [Fiberoptic measurement of arterial oxygen saturation in premature and term neonates].
Merz U; Peschgens T; Hörnchen H
Z Geburtshilfe Neonatol; 1999; 203(2):77-80. PubMed ID: 10420515
[TBL] [Abstract][Full Text] [Related]
32. Clinical evaluation of pulse oximetry monitors on critically ill patients.
De Pauw C; Poelaert J; Rolly G; Colardyn F
Acta Anaesthesiol Belg; 1990; 41(1):33-9. PubMed ID: 2360390
[TBL] [Abstract][Full Text] [Related]
33. Accuracy of two ear oximeters at rest and during exercise in pulmonary patients.
Ries AL; Farrow JT; Clausen JL
Am Rev Respir Dis; 1985 Sep; 132(3):685-9. PubMed ID: 4037542
[TBL] [Abstract][Full Text] [Related]
34. Noninvasive oximetry in the rat.
Decker MJ; Conrad KP; Strohl KP
Biomed Instrum Technol; 1989; 23(3):222-8. PubMed ID: 2752232
[TBL] [Abstract][Full Text] [Related]
35. Evaluation of the Datascope ACCUSAT pulse oximeter in healthy adults.
Mendelson Y; Kent JC; Shahnarian A; Welch GW; Giasi RM
J Clin Monit; 1988 Jan; 4(1):59-63. PubMed ID: 3339392
[TBL] [Abstract][Full Text] [Related]
36. Skin reflectance pulse oximetry: in vivo measurements from the forearm and calf.
Mendelson Y; McGinn MJ
J Clin Monit; 1991 Jan; 7(1):7-12. PubMed ID: 1999702
[TBL] [Abstract][Full Text] [Related]
37. Evaluation of the Ohmeda 3700 pulse oximeter.
Warley AR; Mitchell JH; Stradling JR
Thorax; 1987 Nov; 42(11):892-6. PubMed ID: 3424271
[TBL] [Abstract][Full Text] [Related]
38. Ear oximetry in clinical practice.
Chaudhary BA; Burki NK
Am Rev Respir Dis; 1978 Jan; 117(1):173-5. PubMed ID: 619718
[TBL] [Abstract][Full Text] [Related]
39. Evaluation of pulse oximetry in anaesthetised foals using multiple combinations of transducer type and transducer attachment site.
Chaffin MK; Matthews NS; Cohen ND; Carter GK
Equine Vet J; 1996 Nov; 28(6):437-45. PubMed ID: 9049492
[TBL] [Abstract][Full Text] [Related]
40. Evaluation of pulse oximeter probes and probe placement in healthy dogs.
Huss BT; Anderson MA; Branson KR; Wagner-Mann CC; Mann FA
J Am Anim Hosp Assoc; 1995; 31(1):9-14. PubMed ID: 7820772
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]