BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

532 related articles for article (PubMed ID: 24433324)

  • 1. Real-time contact force sensing for pulmonary vein isolation in the setting of paroxysmal atrial fibrillation: procedural and 1-year results.
    Marijon E; Fazaa S; Narayanan K; Guy-Moyat B; Bouzeman A; Providencia R; Treguer F; Combes N; Bortone A; Boveda S; Combes S; Albenque JP
    J Cardiovasc Electrophysiol; 2014 Feb; 25(2):130-7. PubMed ID: 24433324
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Higher contact-force values associated with better mid-term outcome of paroxysmal atrial fibrillation ablation using the SmartTouch™ catheter.
    Providência R; Marijon E; Combes S; Bouzeman A; Jourda F; Khoueiry Z; Cardin C; Combes N; Boveda S; Albenque JP
    Europace; 2015 Jan; 17(1):56-63. PubMed ID: 25280910
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Catheter-tissue contact force values do not impact mid-term clinical outcome following pulmonary vein isolation in patients with paroxysmal atrial fibrillation.
    Stabile G; Solimene F; Calò L; Anselmino M; Castro A; Pratola C; Golia P; Bottoni N; Grandinetti G; De Simone A; Schillaci V; Bertaglia E; De Ponti R
    J Interv Card Electrophysiol; 2015 Jan; 42(1):21-6. PubMed ID: 25378035
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Contact-force guided radiofrequency vs. second-generation balloon cryotherapy for pulmonary vein isolation in patients with paroxysmal atrial fibrillation-a prospective evaluation.
    Jourda F; Providencia R; Marijon E; Bouzeman A; Hireche H; Khoueiry Z; Cardin C; Combes N; Combes S; Boveda S; Albenque JP
    Europace; 2015 Feb; 17(2):225-31. PubMed ID: 25186456
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pulmonary vein isolation using "contact force" ablation: the effect on dormant conduction and long-term freedom from recurrent atrial fibrillation--a prospective study.
    Andrade JG; Monir G; Pollak SJ; Khairy P; Dubuc M; Roy D; Talajic M; Deyell M; Rivard L; Thibault B; Guerra PG; Nattel S; Macle L
    Heart Rhythm; 2014 Nov; 11(11):1919-24. PubMed ID: 25068575
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of Contact Force Monitoring in Acute Pulmonary Vein Isolation Using an Anatomic Approach. A Randomized Study.
    Pedrote A; Arana-Rueda E; Arce-León A; Acosta J; Gómez-Pulido F; Martos-Maine JL; Frutos-López M; Sánchez-Brotons J; García-Riesco L
    Pacing Clin Electrophysiol; 2016 Apr; 39(4):361-9. PubMed ID: 26768692
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: a multicentre European evaluation.
    Squara F; Zhao A; Marijon E; Latcu DG; Providencia R; Di Giovanni G; Jauvert G; Jourda F; Chierchia GB; De Asmundis C; Ciconte G; Alonso C; Grimard C; Boveda S; Cauchemez B; Saoudi N; Brugada P; Albenque JP; Thomas O
    Europace; 2015 May; 17(5):718-24. PubMed ID: 25840289
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Remote-controlled magnetic pulmonary vein isolation using a new three-dimensional non-fluoroscopic navigation system: a single-centre prospective study.
    Da Costa A; Ben H'dech M; Romeyer-Bouchard C; Bisch L; Gate-Martinet A; Levallois M; Isaaz K
    Arch Cardiovasc Dis; 2013; 106(8-9):423-32. PubMed ID: 23906679
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pulmonary vein isolation with a new multipolar irrigated radiofrequency ablation catheter (nMARQ™): feasibility, acute and short-term efficacy, safety, and impact on postablation silent cerebral ischemia.
    Scaglione M; Caponi D; Anselmino M; Di Clemente F; Blandino A; Ferraris F; Di Donna P; Ebrille E; Halimi F; Leclercq JF; Iunco C; Vaudagna C; Cesarani F; Gaita F
    J Cardiovasc Electrophysiol; 2014 Dec; 25(12):1299-305. PubMed ID: 25066687
    [TBL] [Abstract][Full Text] [Related]  

  • 10. EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation.
    Kautzner J; Neuzil P; Lambert H; Peichl P; Petru J; Cihak R; Skoda J; Wichterle D; Wissner E; Yulzari A; Kuck KH
    Europace; 2015 Aug; 17(8):1229-35. PubMed ID: 26041872
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reduced residual conduction gaps and favourable outcome in contact force-guided circumferential pulmonary vein isolation.
    Itoh T; Kimura M; Tomita H; Sasaki S; Owada S; Horiuchi D; Sasaki K; Ishida Y; Kinjo T; Okumura K
    Europace; 2016 Apr; 18(4):531-7. PubMed ID: 26346921
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial.
    Natale A; Reddy VY; Monir G; Wilber DJ; Lindsay BD; McElderry HT; Kantipudi C; Mansour MC; Melby DP; Packer DL; Nakagawa H; Zhang B; Stagg RB; Boo LM; Marchlinski FE
    J Am Coll Cardiol; 2014 Aug; 64(7):647-56. PubMed ID: 25125294
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Remote-controlled magnetic pulmonary vein isolation using a new irrigated-tip catheter in patients with atrial fibrillation.
    Chun KR; Wissner E; Koektuerk B; Konstantinidou M; Schmidt B; Zerm T; Metzner A; Tilz R; Boczor S; Fuernkranz A; Ouyang F; Kuck KH
    Circ Arrhythm Electrophysiol; 2010 Oct; 3(5):458-64. PubMed ID: 20610835
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pulmonary vein isolation using a circular, open irrigated mapping and ablation catheter (nMARQ): a report on feasibility and efficacy.
    Zellerhoff S; Daly M; Lim HS; Denis A; Komatsu Y; Jesel L; Derval N; Sacher F; Cochet H; Knecht S; Yiem S; Hocini M; Haïssaguerre M; Jaïs P
    Europace; 2014 Sep; 16(9):1296-303. PubMed ID: 24942401
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Three-year outcomes and reconnection patterns after initial contact force guided pulmonary vein isolation for paroxysmal atrial fibrillation.
    Nair GM; Yeo C; MacDonald Z; Ainslie MP; Alqarawi WA; Nery PB; Redpath CJ; Sadek M; Spence S; Green MS; Birnie DH
    J Cardiovasc Electrophysiol; 2017 Sep; 28(9):984-993. PubMed ID: 28635046
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical impact of contact force and its regional variability on efficiency and effectiveness of pulmonary vein isolation for atrial fibrillation.
    Sotomi Y; Inoue K; Kikkawa T; Tanaka K; Toyoshima Y; Oka T; Tanaka N; Orihara Y; Iwakura K; Sakata Y; Fujii K
    J Cardiol; 2016 Oct; 68(4):335-41. PubMed ID: 26603325
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Duty-cycled multi-electrode radiofrequency vs. conventional irrigated point-by-point radiofrequency ablation for recurrent atrial fibrillation: comparative 3-year data.
    De Greef Y; Buysschaert I; Schwagten B; Stockman D; Tavernier R; Duytschaever M
    Europace; 2014 Jun; 16(6):820-5. PubMed ID: 24443035
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Single-catheter technique for pulmonary vein antrum isolation: is it sufficient to identify and close the residual gaps without a circular mapping catheter?
    Dong J; Liu X; Long D; Yu R; Tang R; Lü F; Ma C
    J Cardiovasc Electrophysiol; 2009 Mar; 20(3):273-9. PubMed ID: 19175841
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Initial experience with the high-density mesh ablation catheter for pulmonary vein isolation.
    De Greef Y; Stockman D; Duytschaever M; Vandekerckhove Y; Tavernier R
    Pacing Clin Electrophysiol; 2009 Oct; 32(10):1286-93. PubMed ID: 19796345
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Initial impedance decrease as an indicator of good catheter contact: insights from radiofrequency ablation with force sensing catheters.
    Reichlin T; Knecht S; Lane C; Kühne M; Nof E; Chopra N; Tadros TM; Reddy VY; Schaer B; John RM; Osswald S; Stevenson WG; Sticherling C; Michaud GF
    Heart Rhythm; 2014 Feb; 11(2):194-201. PubMed ID: 24177370
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 27.