These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

199 related articles for article (PubMed ID: 24434561)

  • 1. Evaluation of multiple reaction monitoring cubed for the analysis of tachykinin related peptides in rat spinal cord using a hybrid triple quadrupole-linear ion trap mass spectrometer.
    Pailleux F; Beaudry F
    J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Feb; 947-948():164-7. PubMed ID: 24434561
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Identification, characterization and quantification of specific neuropeptides in rat spinal cord by liquid chromatography electrospray quadrupole ion trap mass spectrometry.
    Beaudry F; Ferland CE; Vachon P
    Biomed Chromatogr; 2009 Sep; 23(9):940-50. PubMed ID: 19358311
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Targeted liquid chromatography quadrupole ion trap mass spectrometry analysis of tachykinin related peptides reveals significant expression differences in a rat model of neuropathic pain.
    Pailleux F; Vachon P; Lemoine J; Beaudry F
    Neuropeptides; 2013 Aug; 47(4):261-71. PubMed ID: 23490005
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Absolute quantitation of proteins in human blood by multiplexed multiple reaction monitoring mass spectrometry.
    Percy AJ; Chambers AG; Parker CE; Borchers CH
    Methods Mol Biol; 2013; 1000():167-89. PubMed ID: 23585092
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Liquid chromatography-electrospray linear ion trap mass spectrometry analysis of targeted neuropeptides in Tac1(-/-) mouse spinal cords reveals significant lower concentration of opioid peptides.
    Saidi M; Beaudry F
    Neuropeptides; 2015 Aug; 52():79-87. PubMed ID: 26072188
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-throughput quantification for a drug mixture in rat plasma-a comparison of Ultra Performance liquid chromatography/tandem mass spectrometry with high-performance liquid chromatography/tandem mass spectrometry.
    Yu K; Little D; Plumb R; Smith B
    Rapid Commun Mass Spectrom; 2006; 20(4):544-52. PubMed ID: 16419023
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of substance P in rat spinal cord by high-performance liquid chromatography electrospray quadrupole ion trap mass spectrometry.
    Beaudry F; Vachon P
    Biomed Chromatogr; 2006 Dec; 20(12):1344-50. PubMed ID: 16977591
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High-throughput liquid chromatography/mass spectrometry method for the quantitation of small molecules using accurate mass technologies in supporting discovery drug screening.
    Ding X; Ghobarah H; Zhang X; Jaochico A; Liu X; Deshmukh G; Liederer BM; Hop CE; Dean B
    Rapid Commun Mass Spectrom; 2013 Feb; 27(3):401-8. PubMed ID: 23280971
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Targeted high-resolution quadrupole-Orbitrap mass spectrometry analyses reveal a significant reduction of tachykinin and opioid neuropeptides level in PC1 and PC2 mutant mouse spinal cords.
    Saidi M; Beaudry F
    Neuropeptides; 2017 Oct; 65():37-44. PubMed ID: 28476408
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Investigation of an enhanced resolution triple quadrupole mass spectrometer for high-throughput liquid chromatography/tandem mass spectrometry assays.
    Yang L; Amad M; Winnik WM; Schoen AE; Schweingruber H; Mylchreest I; Rudewicz PJ
    Rapid Commun Mass Spectrom; 2002; 16(21):2060-6. PubMed ID: 12391581
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Rapid screening and characterization of drug metabolites using a multiple ion monitoring-dependent MS/MS acquisition method on a hybrid triple quadrupole-linear ion trap mass spectrometer.
    Yao M; Ma L; Humphreys WG; Zhu M
    J Mass Spectrom; 2008 Oct; 43(10):1364-75. PubMed ID: 18416441
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of neuropeptide K processing in rat spinal cord S9 fractions using high-resolution quadrupole-Orbitrap mass spectrometry.
    Salem JB; Nkambeu B; Beaudry F
    Biomed Chromatogr; 2018 Jun; 32(6):e4204. PubMed ID: 29442375
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Androgen glucuronides analysis by liquid chromatography tandem-mass spectrometry: could it raise new perspectives in the diagnostic field of hormone-dependent malignancies?
    Kalogera E; Pistos C; Provatopoulou X; Athanaselis S; Spiliopoulou C; Gounaris A
    J Chromatogr B Analyt Technol Biomed Life Sci; 2013 Dec; 940():24-34. PubMed ID: 24140653
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of multiple reaction monitoring cubed performed by a quadrupole-linear ion trap mass spectrometer for quantitative determination of 6-sulfatoxymelatonin in urine.
    Lopukhov LV; Balandina AV; Nigmatullina LS; Mullakhmetova AF; Synbulatova GE; Laikov AV; Lopukhov VL; Grigoryeva TV
    J Chromatogr B Analyt Technol Biomed Life Sci; 2022 Feb; 1190():123094. PubMed ID: 35030474
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Multiple molecular forms of tachykinins in rat spinal cord: a study comparing different extraction methods.
    Brodin E; Rosén A; Theodorsson E; Jonczyk A; Sandberg BE; Brodin K
    Regul Pept; 1994 Jul; 52(2):97-110. PubMed ID: 7526421
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Method for rapid metabolite profiling of drug candidates in fresh hepatocytes using liquid chromatography coupled with a hybrid quadrupole linear ion trap.
    Gao H; Materne OL; Howe DL; Brummel CL
    Rapid Commun Mass Spectrom; 2007; 21(22):3683-93. PubMed ID: 17937450
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of a novel substance P inhibitor in human plasma by high-performance liquid chromatography with atmospheric pressure chemical ionization mass spectrometric detection using single and triple quadrupole detectors.
    Constanzer ML; Chavez-Eng CM; Dru J; Kline WF; Matuszewski BK
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Aug; 807(2):243-50. PubMed ID: 15203036
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A hybrid liquid chromatography-mass spectrometry strategy in a forensic laboratory for opioid, cocaine and amphetamine classes in human urine using a hybrid linear ion trap-triple quadrupole mass spectrometer.
    Dowling G; Regan L; Tierney J; Nangle M
    J Chromatogr A; 2010 Oct; 1217(44):6857-66. PubMed ID: 20855077
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Screening and identification of GSH-trapped reactive metabolites using hybrid triple quadruple linear ion trap mass spectrometry.
    Zheng J; Ma L; Xin B; Olah T; Humphreys WG; Zhu M
    Chem Res Toxicol; 2007 May; 20(5):757-66. PubMed ID: 17402749
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Analysis of macrolide antibiotics, using liquid chromatography-mass spectrometry, in food, biological and environmental matrices.
    Wang J
    Mass Spectrom Rev; 2009; 28(1):50-92. PubMed ID: 18785191
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.