These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

209 related articles for article (PubMed ID: 24443053)

  • 1. Anatomical brain imaging at 7T using two-dimensional GRASE.
    Trampel R; Reimer E; Huber L; Ivanov D; Heidemann RM; Schäfer A; Turner R
    Magn Reson Med; 2014 Nov; 72(5):1291-301. PubMed ID: 24443053
    [TBL] [Abstract][Full Text] [Related]  

  • 2. 7T MRI-Histologic Correlation Study of Low Specific Absorption Rate T2-Weighted GRASE Sequences in the Detection of White Matter Involvement in Multiple Sclerosis.
    Bagnato F; Hametner S; Pennell D; Dortch R; Dula AN; Pawate S; Smith SA; Lassmann H; Gore JC; Welch EB
    J Neuroimaging; 2015; 25(3):370-8. PubMed ID: 25898858
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Application of PINS radiofrequency pulses to reduce power deposition in RARE/turbo spin echo imaging of the human head.
    Norris DG; Boyacioğlu R; Schulz J; Barth M; Koopmans PJ
    Magn Reson Med; 2014 Jan; 71(1):44-9. PubMed ID: 24150771
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simultaneous spin-echo refocusing.
    Günther M; Feinberg DA
    Magn Reson Med; 2005 Sep; 54(3):513-23. PubMed ID: 16086300
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Density weighted turbo spin echo imaging.
    Zeller M; Gutberlet M; Stäb D; Ritter CO; Beer M; Hahn D; Köstler H
    J Magn Reson Imaging; 2013 Apr; 37(4):965-73. PubMed ID: 23325699
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Signal-to-noise ratio and MR tissue parameters in human brain imaging at 3, 7, and 9.4 tesla using current receive coil arrays.
    Pohmann R; Speck O; Scheffler K
    Magn Reson Med; 2016 Feb; 75(2):801-9. PubMed ID: 25820458
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Brain MR imaging at ultra-low radiofrequency power.
    Sarkar SN; Alsop DC; Madhuranthakam AJ; Busse RF; Robson PM; Rofsky NM; Hackney DB
    Radiology; 2011 May; 259(2):550-7. PubMed ID: 21357520
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Variable flip angle 3D-GRASE for high resolution fMRI at 7 tesla.
    Kemper VG; De Martino F; Yacoub E; Goebel R
    Magn Reson Med; 2016 Sep; 76(3):897-904. PubMed ID: 26390180
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Brain tumor enhancement in MR imaging at 3 Tesla: comparison of SNR and CNR gain using TSE and GRE techniques.
    Wintersperger BJ; Runge VM; Biswas J; Reiser MF; Schoenberg SO
    Invest Radiol; 2007 Aug; 42(8):558-63. PubMed ID: 17620938
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Increasing robustness of radial GRASE acquisition for SAR-reduced brain imaging.
    Okanovic M; Völker M; Trampel R; Breuer F; Jakob P; Blaimer M
    Z Med Phys; 2018 Aug; 28(3):236-246. PubMed ID: 29580616
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of echo time and T
    Uddin MN; Figley TD; Figley CR
    Magn Reson Imaging; 2018 Sep; 51():35-43. PubMed ID: 29680454
    [TBL] [Abstract][Full Text] [Related]  

  • 12. GRASE: ultra-fast turbo gradient spin-echo sequence. A new approach to fast MR imaging of the musculoskeletal system.
    Trattnig S; Breitenseher M; Kontaxis G; Helbich T; Rand T; Imhof H
    Acta Radiol; 1997 Sep; 38(5):880-4. PubMed ID: 9332249
    [TBL] [Abstract][Full Text] [Related]  

  • 13. K-space trajectories in 3D-GRASE sequence for high resolution structural imaging.
    Cristobal-Huerta A; Poot DHJ; Vogel MW; Krestin GP; Hernandez-Tamames JA
    Magn Reson Imaging; 2018 May; 48():10-19. PubMed ID: 29225108
    [TBL] [Abstract][Full Text] [Related]  

  • 14. 3D isotropic turbo spin-echo intermediate-weighted sequence with refocusing control in knee imaging: comparison study with 3D isotropic fast-field echo sequence.
    Seo JM; Yoon YC; Kwon JW
    Acta Radiol; 2011 Dec; 52(10):1119-24. PubMed ID: 22144425
    [TBL] [Abstract][Full Text] [Related]  

  • 15. SNR-optimized phase-sensitive dual-acquisition turbo spin echo imaging: a fast alternative to FLAIR.
    Lee H; Park J
    Magn Reson Med; 2013 Jul; 70(1):106-16. PubMed ID: 22890939
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Optimizing signal-to-noise ratio of high-resolution parallel single-shot diffusion-weighted echo-planar imaging at ultrahigh field strengths.
    Reischauer C; Vorburger RS; Wilm BJ; Jaermann T; Boesiger P
    Magn Reson Med; 2012 Mar; 67(3):679-90. PubMed ID: 21702067
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improved detection of fMRI activation in the cerebellum at 7T with dielectric pads extending the imaging region of a commercial head coil.
    Vaidya MV; Lazar M; Deniz CM; Haemer GG; Chen G; Bruno M; Sodickson DK; Lattanzi R; Collins CM
    J Magn Reson Imaging; 2018 Aug; 48(2):431-440. PubMed ID: 29357200
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Comparison of fast turbo-spin-echo and gradient- and spin-echo sequences as well as echo planar imaging with conventional spin-echo sequences in MRI of focal liver lesions at 1.0 tesla].
    Jung G; Krahe T; Kugel H; Gieseke J; Walter C; Fischbach R; Landwehr P
    Rofo; 1996 Aug; 165(2):137-43. PubMed ID: 8924665
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fast CPMG-based Bloch-Siegert B(1)+ mapping.
    Basse-Lüsebrink TC; Sturm VJ; Kampf T; Stoll G; Jakob PM
    Magn Reson Med; 2012 Feb; 67(2):405-18. PubMed ID: 21688317
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Neural network enhanced 3D turbo spin echo for MR intracranial vessel wall imaging.
    Zhou Z; Chen S; Balu N; Chu B; Zhao X; Sun J; Mossa-Basha M; Hatsukami T; Börnert P; Yuan C
    Magn Reson Imaging; 2021 May; 78():7-17. PubMed ID: 33548457
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.