BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 2444423)

  • 1. Brain-stem monitoring. I. A system for high-rate sequential BAEP recording and feature extraction.
    Bertrand O; Garcia-Larrea L; Artru F; Mauguière F; Pernier J
    Electroencephalogr Clin Neurophysiol; 1987 Nov; 68(6):433-45. PubMed ID: 2444423
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Brain-stem monitoring. II. Preterminal BAEP changes observed until brain death in deeply comatose patients.
    Garcia-Larrea L; Bertrand O; Artru F; Pernier J; Mauguière F
    Electroencephalogr Clin Neurophysiol; 1987 Nov; 68(6):446-57. PubMed ID: 2444424
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Continuous and simultaneous monitoring of EEG spectra and brainstem auditory and somatosensory evoked potentials in the intensive care unit and the operating room.
    Pfurtscheller G; Schwarz G; Schroettner O; Litscher G; Maresch H; Auer L; List W
    J Clin Neurophysiol; 1987 Oct; 4(4):389-96. PubMed ID: 3680495
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Brain-stem auditory evoked potentials and early somatosensory evoked potentials in neurointensively treated comatose children.
    Lütschg J; Pfenninger J; Ludin HP; Vassella F
    Am J Dis Child; 1983 May; 137(5):421-6. PubMed ID: 6846268
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Acoustically evoked brain stem potentials. Prerequisites for clinical use, data quality and sources of error].
    Litscher G; Pfurtscheller G; Schwarz G; List W
    Anaesthesist; 1987 Oct; 36(10):555-60. PubMed ID: 3688411
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Auditory evoked brain stem potentials--possibilities and problems in the intensive care unit].
    Schwarz G; Pfurtscheller G; List WF
    Anasth Intensivther Notfallmed; 1986 Oct; 21(5):262-5. PubMed ID: 3799948
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The combined monitoring of brain stem auditory evoked potentials and intracranial pressure in coma. A study of 57 patients.
    García-Larrea L; Artru F; Bertrand O; Pernier J; Mauguière F
    J Neurol Neurosurg Psychiatry; 1992 Sep; 55(9):792-8. PubMed ID: 1402970
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Brain-stem auditory-evoked potentials in post-comatose patients after severe closed head trauma.
    Scherg M; von Cramon D; Elton M
    J Neurol; 1984; 231(1):1-5. PubMed ID: 6716105
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Electrophysiologic monitoring in the intensive care unit.
    Hill RA; Chiappa KH
    Can J Neurol Sci; 1994 May; 21(2):S12-6. PubMed ID: 8087728
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The potential role of auditory evoked potentials to assess prognosis in comatose survivors from cardiac arrest.
    De Santis P; Lamanna I; Mavroudakis N; Legros B; Vincent JL; Creteur J; Taccone FS
    Resuscitation; 2017 Nov; 120():119-124. PubMed ID: 28942010
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Evaluation of electrophysiological neuromonitoring in the diagnosis of brain death: Part I. Brainstem auditory evoked potentials].
    Shiogai T
    No To Shinkei; 1989 Jan; 41(1):73-83. PubMed ID: 2719866
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of digital filtering and automatic peak detection to brain stem auditory evoked potential.
    Fridman J; John ER; Bergelson M; Kaiser JB; Baird HW
    Electroencephalogr Clin Neurophysiol; 1982 Apr; 53(4):405-16. PubMed ID: 6175502
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evoked potentials in the ICU.
    Amantini A; Amadori A; Fossi S
    Eur J Anaesthesiol Suppl; 2008; 42():196-202. PubMed ID: 18289442
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Technical requirements for evoked potential monitoring in the intensive care unit.
    Bertrand O; Bohorquez J; Pernier J
    Electroencephalogr Clin Neurophysiol Suppl; 1990; 41():51-70. PubMed ID: 2289454
    [No Abstract]   [Full Text] [Related]  

  • 15. Cerebral monitoring in the operating room and the intensive care unit: an introductory for the clinician and a guide for the novice wanting to open a window to the brain. Part I: The electroencephalogram.
    Freye E; Levy JV
    J Clin Monit Comput; 2005 Apr; 19(1-2):1-76. PubMed ID: 16167222
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mismatch negativity and N100 monitoring: potential clinical value and methodological advances.
    Morlet D; Bouchet P; Fischer C
    Audiol Neurootol; 2000; 5(3-4):198-206. PubMed ID: 10859414
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurements of brain-stem auditory evoked potentials in patients with spontaneous intracerebral hemorrhage.
    Lumenta CB
    J Neurosurg; 1984 Mar; 60(3):548-52. PubMed ID: 6699696
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Brain stem and somatosensory evoked potentials: application in the operating room and intensive care unit.
    Hargadine JR; Snyder E
    Bull Los Angeles Neurol Soc; 1982; 47():62-75. PubMed ID: 7183367
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cerebral monitoring in the operating room and the intensive care unit - an introductory for the clinician and a guide for the novice wanting to open a window to the brain. Part II: Sensory-evoked potentials (SSEP, AEP, VEP).
    Freye E
    J Clin Monit Comput; 2005 Apr; 19(1-2):77-168. PubMed ID: 16167223
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Multimodal cerebral monitoring in comatose head-injured patients.
    Bardt TF; Unterberg AW; Kiening KL; Schneider GH; Lanksch WR
    Acta Neurochir (Wien); 1998; 140(4):357-65. PubMed ID: 9689327
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.