BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

275 related articles for article (PubMed ID: 24445231)

  • 1. Inductive coupling links for lowest misalignment effects in transcutaneous implanted devices.
    Abbas SM; Hannan MA; Samad SA; Hussain A
    Biomed Tech (Berl); 2014 Jun; 59(3):257-68. PubMed ID: 24445231
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improvement of wireless power transmission efficiency of implantable subcutaneous devices by closed magnetic circuit mechanism.
    Jo SE; Joung S; Suh JK; Kim YJ
    Med Biol Eng Comput; 2012 Sep; 50(9):973-80. PubMed ID: 22806430
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Analysis and optimization of spiral circular inductive coupling link for bio-implanted applications on air and within human tissue.
    Mutashar S; Hannan MA; Samad SA; Hussain A
    Sensors (Basel); 2014 Jun; 14(7):11522-41. PubMed ID: 24984057
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Electromagnetic compatibility and safety design of a patient compliance-free, inductive implant charger.
    Theodoridis MP; Mollov SV
    Biomed Tech (Berl); 2014 Oct; 59(5):461-9. PubMed ID: 24815050
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Far-field RF powering of implantable devices: safety considerations.
    Bercich RA; Duffy DR; Irazoqui PP
    IEEE Trans Biomed Eng; 2013 Aug; 60(8):2107-12. PubMed ID: 23412566
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Distant energy transfer for artificial human implants.
    Theodoridis MP; Mollov SV
    IEEE Trans Biomed Eng; 2005 Nov; 52(11):1931-8. PubMed ID: 16285397
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Wireless charing pillow for a fully implantable hearing aid: Design of a circular array coil based on finite element analysis for reducing magnetic weak zones.
    Lim HG; Kim JH; Shin DH; Woo ST; Seong KW; Lee JH; Kim MN; Wei Q; Cho JH
    Biomed Mater Eng; 2015; 26 Suppl 1():S1741-7. PubMed ID: 26405942
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Downsizing of coreless coils for transcutaneous energy transmission in implantable devices - improvement of coupling factor and efficiency between coils.
    Seshimo T; Yamamoto T; Koshiji K
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1871-4. PubMed ID: 24110076
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Wireless power transfer analysis of circular and spherical coils under misalignment conditions for biomedical implants.
    Palagani Y; Mohanarangam K; Shim JH; Choi JR
    Biosens Bioelectron; 2019 Sep; 141():111283. PubMed ID: 31295707
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Efficiency optimization of class-D biomedical inductive wireless power transfer systems by means of frequency adjustment.
    Schormans M; Valente V; Demosthenous A
    Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():5473-6. PubMed ID: 26737530
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optimal Design of Litz Wire Coils With Sandwich Structure Wirelessly Powering an Artificial Anal Sphincter System.
    Ke L; Yan G; Yan S; Wang Z; Li X
    Artif Organs; 2015 Jul; 39(7):615-26. PubMed ID: 25808086
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis and Optimization of Four-Coil Planar Magnetically Coupled Printed Spiral Resonators.
    Khan SR; Choi G
    Sensors (Basel); 2016 Aug; 16(8):. PubMed ID: 27527169
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Noninvasive control of the power transferred to an implanted device by an ultrasonic transcutaneous energy transfer link.
    Shmilovitz D; Ozeri S; Wang CC; Spivak B
    IEEE Trans Biomed Eng; 2014 Apr; 61(4):995-1004. PubMed ID: 24013825
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The re-design at the transformer portion of transcutaneous energy transmission system for all implantable devices.
    Watada M; Saisho R; Kim YJ; Ohuchi K; Takatani S; Um YS
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():1035-8. PubMed ID: 18002137
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optimal frequency for powering millimeter-sized biomedical implants inside an inductively-powered homecage.
    Gougheri HS; Kiani M
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():4804-4807. PubMed ID: 28269345
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Modeling Endovascular MRI Coil Coupling With Transmit RF Excitation.
    Venkateswaran M; Unal O; Hurley S; Samsonov A; Wang P; Fain SB; Kurpad KN
    IEEE Trans Biomed Eng; 2017 Jan; 64(1):70-77. PubMed ID: 26960218
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simulative and experimental research on wireless power transmission technique in implantable medical device.
    Yu Y; Hao H; Wang W; Li L
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():923-6. PubMed ID: 19963736
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Misalignment tolerable coil structure for biomedical applications with wireless power transfer.
    Chow JP; Chen N; Chung HS; Chan LL
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():775-8. PubMed ID: 24109802
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of system integration and packaging on its inductive power link for an integrated wireless neural interface.
    Kim S; Harrison RR; Solzbacher F
    IEEE Trans Biomed Eng; 2009 Dec; 56(12):2927-36. PubMed ID: 19695994
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In Vivo Magnetic Stimulation of Rat Sciatic Nerve With Centimeter- and Millimeter-Scale Solenoid Coils.
    Kagan ZB; RamRakhyani AK; Lazzi G; Normann RA; Warren DJ
    IEEE Trans Neural Syst Rehabil Eng; 2016 Nov; 24(11):1138-1147. PubMed ID: 27019496
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.