These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 2444942)

  • 1. A special outpatient clinic for following patients with implanted tachyarrhythmia devices.
    Galasso D; Gallagher R; Parsonnet V; Rothbart S; Calvo R; Saksena S
    Pacing Clin Electrophysiol; 1987 Sep; 10(5):1168-74. PubMed ID: 2444942
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Efficacy of automatic multimodal device therapy for ventricular tachyarrhythmias as delivered by a new implantable pacing cardioverter-defibrillator. Results of a European multicenter study of 102 implants.
    Fromer M; Brachmann J; Block M; Siebels J; Hoffmann E; Almendral J; Ohm OJ; den Dulk K; Coumel P; Camm AJ
    Circulation; 1992 Aug; 86(2):363-74. PubMed ID: 1638705
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Automatic implantable cardioverter-defibrillator (AICD) and antitachycardia pacemaker (Tachylog 651) in the treatment of ventricular tachyarrhythmias].
    Gerckens U; Manz M; Funke HD; Kirchhoff PG; Lüderitz B
    Z Kardiol; 1987 Apr; 76(4):211-6. PubMed ID: 3604373
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical experience with implantable devices for control of tachyarrhythmias.
    Den Dulk K; Bertholet M; Brugada P; Bär FW; Demoulin JC; Waleffe A; Bakels N; Lindemans F; Bourgeois I; Kulbertus HE
    Pacing Clin Electrophysiol; 1984 May; 7(3 Pt 2):548-56. PubMed ID: 6204313
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Automatic implantable cardioverter/defibrillator (AICD) and antitachycardia pacemaker (Tachylog): combined use in ventricular tachyarrhythmias.
    Lüderitz B; Gerckens U; Manz M
    Pacing Clin Electrophysiol; 1986 Nov; 9(6 Pt 2):1356-60. PubMed ID: 2432562
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Combination of antitachycardia pacemaker and automatic implantable cardioverter/defibrillator for ventricular tachycardia.
    Manz M; Gerckens U; Funke HD; Kirchhoff PG; Lüderitz B
    Pacing Clin Electrophysiol; 1986 Sep; 9(5):676-84. PubMed ID: 2429273
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reduction in defibrillator shocks with an implantable device combining antitachycardia pacing and shock therapy.
    Leitch JW; Gillis AM; Wyse DG; Yee R; Klein GJ; Guiraudon G; Sheldon RS; Duff HJ; Kieser TM; Mitchell LB
    J Am Coll Cardiol; 1991 Jul; 18(1):145-51. PubMed ID: 2050917
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Role of antitachycardia devices in the treatment of ventricular tachyarrhythmias.
    Lüderitz B; Manz M
    Am J Cardiol; 1989 Dec; 64(20):75J-78J. PubMed ID: 2596414
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Significance of supraventricular tachyarrhythmias in patients with implanted pacing cardioverter defibrillators.
    Schmitt C; Montero M; Melichercik J
    Pacing Clin Electrophysiol; 1994 Mar; 17(3 Pt 1):295-302. PubMed ID: 7513854
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Detection of cardiac tachyarrhythmias in implantable devices.
    Gillberg J
    J Electrocardiol; 2007; 40(6 Suppl):S123-8. PubMed ID: 17993309
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The impact of antitachycardia pacing with defibrillation.
    Lüderitz B
    Pacing Clin Electrophysiol; 1991 Feb; 14(2 Pt 2):312-6. PubMed ID: 1706844
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Anti-tachycardia radiofrequency pacemakers. Experience with 44 cases].
    Fontaine G; Moro-Serrano C; Menezes-Falcao L; Todorova M; Frank R; Tonet JL; Grosgogeat Y
    Arch Mal Coeur Vaiss; 1986 Nov; 79(12):1696-702. PubMed ID: 3105481
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Long-term efficacy of antitachycardia pacing for supraventricular and ventricular tachycardias.
    Fisher JD; Johnston DR; Furman S; Mercando AD; Kim SG
    Am J Cardiol; 1987 Dec; 60(16):1311-6. PubMed ID: 3687782
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Termination of sustained ventricular tachycardia with a new antitachycardia pacemaker: role of the nonautomatic mode to follow pacemaker function.
    Fromer M; Kus T; Page P; Shenasa M
    Can J Cardiol; 1989; 5(1):42-6. PubMed ID: 2920305
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Long-term antitachycardia pacing experience for supraventricular tachycardia.
    den Dulk K; Brugada P; Smeets JL; Wellens HJ
    Pacing Clin Electrophysiol; 1990 Aug; 13(8):1020-30. PubMed ID: 1697949
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Externally activated antitachycardia pacemaker with noninvasive electrophysiologic re-testing capability.
    Aonuma K; Rozanski JJ; Barold SS; DeWitt PL; Gosselin AJ; Lister JW
    Pacing Clin Electrophysiol; 1985 Mar; 8(2):215-24. PubMed ID: 2580282
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Therapeutic pacing in tachyarrhythmias by implanted pacemakers.
    Lüderitz B; d'Alnoncourt CN; Steinbeck G; Beyer J
    Pacing Clin Electrophysiol; 1982 May; 5(3):366-71. PubMed ID: 6179055
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Implantable electrical devices in the management of tachyarrhythmias.
    de Belder MA; Camm AJ
    Clin Cardiol; 1989 Aug; 12(8):461-8. PubMed ID: 2670384
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Device interaction--antitachycardia pacemakers and defibrillators for sustained ventricular tachycardia.
    Ahern TS; Nydegger C; McCormick DJ; Marinchak R; Kowey P; Horowitz LN; Worley S; Kutalek SP
    Pacing Clin Electrophysiol; 1991 Feb; 14(2 Pt 2):302-7. PubMed ID: 1706842
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Device therapy of ventricular tachyarrhythmias.
    Rosenfeld LE
    Cardiol Clin; 1988 Aug; 6(3):437-48. PubMed ID: 3073009
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.