465 related articles for article (PubMed ID: 24460051)
21. Diagnostic accuracy of motor evoked potentials to detect neurological deficit during idiopathic scoliosis correction: a systematic review.
Thirumala PD; Crammond DJ; Loke YK; Cheng HL; Huang J; Balzer JR
J Neurosurg Spine; 2017 Mar; 26(3):374-383. PubMed ID: 27935448
[TBL] [Abstract][Full Text] [Related]
22. An evaluation of multimodal spinal cord monitoring in scoliosis surgery: a single centre experience of 354 operations.
Bhagat S; Durst A; Grover H; Blake J; Lutchman L; Rai AS; Crawford R
Eur Spine J; 2015 Jul; 24(7):1399-407. PubMed ID: 25618452
[TBL] [Abstract][Full Text] [Related]
23. Intraoperative spinal cord monitoring: Lesional level diagnosis.
Gavaret M; Pesenti S; Diop-Sene MS; Choufani E; Bollini G; Jouve JL
Orthop Traumatol Surg Res; 2017 Feb; 103(1):33-38. PubMed ID: 27988240
[TBL] [Abstract][Full Text] [Related]
24. Predictive value of intraoperative neurophysiological monitoring during cervical spine surgery: a prospective analysis of 1055 consecutive patients.
Kelleher MO; Tan G; Sarjeant R; Fehlings MG
J Neurosurg Spine; 2008 Mar; 8(3):215-21. PubMed ID: 18312072
[TBL] [Abstract][Full Text] [Related]
25. Combined monitoring of motor and somatosensory evoked potentials in orthopaedic spinal surgery.
Pelosi L; Lamb J; Grevitt M; Mehdian SM; Webb JK; Blumhardt LD
Clin Neurophysiol; 2002 Jul; 113(7):1082-91. PubMed ID: 12088704
[TBL] [Abstract][Full Text] [Related]
26. Factors related to false- versus true-positive neuromonitoring changes in adolescent idiopathic scoliosis surgery.
Noonan KJ; Walker T; Feinberg JR; Nagel M; Didelot W; Lindseth R
Spine (Phila Pa 1976); 2002 Apr; 27(8):825-30. PubMed ID: 11935104
[TBL] [Abstract][Full Text] [Related]
27. Efficacy of intraoperative monitoring for pediatric patients with spinal cord pathology undergoing spinal deformity surgery.
Wilson-Holden TJ; Padberg AM; Lenke LG; Larson BJ; Bridwell KH; Bassett GS
Spine (Phila Pa 1976); 1999 Aug; 24(16):1685-92. PubMed ID: 10472103
[TBL] [Abstract][Full Text] [Related]
28. Neuromonitoring Changes in Spinal Deformity Surgery.
Kramer S; Ford L; Walsh J
Orthop Clin North Am; 2024 Jan; 55(1):89-99. PubMed ID: 37980106
[TBL] [Abstract][Full Text] [Related]
29. Intraoperative neurophysiological monitoring during spine surgery: a review.
Gonzalez AA; Jeyanandarajan D; Hansen C; Zada G; Hsieh PC
Neurosurg Focus; 2009 Oct; 27(4):E6. PubMed ID: 19795955
[TBL] [Abstract][Full Text] [Related]
30. What Is the Frequency of Intraoperative Alerts During Pediatric Spinal Deformity Surgery Using Current Neuromonitoring Methodology? A Retrospective Study of 218 Surgical Procedures.
Polly DW; Rice K; Tamkus A
Neurodiagn J; 2016 Mar; 56(1):17-31. PubMed ID: 27180504
[TBL] [Abstract][Full Text] [Related]
31. Neuromonitoring for scoliosis surgery.
Glover CD; Carling NP
Anesthesiol Clin; 2014 Mar; 32(1):101-14. PubMed ID: 24491652
[TBL] [Abstract][Full Text] [Related]
32. Transcranial Motor Evoked Potentials during Spinal Deformity Corrections-Safety, Efficacy, Limitations, and the Role of a Checklist.
Acharya S; Palukuri N; Gupta P; Kohli M
Front Surg; 2017; 4():8. PubMed ID: 28243591
[TBL] [Abstract][Full Text] [Related]
33. Frequent neuromonitoring loss during the completion of vertebral column resections in severe spinal deformity surgery.
Wang S; Yang Y; Zhang J; Tian Y; Shen J; Wang S
Spine J; 2017 Jan; 17(1):76-80. PubMed ID: 27497889
[TBL] [Abstract][Full Text] [Related]
34. Responding to neuromonitoring changes in 3-column posterior spinal osteotomies for rigid pediatric spinal deformities.
Jarvis JG; Strantzas S; Lipkus M; Holmes LM; Dear T; Magana S; Lebel DE; Lewis SJ
Spine (Phila Pa 1976); 2013 Apr; 38(8):E493-503. PubMed ID: 23354113
[TBL] [Abstract][Full Text] [Related]
35. Intraoperative monitoring in pediatric orthopedic spinal surgery: three hundred consecutive monitoring cases of which 10% of patients were younger than 4 years of age.
Gavaret M; Trébuchon A; Aubert S; Jacopin S; Blondel B; Glard Y; Jouve JL; Bollini G
Spine (Phila Pa 1976); 2011 Oct; 36(22):1855-63. PubMed ID: 21270706
[TBL] [Abstract][Full Text] [Related]
36. Somatosensory- and motor-evoked potential monitoring without a wake-up test during idiopathic scoliosis surgery. An accepted standard of care.
Padberg AM; Wilson-Holden TJ; Lenke LG; Bridwell KH
Spine (Phila Pa 1976); 1998 Jun; 23(12):1392-400. PubMed ID: 9654631
[TBL] [Abstract][Full Text] [Related]
37. Multimodal Intraoperative Spinal Cord Monitoring during Spinal Deformity Surgery: Efficacy, Diagnostic Characteristics, and Algorithm Development.
Tsirikos AI; Duckworth AD; Henderson LE; Michaelson C
Med Princ Pract; 2020; 29(1):6-17. PubMed ID: 31158841
[TBL] [Abstract][Full Text] [Related]
38. The Recognition, Incidence, and Management of Spinal Cord Monitoring Alerts in Early-onset Scoliosis Surgery.
Phillips JH; Palmer RC; Lopez D; Knapp DR; Herrera-Soto J; Isley M
J Pediatr Orthop; 2017 Dec; 37(8):e581-e587. PubMed ID: 27280893
[TBL] [Abstract][Full Text] [Related]
39. Multimodality monitoring of transcranial electric motor and somatosensory-evoked potentials during surgical correction of spinal deformity in patients with cerebral palsy and other neuromuscular disorders.
DiCindio S; Theroux M; Shah S; Miller F; Dabney K; Brislin RP; Schwartz D
Spine (Phila Pa 1976); 2003 Aug; 28(16):1851-5; discussion 1855-6. PubMed ID: 12923474
[TBL] [Abstract][Full Text] [Related]
40. Editorial: Intraoperative neurophysiological monitoring and spinal deformity surgery.
Jea A
J Neurosurg Pediatr; 2014 Mar; 13(3):245-6. PubMed ID: 24460050
[No Abstract] [Full Text] [Related]