These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
224 related articles for article (PubMed ID: 24461048)
1. Fast, simple, and informative patient-specific dose verification method for intensity modulated total marrow irradiation with helical tomotherapy. Takahashi Y; Hui SK Radiat Oncol; 2014 Jan; 9():34. PubMed ID: 24461048 [TBL] [Abstract][Full Text] [Related]
2. Feasibility study of helical tomotherapy for total body or total marrow irradiation. Hui SK; Kapatoes J; Fowler J; Henderson D; Olivera G; Manon RR; Gerbi B; Mackie TR; Welsh JS Med Phys; 2005 Oct; 32(10):3214-24. PubMed ID: 16279075 [TBL] [Abstract][Full Text] [Related]
3. Leaf open time sinogram (LOTS): a novel approach for patient specific quality assurance of total marrow irradiation. Thiyagarajan R; Sharma DS; Kaushik S; Sawant M; Ganapathy K; Nambi Raj NA; Chilukuri S; Sundar SC; Patro KC; Manikandan A; Noufal MP; Sivaraman R; Easow J; Jalali R Radiat Oncol; 2020 Oct; 15(1):236. PubMed ID: 33054792 [TBL] [Abstract][Full Text] [Related]
4. Independent calculation of dose distributions for helical tomotherapy using a conventional treatment planning system. Klüter S; Schubert K; Lissner S; Sterzing F; Oetzel D; Debus J; Schlegel W; Oelfke U; Nill S Med Phys; 2014 Aug; 41(8):081709. PubMed ID: 25086519 [TBL] [Abstract][Full Text] [Related]
5. Clinical implementation of Dosimetry Check™ for TomoTherapy Chung E; Kwon D; Park T; Kang H; Chung Y J Appl Clin Med Phys; 2018 Nov; 19(6):193-199. PubMed ID: 30354001 [TBL] [Abstract][Full Text] [Related]
6. Impact of very long time output variation in the treatment of total marrow irradiation with helical tomotherapy. Takahashi Y; Hui SK Radiat Oncol; 2013 May; 8():123. PubMed ID: 23688298 [TBL] [Abstract][Full Text] [Related]
7. Dosimetric comparison of helical tomotherapy treatment plans for total marrow irradiation created using GPU and CPU dose calculation engines. Nalichowski A; Burmeister J Med Phys; 2013 Jul; 40(7):071716. PubMed ID: 23822420 [TBL] [Abstract][Full Text] [Related]
8. Feasibility study on dosimetry verification of volumetric-modulated arc therapy-based total marrow irradiation. Liang Y; Kim GY; Pawlicki T; Mundt AJ; Mell LK J Appl Clin Med Phys; 2013 Mar; 14(2):3852. PubMed ID: 23470926 [TBL] [Abstract][Full Text] [Related]
9. Dosimetric verification of dose calculation algorithm in the lung during total marrow irradiation using helical tomotherapy. Konstanty E; Malicki J; Łagodowska K; Kowalik A J Cancer Res Ther; 2017; 13(1):33-37. PubMed ID: 28508830 [TBL] [Abstract][Full Text] [Related]
10. [Effects of Phantom Factor on Shape Differences in Tomotherapy Water-equivalent Phantoms]. Ishita K; Tanabe Y; Sawahashi M; Yonaiguchi J; Takeda M; Sokawa T; Suenaga M; Abe K; Suzuki R; Sato Y Nihon Hoshasen Gijutsu Gakkai Zasshi; 2023 May; 79(5):462-468. PubMed ID: 36889732 [TBL] [Abstract][Full Text] [Related]
11. [Patient-specific dose verification method using ArcCHECK for total marrow irradiation with intensity modulated arc therapy]. Xie C; Xu S; Xu W; Cong X; Ge R; Gong H; Ju Z; Dai X Zhongguo Yi Liao Qi Xie Za Zhi; 2015 Jan; 39(1):68-71. PubMed ID: 26027301 [TBL] [Abstract][Full Text] [Related]
12. Phantomless patient-specific TomoTherapy QA via delivery performance monitoring and a secondary Monte Carlo dose calculation. Handsfield LL; Jones R; Wilson DD; Siebers JV; Read PW; Chen Q Med Phys; 2014 Oct; 41(10):101703. PubMed ID: 25281942 [TBL] [Abstract][Full Text] [Related]
13. Clinical implementation of an exit detector-based dose reconstruction tool for helical tomotherapy delivery quality assurance. Deshpande S; Xing A; Metcalfe P; Holloway L; Vial P; Geurts M Med Phys; 2017 Oct; 44(10):5457-5466. PubMed ID: 28737014 [TBL] [Abstract][Full Text] [Related]
14. Measurement-guided volumetric dose reconstruction for helical tomotherapy. Stambaugh C; Nelms B; Wolf T; Mueller R; Geurts M; Opp D; Moros E; Zhang G; Feygelman V J Appl Clin Med Phys; 2015 Mar; 16(2):5298. PubMed ID: 26103199 [TBL] [Abstract][Full Text] [Related]
15. Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification. McDermott LN; Wendling M; van Asselen B; Stroom J; Sonke JJ; van Herk M; Mijnheer BJ Med Phys; 2006 Oct; 33(10):3921-30. PubMed ID: 17089854 [TBL] [Abstract][Full Text] [Related]
16. Total marrow irradiation versus total body irradiation using intensity-modulated helical tomotherapy. Köksal M; Kersting L; Schoroth F; Garbe S; Koch D; Scafa D; Sarria GR; Leitzen C; Heine A; Holderried T; Brossart P; Zoga E; Attenberger U; Schmeel LC J Cancer Res Clin Oncol; 2023 Aug; 149(9):5965-5973. PubMed ID: 36607428 [TBL] [Abstract][Full Text] [Related]
17. Design and implementation of a "cheese" phantom-based Tomotherapy TLD dose intercomparison. Schiefer H; Buchauer K; Heinze S; Henke G; Plasswilm L Strahlenther Onkol; 2015 Nov; 191(11):855-61. PubMed ID: 26087907 [TBL] [Abstract][Full Text] [Related]
18. Dose verification of virtual bolus application for helical tomotherapy. Nwe SY; Chitapanarux I; Nobnop W Med Dosim; 2023 Spring; 48(1):16-19. PubMed ID: 36307296 [TBL] [Abstract][Full Text] [Related]
19. Total marrow irradiation with RapidArc volumetric arc therapy. Aydogan B; Yeginer M; Kavak GO; Fan J; Radosevich JA; Gwe-Ya K Int J Radiat Oncol Biol Phys; 2011 Oct; 81(2):592-9. PubMed ID: 21345619 [TBL] [Abstract][Full Text] [Related]
20. Dosimetric evaluation of total marrow irradiation using 2 different planning systems. Nalichowski A; Eagle DG; Burmeister J Med Dosim; 2016; 41(3):230-5. PubMed ID: 27372384 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]