BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

226 related articles for article (PubMed ID: 24461048)

  • 1. Fast, simple, and informative patient-specific dose verification method for intensity modulated total marrow irradiation with helical tomotherapy.
    Takahashi Y; Hui SK
    Radiat Oncol; 2014 Jan; 9():34. PubMed ID: 24461048
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Feasibility study of helical tomotherapy for total body or total marrow irradiation.
    Hui SK; Kapatoes J; Fowler J; Henderson D; Olivera G; Manon RR; Gerbi B; Mackie TR; Welsh JS
    Med Phys; 2005 Oct; 32(10):3214-24. PubMed ID: 16279075
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Leaf open time sinogram (LOTS): a novel approach for patient specific quality assurance of total marrow irradiation.
    Thiyagarajan R; Sharma DS; Kaushik S; Sawant M; Ganapathy K; Nambi Raj NA; Chilukuri S; Sundar SC; Patro KC; Manikandan A; Noufal MP; Sivaraman R; Easow J; Jalali R
    Radiat Oncol; 2020 Oct; 15(1):236. PubMed ID: 33054792
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Independent calculation of dose distributions for helical tomotherapy using a conventional treatment planning system.
    Klüter S; Schubert K; Lissner S; Sterzing F; Oetzel D; Debus J; Schlegel W; Oelfke U; Nill S
    Med Phys; 2014 Aug; 41(8):081709. PubMed ID: 25086519
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical implementation of Dosimetry Check™ for TomoTherapy
    Chung E; Kwon D; Park T; Kang H; Chung Y
    J Appl Clin Med Phys; 2018 Nov; 19(6):193-199. PubMed ID: 30354001
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of very long time output variation in the treatment of total marrow irradiation with helical tomotherapy.
    Takahashi Y; Hui SK
    Radiat Oncol; 2013 May; 8():123. PubMed ID: 23688298
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dosimetric comparison of helical tomotherapy treatment plans for total marrow irradiation created using GPU and CPU dose calculation engines.
    Nalichowski A; Burmeister J
    Med Phys; 2013 Jul; 40(7):071716. PubMed ID: 23822420
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Feasibility study on dosimetry verification of volumetric-modulated arc therapy-based total marrow irradiation.
    Liang Y; Kim GY; Pawlicki T; Mundt AJ; Mell LK
    J Appl Clin Med Phys; 2013 Mar; 14(2):3852. PubMed ID: 23470926
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetric verification of dose calculation algorithm in the lung during total marrow irradiation using helical tomotherapy.
    Konstanty E; Malicki J; Łagodowska K; Kowalik A
    J Cancer Res Ther; 2017; 13(1):33-37. PubMed ID: 28508830
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Effects of Phantom Factor on Shape Differences in Tomotherapy Water-equivalent Phantoms].
    Ishita K; Tanabe Y; Sawahashi M; Yonaiguchi J; Takeda M; Sokawa T; Suenaga M; Abe K; Suzuki R; Sato Y
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2023 May; 79(5):462-468. PubMed ID: 36889732
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Patient-specific dose verification method using ArcCHECK for total marrow irradiation with intensity modulated arc therapy].
    Xie C; Xu S; Xu W; Cong X; Ge R; Gong H; Ju Z; Dai X
    Zhongguo Yi Liao Qi Xie Za Zhi; 2015 Jan; 39(1):68-71. PubMed ID: 26027301
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Phantomless patient-specific TomoTherapy QA via delivery performance monitoring and a secondary Monte Carlo dose calculation.
    Handsfield LL; Jones R; Wilson DD; Siebers JV; Read PW; Chen Q
    Med Phys; 2014 Oct; 41(10):101703. PubMed ID: 25281942
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical implementation of an exit detector-based dose reconstruction tool for helical tomotherapy delivery quality assurance.
    Deshpande S; Xing A; Metcalfe P; Holloway L; Vial P; Geurts M
    Med Phys; 2017 Oct; 44(10):5457-5466. PubMed ID: 28737014
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measurement-guided volumetric dose reconstruction for helical tomotherapy.
    Stambaugh C; Nelms B; Wolf T; Mueller R; Geurts M; Opp D; Moros E; Zhang G; Feygelman V
    J Appl Clin Med Phys; 2015 Mar; 16(2):5298. PubMed ID: 26103199
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
    McDermott LN; Wendling M; van Asselen B; Stroom J; Sonke JJ; van Herk M; Mijnheer BJ
    Med Phys; 2006 Oct; 33(10):3921-30. PubMed ID: 17089854
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Total marrow irradiation versus total body irradiation using intensity-modulated helical tomotherapy.
    Köksal M; Kersting L; Schoroth F; Garbe S; Koch D; Scafa D; Sarria GR; Leitzen C; Heine A; Holderried T; Brossart P; Zoga E; Attenberger U; Schmeel LC
    J Cancer Res Clin Oncol; 2023 Aug; 149(9):5965-5973. PubMed ID: 36607428
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design and implementation of a "cheese" phantom-based Tomotherapy TLD dose intercomparison.
    Schiefer H; Buchauer K; Heinze S; Henke G; Plasswilm L
    Strahlenther Onkol; 2015 Nov; 191(11):855-61. PubMed ID: 26087907
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dose verification of virtual bolus application for helical tomotherapy.
    Nwe SY; Chitapanarux I; Nobnop W
    Med Dosim; 2023 Spring; 48(1):16-19. PubMed ID: 36307296
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Total marrow irradiation with RapidArc volumetric arc therapy.
    Aydogan B; Yeginer M; Kavak GO; Fan J; Radosevich JA; Gwe-Ya K
    Int J Radiat Oncol Biol Phys; 2011 Oct; 81(2):592-9. PubMed ID: 21345619
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dosimetric evaluation of total marrow irradiation using 2 different planning systems.
    Nalichowski A; Eagle DG; Burmeister J
    Med Dosim; 2016; 41(3):230-5. PubMed ID: 27372384
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.