259 related articles for article (PubMed ID: 24471791)
1. Total protein measurement in canine cerebrospinal fluid: agreement between a turbidimetric assay and 2 dye-binding methods and determination of reference intervals using an indirect a posteriori method.
Riond B; Steffen F; Schmied O; Hofmann-Lehmann R; Lutz H
Vet Clin Pathol; 2014 Mar; 43(1):78-88. PubMed ID: 24471791
[TBL] [Abstract][Full Text] [Related]
2. Protein determination in cerebrospinal fluid by protein dye-binding assay.
Marshall T; Williams KM
Br J Biomed Sci; 2000; 57(4):281-6. PubMed ID: 11204856
[TBL] [Abstract][Full Text] [Related]
3. Total protein determination in urine: elimination of a differential response between the coomassie blue and pyrogallol red protein dye-binding assays.
Marshall T; Williams KM
Clin Chem; 2000 Mar; 46(3):392-8. PubMed ID: 10702527
[TBL] [Abstract][Full Text] [Related]
4. Protein concentration of cerebrospinal fluid by precipitation with Pyrogallol Red prior to sodium dodecyl sulphate-polyacrylamide gel electrophoresis.
Williams KM; Marshall T
J Biochem Biophys Methods; 2001 Feb; 47(3):197-207. PubMed ID: 11245891
[TBL] [Abstract][Full Text] [Related]
5. Interference in the Coomassie Brilliant Blue and Pyrogallol Red protein dye-binding assays is increased by the addition of sodium dodecyl sulfate to the dye reagents.
Marshall T; Williams KM
Anal Biochem; 2004 Aug; 331(2):255-9. PubMed ID: 15265730
[TBL] [Abstract][Full Text] [Related]
6. Measurement of proteinuria in dogs: analytic and diagnostic differences using 2 laboratory methods.
Rossi G; Bertazzolo W; Binnella M; Scarpa P; Paltrinieri S
Vet Clin Pathol; 2016 Sep; 45(3):450-8. PubMed ID: 27564569
[TBL] [Abstract][Full Text] [Related]
7. [Determination of cerebrospinal fluid proteins using the Cobas Fara centrifugal analyser. Adaptation of the turbidimetric technic to benzethonium chloride].
Guérin JL; Favre G; Raynal G; Soula G
Ann Biol Clin (Paris); 1990; 48(3):167-70. PubMed ID: 2353748
[TBL] [Abstract][Full Text] [Related]
8. [Valve of the use of benzethonium chloride for turbidimetric analysis of cerebrospinal fluid proteins with an automatic analyzer].
Flachaire E; Later R; Caudie C; Quincy C
Ann Biol Clin (Paris); 1983; 41(1):39-44. PubMed ID: 6869941
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of an automated pyrogallol red-molybdate method for the measurement of urinary protein in rats.
Lynch KM; Sellers TS; Gossett KA
Eur J Clin Chem Clin Biochem; 1996 Jul; 34(7):569-71. PubMed ID: 8864407
[TBL] [Abstract][Full Text] [Related]
10. Heparin interference in the cerebrospinal fluid protein assay measured with a pyrogallol red-molybdate complex.
Yang JY; Chien TI; Lu JY; Kao JT
Clin Chim Acta; 2009 Oct; 408(1-2):75-8. PubMed ID: 19646428
[TBL] [Abstract][Full Text] [Related]
11. [Determination of protein in cerebrospinal fluid: comparison of the Coomassie-Blue method and the Cu-Folin differential test].
Schnell R; Jegge S; Rieder HP
J Clin Chem Clin Biochem; 1983 Mar; 21(3):151-5. PubMed ID: 6854226
[TBL] [Abstract][Full Text] [Related]
12. Is standardization more important than methodology for assay of total protein in cerebrospinal fluid?
Gerbaut L; Macart M
Clin Chem; 1986 Feb; 32(2):353-5. PubMed ID: 3943199
[TBL] [Abstract][Full Text] [Related]
13. Standardization of the Coomassie Blue method for cerebrospinal fluid proteins.
Johnson JA; Lott HA
Clin Chem; 1978 Nov; 24(11):1931-3. PubMed ID: 709824
[TBL] [Abstract][Full Text] [Related]
14. Nephelometric determination of total protein in cerebrospinal fluid and urine using benzalkonium chloride as precipitation reagent.
Shephard MD; Whiting MJ
Ann Clin Biochem; 1992 Jul; 29 ( Pt 4)():411-7. PubMed ID: 1642447
[TBL] [Abstract][Full Text] [Related]
15. Automated determination of urine and cerebrospinal fluid proteins with Coomassie Brilliant Blue and the Abbott ABA-100.
Heick HM; Bégin-Heick N; Acharya C; Mohammed A
Clin Biochem; 1980 Apr; 13(2):81-3. PubMed ID: 7389075
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of the analytical variability of urine protein-to-creatinine ratio in cats.
Giraldi M; Rossi G; Bertazzolo W; Negri S; Paltrinieri S; Scarpa P
Vet Clin Pathol; 2018 Sep; 47(3):448-457. PubMed ID: 30134504
[TBL] [Abstract][Full Text] [Related]
17. Development and evaluation of an automated dye-binding assay for protein in cerebrospinal fluid.
Huang CM
Clin Chem; 1988 May; 34(5):980-3. PubMed ID: 3370801
[TBL] [Abstract][Full Text] [Related]
18. An automated turbidimetric method for fibrinogen determination in dogs.
Tecles F; Tvarijonaviciute A; Caldín M; Martínez-Subiela S; Cerón JJ
Vet Clin Pathol; 2014 Jun; 43(2):172-9. PubMed ID: 24588657
[TBL] [Abstract][Full Text] [Related]
19. The quantitation and fractionation of proteins in cerebrospinal fluid.
Wise BL
Am J Med Technol; 1982 Oct; 48(10):821-7. PubMed ID: 6817634
[TBL] [Abstract][Full Text] [Related]
20. [Turbidimetric protein determination with benzethonium chloride and sulfosalicylic acid].
Lehmitz R
Z Med Lab Diagn; 1986; 27(2):89-91. PubMed ID: 3705706
[No Abstract] [Full Text] [Related]
[Next] [New Search]