These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

242 related articles for article (PubMed ID: 24485735)

  • 21. Comparison of debonding characteristics of metal and ceramic orthodontic brackets to enamel: an in-vitro study.
    Habibi M; Nik TH; Hooshmand T
    Am J Orthod Dentofacial Orthop; 2007 Nov; 132(5):675-9. PubMed ID: 18005843
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Metal and ceramic bracket effects on human buccal mucosa epithelial cells.
    Pereira BR; Tanaka OM; Lima AA; Guariza-Filho O; Maruo H; Camargo ES
    Angle Orthod; 2009 Mar; 79(2):373-9. PubMed ID: 19216594
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Frictional evaluation of silica-coated ceramic brackets.
    Pisklak CW; Salas A; English JD; Powers JM
    Tex Dent J; 2005 Feb; 122(2):146-8. PubMed ID: 15822374
    [No Abstract]   [Full Text] [Related]  

  • 24. Are social judgements made by children in relation to orthodontic appliances?
    Patel A; Rodd HD; Baker SR; Marshman Z; Robinson PG; Benson PE
    J Orthod; 2010 Jun; 37(2):93-9. PubMed ID: 20567032
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Impact of wearing fixed orthodontic appliances on oral health-related quality of life among Brazilian children.
    Costa Aa; Ferreira MC; Serra-Negra JM; Pordeus IA; Paiva SM
    J Orthod; 2011 Dec; 38(4):275-81. PubMed ID: 22156183
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparative evaluation of frictional forces in active and passive self-ligating brackets with various archwire alloys.
    Krishnan M; Kalathil S; Abraham KM
    Am J Orthod Dentofacial Orthop; 2009 Nov; 136(5):675-82. PubMed ID: 19892284
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Galvanic corrosion behavior of orthodontic archwire alloys coupled to bracket alloys.
    Iijima M; Endo K; Yuasa T; Ohno H; Hayashi K; Kakizaki M; Mizoguchi I
    Angle Orthod; 2006 Jul; 76(4):705-11. PubMed ID: 16808581
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Enamel demineralization with two forms of archwire ligation investigated using an in situ caries model--a pilot study.
    Gameiro GH; Nouer DF; Cenci MS; Cury JA
    Eur J Orthod; 2009 Oct; 31(5):542-6. PubMed ID: 19342424
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Advances in fixed appliance design and use: 2. Auxiliaries, adhesives, appliance care and debonding.
    Postlethwaite KM
    Dent Update; 1992 Oct; 19(8):331-5. PubMed ID: 1291382
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effect of light-cured filled sealant on shear bond strength of metal and ceramic brackets bonded with a resin-modified glass ionomer cement.
    Varlik SK; Ulusoy C
    Am J Orthod Dentofacial Orthop; 2009 Feb; 135(2):194-8. PubMed ID: 19201326
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Three-dimensional ultrashort echo magnetic resonance imaging of orthodontic appliances in the natural dentition.
    Cox RJ; Kau CH; Rasche V
    Am J Orthod Dentofacial Orthop; 2012 Oct; 142(4):552-61. PubMed ID: 22999679
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Bond strengths and debonding characteristics of two types of polycrystalline ceramic brackets.
    Lemke K; Xu X; Hagan JL; Armbruster PC; Ballard RW
    Aust Orthod J; 2010 Nov; 26(2):134-40. PubMed ID: 21175022
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Evaluation of frictional forces of polycarbonate self-ligating brackets.
    Fernandes DJ; Miguel JA; Quintão CC; Elias CN
    World J Orthod; 2010; 11(3):250-5. PubMed ID: 20877734
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of frictional forces during dental alignment: an experimental model with 3 nonleveled brackets.
    Matarese G; Nucera R; Militi A; Mazza M; Portelli M; Festa F; Cordasco G
    Am J Orthod Dentofacial Orthop; 2008 May; 133(5):708-15. PubMed ID: 18456144
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Frictional resistances of different bracket-wire combinations.
    Kapur Wadhwa R; Kwon HK; Close JM
    Aust Orthod J; 2004 May; 20(1):25-30. PubMed ID: 15233584
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Mandibular dental arch changes associated with treatment of crowding using self-ligating and conventional brackets.
    Pandis N; Polychronopoulou A; Makou M; Eliades T
    Eur J Orthod; 2010 Jun; 32(3):248-53. PubMed ID: 19959610
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A modified thermoplastic retainer.
    Pithon MM
    Prog Orthod; 2012 Sep; 13(2):195-9. PubMed ID: 23021123
    [TBL] [Abstract][Full Text] [Related]  

  • 38. In vitro frictional forces generated by three different ligation methods.
    Gandini P; Orsi L; Bertoncini C; Massironi S; Franchi L
    Angle Orthod; 2008 Sep; 78(5):917-21. PubMed ID: 18298218
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Influence of orthodontic treatment on adolescents' self-perceptions of esthetics.
    Feu D; Oliveira BH; Celeste RK; Miguel JA
    Am J Orthod Dentofacial Orthop; 2012 Jun; 141(6):743-50. PubMed ID: 22640676
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Nonlinear large-deflection analysis of orthodontic wires.
    Hayashi K; Araki Y; Mizoguchi I
    Angle Orthod; 2004 Feb; 74(1):112-7. PubMed ID: 15038499
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.