These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

203 related articles for article (PubMed ID: 24488448)

  • 21. Precision of Ci-navigated extension and flexion gap balancing in total knee arthroplasty and analysis of potential predictive variables.
    Fickert S; Jawhar A; Sunil P; Scharf HP
    Arch Orthop Trauma Surg; 2012 Apr; 132(4):565-74. PubMed ID: 22072193
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Computer-assisted surgery in total knee replacement. Preliminary results: report of 60 cases].
    El Masri F; Rammal H; Ghanem I; El Hage S; El Abiad R; Kharrat K; Dagher F
    Rev Chir Orthop Reparatrice Appar Mot; 2008 May; 94(3):261-7. PubMed ID: 18456061
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Measuring long radiographs affects the positioning of femoral components in total knee arthroplasty: a randomized controlled trial.
    Stucinskas J; Robertsson O; Lebedev A; Wingstrand H; Smailys A; Tarasevicius S
    Arch Orthop Trauma Surg; 2016 May; 136(5):693-700. PubMed ID: 26971267
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation.
    Matziolis G; Krocker D; Weiss U; Tohtz S; Perka C
    J Bone Joint Surg Am; 2007 Feb; 89(2):236-43. PubMed ID: 17272435
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Preoperative Measurement of Tibial Resection in Total Knee Arthroplasty Improves Accuracy of Postoperative Limb Alignment Restoration.
    Wu PH; Zhang ZQ; Fang SY; Yang ZB; Kang Y; Fu M; Liao WM
    Chin Med J (Engl); 2016 Nov; 129(21):2524-2529. PubMed ID: 27779156
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of individual distal femoral valgus resection in total knee arthroplasty for patients with valgus knee: A retrospective cohort study.
    Zhou K; Zhou Z; Shi X; Shen B; Kang P; Yang J; Pei F
    Int J Surg; 2018 Apr; 52():309-313. PubMed ID: 29535013
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Improved femoral component rotation in advanced genu valgum deformity using computer-assisted measured resection total knee arthroplasty.
    Lin SJ; Lee CY; Huang KC; Peng KT; Huang TW; Lee MS; Hsu RW; Shen WJ
    J Orthop Surg Res; 2015 Sep; 10():135. PubMed ID: 26328925
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Fixed Distal Femoral Cut of 6° Valgus in Total Knee Arthroplasty: A Radiographic Review of 788 Consecutive Cases.
    Andrews SN; Beeler DM; Parke EA; Nakasone CK; Stickley CD
    J Arthroplasty; 2019 Apr; 34(4):755-759. PubMed ID: 30616977
    [TBL] [Abstract][Full Text] [Related]  

  • 29. How to accurately determine the distal femoral valgus cut angle in the valgus knee arthroplasty.
    Tan H; Wang Y; Long T; Nie B; Mao Z; Yue B
    Int Orthop; 2018 Mar; 42(3):537-542. PubMed ID: 29356933
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Defining distal femoral anatomy for rotational alignment in total knee arthroplasty: a magnetic resonance imaging-based study.
    Amaranath JE; Moopanar TR; Sorial RM
    ANZ J Surg; 2014 Nov; 84(11):852-5. PubMed ID: 24902722
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Postoperative alignment of TKA in patients with severe preoperative varus or valgus deformity: is there a difference between surgical techniques?
    Rahm S; Camenzind RS; Hingsammer A; Lenz C; Bauer DE; Farshad M; Fucentese SF
    BMC Musculoskelet Disord; 2017 Jun; 18(1):272. PubMed ID: 28637433
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison of total knee arthroplasty using computer-assisted navigation versus conventional guiding systems: a prospective study.
    Pang CH; Chan WL; Yen CH; Cheng SC; Woo SB; Choi ST; Hui WK; Mak KH
    J Orthop Surg (Hong Kong); 2009 Aug; 17(2):170-3. PubMed ID: 19721145
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Improving tibial component coronal alignment during total knee arthroplasty with use of a tibial planing device.
    Patil S; D'Lima DD; Fait JM; Colwell CW
    J Bone Joint Surg Am; 2007 Feb; 89(2):381-7. PubMed ID: 17272454
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparison with Navigation of a Novel Three-Step Technique for Improving Accuracy of the Distal Femoral Resection during Conventional TKA: A Case-Control Study.
    Mullaji AB; Khalifa AA; Shetty G; Thakur H
    J Knee Surg; 2023 Jan; 36(2):195-200. PubMed ID: 34237781
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Total knee arthroplasty after varus osteotomy of the distal part of the femur.
    Nelson CL; Saleh KJ; Kassim RA; Windsor R; Haas S; Laskin R; Sculco T
    J Bone Joint Surg Am; 2003 Jun; 85(6):1062-5. PubMed ID: 12784003
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Preoperative malalignment increases risk of failure after total knee arthroplasty.
    Ritter MA; Davis KE; Davis P; Farris A; Malinzak RA; Berend ME; Meding JB
    J Bone Joint Surg Am; 2013 Jan; 95(2):126-31. PubMed ID: 23324959
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Computer-assisted techniques versus conventional guides for component alignment in total knee arthroplasty: a randomized controlled trial.
    Blakeney WG; Khan RJ; Wall SJ
    J Bone Joint Surg Am; 2011 Aug; 93(15):1377-84. PubMed ID: 21915542
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Accuracy of A Handheld Accelerometer-Based Navigation System for Femoral and Tibial Resection in Total Knee Arthroplasty.
    Huang EH; Copp SN; Bugbee WD
    J Arthroplasty; 2015 Nov; 30(11):1906-10. PubMed ID: 26165954
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Preliminary radiological evaluation of the Vector Vision CT-free knee module for implantation of the LCS knee prosthesis.
    Malik MH; Wadia F; Porter ML
    Knee; 2007 Jan; 14(1):19-21. PubMed ID: 17161605
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Tibial component alignment after total knee arthroplasty with intramedullary instrumentation: a prospective analysis.
    Talmo CT; Cooper AJ; Wuerz T; Lang JE; Bono JV
    J Arthroplasty; 2010 Dec; 25(8):1209-15. PubMed ID: 19879723
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.