BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 24491230)

  • 1. Optimization of tomotherapy treatment planning for patients with bilateral hip prostheses.
    Chapman D; Smith S; Barnett R; Bauman G; Yartsev S
    Radiat Oncol; 2014 Feb; 9():43. PubMed ID: 24491230
    [TBL] [Abstract][Full Text] [Related]  

  • 2. KVCT, MVCT, and hybrid CT image studies--treatment planning and dose delivery equivalence on helical tomotherapy.
    Martin S; Yartsev S
    Med Phys; 2010 Jun; 37(6):2847-54. PubMed ID: 20632596
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prostate cancer: contouring target and organs at risk by kilovoltage and megavoltage CT and MRI in patients with and without hip prostheses.
    Falcinelli L; Palumbo I; Radicchia V; Arcidiacono F; Lancellotta V; Montesi G; Matrone F; Zucchetti C; Marcantonini M; Bini V; Aristei C
    Br J Radiol; 2015; 88(1056):20150509. PubMed ID: 26462970
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical evaluation of normalized metal artifact reduction in kVCT using MVCT prior images (MVCT-NMAR) for radiation therapy treatment planning.
    Paudel MR; Mackenzie M; Fallone BG; Rathee S
    Int J Radiat Oncol Biol Phys; 2014 Jul; 89(3):682-9. PubMed ID: 24751408
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Can megavoltage computed tomography reduce proton range uncertainties in treatment plans for patients with large metal implants?
    Newhauser WD; Giebeler A; Langen KM; Mirkovic D; Mohan R
    Phys Med Biol; 2008 May; 53(9):2327-44. PubMed ID: 18421122
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning.
    Paudel MR; Mackenzie M; Fallone BG; Rathee S
    Med Phys; 2013 Aug; 40(8):081701. PubMed ID: 23927298
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The use of megavoltage CT (MVCT) images for dose recomputations.
    Langen KM; Meeks SL; Poole DO; Wagner TH; Willoughby TR; Kupelian PA; Ruchala KJ; Haimerl J; Olivera GH
    Phys Med Biol; 2005 Sep; 50(18):4259-76. PubMed ID: 16148392
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluating on-board kVCT- and MVCT-based dose calculation accuracy using a thorax phantom for helical tomotherapy treatments.
    Tegtmeier RC; Ferris WS; Chen R; Miller JR; Bayouth JE; Culberson WS
    Biomed Phys Eng Express; 2023 Feb; 9(2):. PubMed ID: 36745904
    [No Abstract]   [Full Text] [Related]  

  • 9. Assessing prostate, bladder and rectal doses during image guided radiation therapy--need for plan adaptation?
    Varadhan R; Hui SK; Way S; Nisi K
    J Appl Clin Med Phys; 2009 Jul; 10(3):56-74. PubMed ID: 19692971
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-dose-rate prostate brachytherapy in a patient with bilateral hip prostheses planned using megavoltage computed tomography images acquired with a helical tomotherapy unit.
    Holly R; Myrehaug S; Kamran A; Sankreacha R; Morton G
    Brachytherapy; 2009; 8(1):70-3. PubMed ID: 19041281
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Real patient data based cross verification of kilovoltage and megavoltage CT calibration for proton therapy.
    Nishioka S; Park JH; Zou W; Zhang M; Yue NJ; Chen T
    Phys Med; 2016 Feb; 32(2):343-52. PubMed ID: 26924472
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Initial experience with megavoltage (MV) CT guidance for daily prostate alignments.
    Langen KM; Zhang Y; Andrews RD; Hurley ME; Meeks SL; Poole DO; Willoughby TR; Kupelian PA
    Int J Radiat Oncol Biol Phys; 2005 Aug; 62(5):1517-24. PubMed ID: 16029814
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of different air CT numbers for IVDT on the dose distribution in TomoTherapy MVCT.
    Tsunemine S; Ozawa S; Nakao M; Miura H; Saito A; Kawahara D; Onishi Y; Onishi T; Hashiguchi T; Matsumoto Y; Maruta T; Murakami Y; Nagata Y
    J Appl Clin Med Phys; 2023 Feb; 24(2):e13835. PubMed ID: 36316723
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Deformable registration of the planning image (kVCT) and the daily images (MVCT) for adaptive radiation therapy.
    Lu W; Olivera GH; Chen Q; Ruchala KJ; Haimerl J; Meeks SL; Langen KM; Kupelian PA
    Phys Med Biol; 2006 Sep; 51(17):4357-74. PubMed ID: 16912386
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of image value-to-density table (IVDT) on the accuracy of delivery quality assurance (DQA) process in helical tomotherapy.
    Song JY; Ahn SJ
    Med Dosim; 2012; 37(3):265-70. PubMed ID: 22189030
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Three-dimensional image-based planning for cervix brachytherapy with bilateral hip prostheses: a solution using MVCT with helical tomotherapy.
    Korol RM; Surry K; Davidson MT; Yartsev S; Rodrigues G; D'Souza DP
    Brachytherapy; 2010; 9(3):278-81. PubMed ID: 20189887
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Radiobiological and dosimetric analysis of daily megavoltage CT registration on adaptive radiotherapy with Helical Tomotherapy.
    Mavroidis P; Su FC; Giantsoudi D; Stathakis S; Komisopoulos G; Shi C; Swanson G; Papanikolaou N
    Technol Cancer Res Treat; 2011 Feb; 10(1):1-13. PubMed ID: 21214283
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparing Efficacy Between Robust and PTV Margin-based Optimizations for Interfractional Anatomical Variations in Prostate Tomotherapy.
    Yagihashi T; Inoue T; Shiba S; Yamano A; Yamanaka M; Sato N; Inoue K; Omura M; Nagata H
    In Vivo; 2024; 38(1):409-417. PubMed ID: 38148099
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical implementation of kVCT-guided tomotherapy with ClearRT.
    Yang B; Geng H; Chang TYA; Tse MY; Lam WW; Huang CY; Wu T; Lau KK; Cheung KY; Chiu G; Yu SK
    Phys Eng Sci Med; 2022 Sep; 45(3):915-924. PubMed ID: 35925545
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Consistency check of planned adaptive option on helical tomotherapy.
    Schirm M; Yartsev S; Bauman G; Battista J; Van Dyk J
    Technol Cancer Res Treat; 2008 Dec; 7(6):425-32. PubMed ID: 19044321
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.