These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

92 related articles for article (PubMed ID: 24492411)

  • 1. Negative electrospray ionization on porous supporting tips for mass spectrometric analysis: electrostatic charging effect on detection sensitivity and its application to explosive detection.
    Wong MY; Man SH; Che CM; Lau KC; Ng KM
    Analyst; 2014 Mar; 139(6):1482-91. PubMed ID: 24492411
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Electrospray ionization on porous spraying tips for direct sample analysis by mass spectrometry: enhanced detection sensitivity and selectivity using hydrophobic/hydrophilic materials as spraying tips.
    Wong MY; Tang HW; Man SH; Lam CW; Che CM; Ng KM
    Rapid Commun Mass Spectrom; 2013 Mar; 27(6):713-21. PubMed ID: 23418151
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Use of porous graphitic carbon for the analysis of nitrate ester, nitramine and nitroaromatic explosives and by-products by liquid chromatography-atmospheric pressure chemical ionisation-mass spectrometry.
    Tachon R; Pichon V; Le Borgne MB; Minet JJ
    J Chromatogr A; 2007 Jun; 1154(1-2):174-81. PubMed ID: 17451723
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sensitive ionization of non-volatile analytes using protein solutions as spray liquid in desorption electrospray ionization mass spectrometry.
    Zhu Z; Han J; Zhang Y; Zhou Y; Xu N; Zhang B; Gu H; Chen H
    Rapid Commun Mass Spectrom; 2012 Dec; 26(23):2770-6. PubMed ID: 23124668
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Metal cation detection in positive ion mode electrospray ionization mass spectrometry using a tetracationic salt as a gas-phase ion-pairing agent: evaluation of the effect of chelating agents on detection sensitivity.
    Xu C; Dodbiba E; Padivitage NL; Breitbach ZS; Armstrong DW
    Rapid Commun Mass Spectrom; 2012 Dec; 26(24):2885-96. PubMed ID: 23136019
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sensitive analysis of metal cations in positive ion mode electrospray ionization mass spectrometry using commercial chelating agents and cationic ion-pairing reagents.
    Dodbiba E; Xu C; Wanigasekara E; Armstrong DW
    Rapid Commun Mass Spectrom; 2012 May; 26(9):1005-13. PubMed ID: 22467449
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Role of opposite charges in protein electrospray ionization mass spectrometry.
    Samalikova M; Grandori R
    J Mass Spectrom; 2003 Sep; 38(9):941-7. PubMed ID: 14505321
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Liquid chromatography/electrospray ionization tandem mass spectrometry analysis of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX).
    Pan X; Zhang B; Tian K; Jones LE; Liu J; Anderson TA; Wang JS; Cobb GP
    Rapid Commun Mass Spectrom; 2006; 20(14):2222-6. PubMed ID: 16791873
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Study of the electrical connection mechanism of sheathless interface for capillary electrophoresis-electrospray ionization-mass spectrometry.
    Tie C; Zhang DW; Chen HX; Song SL; Zhang XX
    J Mass Spectrom; 2012 Nov; 47(11):1429-34. PubMed ID: 23147818
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Desorption electro-flow focusing ionization of explosives and narcotics for ambient pressure mass spectrometry.
    Forbes TP; Brewer TM; Gillen G
    Analyst; 2013 Oct; 138(19):5665-73. PubMed ID: 23923127
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fragmentation study of hexanitrostilbene by ion trap multiple mass spectrometry and analysis by liquid chromatography/mass spectrometry.
    Fu X; Zhang Y; Shi S; Gao F; Wen D; Li W; Liao Y; Liu H
    Rapid Commun Mass Spectrom; 2006; 20(19):2906-14. PubMed ID: 16941723
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The relative influences of acidity and polarity on responsiveness of small organic molecules to analysis with negative ion electrospray ionization mass spectrometry (ESI-MS).
    Henriksen T; Juhler RK; Svensmark B; Cech NB
    J Am Soc Mass Spectrom; 2005 Apr; 16(4):446-55. PubMed ID: 15792713
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ambient diode laser desorption dielectric barrier discharge ionization mass spectrometry of nonvolatile chemicals.
    Gilbert-López B; Schilling M; Ahlmann N; Michels A; Hayen H; Molina-Díaz A; García-Reyes JF; Franzke J
    Anal Chem; 2013 Mar; 85(6):3174-82. PubMed ID: 23419061
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Detection of the improvised explosives ammonium nitrate (AN) and urea nitrate (UN) using non-aqueous solvents with electrospray ionization and MS/MS detection.
    Corbin I; McCord B
    Talanta; 2013 Oct; 115():533-9. PubMed ID: 24054629
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Direct analysis of large living organism by megavolt electrostatic ionization mass spectrometry.
    Ng KM; Tang HW; Man SH; Mak PY; Choi YC; Wong MY
    J Am Soc Mass Spectrom; 2014 Sep; 25(9):1515-20. PubMed ID: 24924518
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The analysis of high explosives by liquid chromatography/electrospray ionization mass spectrometry: multiplexed detection of negative ion adducts.
    Mathis JA; McCord BR
    Rapid Commun Mass Spectrom; 2005; 19(2):99-104. PubMed ID: 15584084
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Highly sensitive screening method for nitroaromatic, nitramine and nitrate ester explosives by high performance liquid chromatography-atmospheric pressure ionization-mass spectrometry (HPLC-API-MS) in forensic applications.
    Xu X; van de Craats AM; de Bruyn PC
    J Forensic Sci; 2004 Nov; 49(6):1171-80. PubMed ID: 15568687
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ambient ionization mass spectrometry: a tutorial.
    Huang MZ; Cheng SC; Cho YT; Shiea J
    Anal Chim Acta; 2011 Sep; 702(1):1-15. PubMed ID: 21819855
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Detection of explosives on skin using ambient ionization mass spectrometry.
    Justes DR; Talaty N; Cotte-Rodriguez I; Cooks RG
    Chem Commun (Camb); 2007 Jun; (21):2142-4. PubMed ID: 17520116
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Investigation of the ionisation and fragmentation behaviour of different nitroaromatic compounds occurring as polar metabolites of explosives using electrospray ionisation tandem mass spectrometry.
    Schmidt AC; Herzschuh R; Matysik FM; Engewald W
    Rapid Commun Mass Spectrom; 2006; 20(15):2293-302. PubMed ID: 16810704
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.