These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

99 related articles for article (PubMed ID: 24505755)

  • 1. Improved myocardial scar characterization by super-resolution reconstruction in late gadolinium enhanced MRI.
    Dzyubachyk O; Tao Q; Poot DH; Lamb H; Zeppenfeld K; Lelieveldt BP; van der Geest RJ
    Med Image Comput Comput Assist Interv; 2013; 16(Pt 3):147-54. PubMed ID: 24505755
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Super-resolution reconstruction of late gadolinium-enhanced MRI for improved myocardial scar assessment.
    Dzyubachyk O; Tao Q; Poot DH; Lamb HJ; Zeppenfeld K; Lelieveldt BP; van der Geest RJ
    J Magn Reson Imaging; 2015 Jul; 42(1):160-7. PubMed ID: 25236764
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Automated left ventricle segmentation in late gadolinium-enhanced MRI for objective myocardial scar assessment.
    Tao Q; Piers SR; Lamb HJ; van der Geest RJ
    J Magn Reson Imaging; 2015 Aug; 42(2):390-9. PubMed ID: 25408195
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Volumetric late gadolinium-enhanced myocardial imaging with retrospective inversion time selection.
    Kecskemeti S; Johnson K; François CJ; Schiebler ML; Unal O
    J Magn Reson Imaging; 2013 Nov; 38(5):1276-82. PubMed ID: 23389851
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rapid single-breath-hold 3D late gadolinium enhancement cardiac MRI using a stack-of-spirals acquisition.
    Shin T; Lustig M; Nishimura DG; Hu BS
    J Magn Reson Imaging; 2014 Dec; 40(6):1496-502. PubMed ID: 24243575
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Free breathing three-dimensional late gadolinium enhancement cardiovascular magnetic resonance using outer volume suppressed projection navigators.
    Menon RG; Miller GW; Jeudy J; Rajagopalan S; Shin T
    Magn Reson Med; 2017 Apr; 77(4):1533-1543. PubMed ID: 27122450
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Whole-heart 3D late gadolinium-enhanced MR imaging: investigation of optimal scan parameters and clinical usefulness.
    Yorimitsu M; Yokoyama K; Nitatori T; Yoshino H; Isono S; Kuhara S
    Magn Reson Med Sci; 2012; 11(1):9-16. PubMed ID: 22450382
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Differences in quantitative assessment of myocardial scar and gray zone by LGE-CMR imaging using established gray zone protocols.
    Mesubi O; Ego-Osuala K; Jeudy J; Purtilo J; Synowski S; Abutaleb A; Niekoop M; Abdulghani M; Asoglu R; See V; Saliaris A; Shorofsky S; Dickfeld T
    Int J Cardiovasc Imaging; 2015 Feb; 31(2):359-68. PubMed ID: 25352244
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Improved multimodality data fusion of late gadolinium enhancement MRI to left ventricular voltage maps in ventricular tachycardia ablation.
    Roujol S; Basha TA; Tan A; Khanna V; Chan RH; Moghari MH; Rayatzadeh H; Shaw JL; Josephson ME; Nezafat R
    IEEE Trans Biomed Eng; 2013 May; 60(5):1308-17. PubMed ID: 23247842
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An improved real-time cine Late Gadolinium Enhancement (LGE) imaging method at 3T.
    Kadbi M; Kotys M; Alshaher M; Fischer S; Amini AA
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():531-4. PubMed ID: 22254365
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Gray blood late gadolinium enhancement cardiovascular magnetic resonance for improved detection of myocardial scar.
    Fahmy AS; Neisius U; Tsao CW; Berg S; Goddu E; Pierce P; Basha TA; Ngo L; Manning WJ; Nezafat R
    J Cardiovasc Magn Reson; 2018 Mar; 20(1):22. PubMed ID: 29562921
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Automated segmentation of myocardial scar in late enhancement MRI using combined intensity and spatial information.
    Tao Q; Milles J; Zeppenfeld K; Lamb HJ; Bax JJ; Reiber JH; van der Geest RJ
    Magn Reson Med; 2010 Aug; 64(2):586-94. PubMed ID: 20665801
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Improved border sharpness of post-infarct scar by a novel self-navigated free-breathing high-resolution 3D whole-heart inversion recovery magnetic resonance approach.
    Rutz T; Piccini D; Coppo S; Chaptinel J; Ginami G; Vincenti G; Stuber M; Schwitter J
    Int J Cardiovasc Imaging; 2016 Dec; 32(12):1735-1744. PubMed ID: 27549804
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Myocardial infarct segmentation and reconstruction from 2D late-gadolinium enhanced magnetic resonance images.
    Ukwatta E; Yuan J; Qiu W; Wu KC; Trayanova N; Vadakkumpadan F
    Med Image Comput Comput Assist Interv; 2014; 17(Pt 2):554-61. PubMed ID: 25485423
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Artificial Intelligence for Contrast-Free MRI: Scar Assessment in Myocardial Infarction Using Deep Learning-Based Virtual Native Enhancement.
    Zhang Q; Burrage MK; Shanmuganathan M; Gonzales RA; Lukaschuk E; Thomas KE; Mills R; Leal Pelado J; Nikolaidou C; Popescu IA; Lee YP; Zhang X; Dharmakumar R; Myerson SG; Rider O; ; Channon KM; Neubauer S; Piechnik SK; Ferreira VM
    Circulation; 2022 Nov; 146(20):1492-1503. PubMed ID: 36124774
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fully automatic segmentation of left atrium and pulmonary veins in late gadolinium-enhanced MRI: Towards objective atrial scar assessment.
    Tao Q; Ipek EG; Shahzad R; Berendsen FF; Nazarian S; van der Geest RJ
    J Magn Reson Imaging; 2016 Aug; 44(2):346-54. PubMed ID: 26752729
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Diagnostic accuracy of late iodine-enhancement dual-energy computed tomography for the detection of chronic myocardial infarction compared with late gadolinium-enhancement 3-T magnetic resonance imaging.
    Wichmann JL; Bauer RW; Doss M; Stock W; Lehnert T; Bodelle B; Frellesen C; Vogl TJ; Kerl JM
    Invest Radiol; 2013 Dec; 48(12):851-6. PubMed ID: 23907104
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improvement of late gadolinium enhancement image quality using a deep learning-based reconstruction algorithm and its influence on myocardial scar quantification.
    van der Velde N; Hassing HC; Bakker BJ; Wielopolski PA; Lebel RM; Janich MA; Kardys I; Budde RPJ; Hirsch A
    Eur Radiol; 2021 Jun; 31(6):3846-3855. PubMed ID: 33219845
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of semi-automated scar quantification techniques using high-resolution, 3-dimensional late-gadolinium-enhancement magnetic resonance imaging.
    Rajchl M; Stirrat J; Goubran M; Yu J; Scholl D; Peters TM; White JA
    Int J Cardiovasc Imaging; 2015 Feb; 31(2):349-57. PubMed ID: 25307896
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical evaluation of three-dimensional late enhancement MRI.
    Bratis K; Henningsson M; Grigoratos C; Omodarme MD; Chasapides K; Botnar R; Nagel E
    J Magn Reson Imaging; 2017 Jun; 45(6):1675-1683. PubMed ID: 27801994
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.