BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

253 related articles for article (PubMed ID: 24506606)

  • 1. Establishing a process of irradiating small animal brain using a CyberKnife and a microCT scanner.
    Kim H; Fabien J; Zheng Y; Yuan J; Brindle J; Sloan A; Yao M; Lo S; Wessels B; Machtay M; Welford S; Sohn JW
    Med Phys; 2014 Feb; 41(2):021715. PubMed ID: 24506606
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters.
    Bache ST; Juang T; Belley MD; Koontz BF; Adamovics J; Yoshizumi TT; Kirsch DG; Oldham M
    Med Phys; 2015 Feb; 42(2):846-55. PubMed ID: 25652497
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The development and testing of a novel spherical radiotherapy phantom system for the commissioning and patient-specific quality assurance of mono-isocentric multiple mets SRS plans.
    McKenna JT
    Med Phys; 2021 Jan; 48(1):105-113. PubMed ID: 33119902
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A 3D printed modular phantom for quality assurance of image-guided small animal irradiators: Design, imaging experiments, and Monte Carlo simulations.
    Breitkreutz DY; Bialek S; Vojnovic B; Kavanagh A; Johnstone CD; Rovner Z; Tsouchlos P; Kanesalingam T; Bazalova-Carter M
    Med Phys; 2019 May; 46(5):2015-2024. PubMed ID: 30947359
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A method for generating intensity-modulated radiation therapy fields for small animal irradiators utilizing 3D-printed compensator molds.
    Yoon SW; Kodra J; Miles DA; Kirsch DG; Oldham M
    Med Phys; 2020 Sep; 47(9):4363-4371. PubMed ID: 32281657
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance evaluation of a CyberKnife G4 image-guided robotic stereotactic radiosurgery system.
    Antypas C; Pantelis E
    Phys Med Biol; 2008 Sep; 53(17):4697-718. PubMed ID: 18695294
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of tracking accuracy of the CyberKnife system using a webcam and printed calibrated grid.
    Sumida I; Shiomi H; Higashinaka N; Murashima Y; Miyamoto Y; Yamazaki H; Mabuchi N; Tsuda E; Ogawa K
    J Appl Clin Med Phys; 2016 Mar; 17(2):74-84. PubMed ID: 27074474
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Experimental evaluations of the accuracy of 3D and 4D planning in robotic tracking stereotactic body radiotherapy for lung cancers.
    Chan MK; Kwong DL; Ng SC; Tong AS; Tam EK
    Med Phys; 2013 Apr; 40(4):041712. PubMed ID: 23556882
    [TBL] [Abstract][Full Text] [Related]  

  • 9. On the total system error of a robotic radiosurgery system: phantom measurements, clinical evaluation and long-term analysis.
    Pantelis E; Moutsatsos A; Antypas C; Zoros E; Pantelakos P; Lekas L; Romanelli P; Zourari K; Hourdakis CJ
    Phys Med Biol; 2018 Aug; 63(16):165015. PubMed ID: 30033940
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dosimetric comparison of flattened and unflattened beams for stereotactic ablative radiotherapy of stage I non-small cell lung cancer.
    Hrbacek J; Lang S; Graydon SN; Klöck S; Riesterer O
    Med Phys; 2014 Mar; 41(3):031709. PubMed ID: 24593713
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Characterization of 3D printing techniques: Toward patient specific quality assurance spine-shaped phantom for stereotactic body radiation therapy.
    Kim MJ; Lee SR; Lee MY; Sohn JW; Yun HG; Choi JY; Jeon SW; Suh TS
    PLoS One; 2017; 12(5):e0176227. PubMed ID: 28472175
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Preclinical dose verification using a 3D printed mouse phantom for radiobiology experiments.
    Esplen N; Therriault-Proulx F; Beaulieu L; Bazalova-Carter M
    Med Phys; 2019 Nov; 46(11):5294-5303. PubMed ID: 31461781
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Single-fraction spine SBRT end-to-end testing on TomoTherapy, Vero, TrueBeam, and CyberKnife treatment platforms using a novel anthropomorphic phantom.
    Gallo JJ; Kaufman I; Powell R; Pandya S; Somnay A; Bossenberger T; Ramirez E; Reynolds R; Solberg T; Burmeister J
    J Appl Clin Med Phys; 2015 Jan; 16(1):5120. PubMed ID: 25679169
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development and Validation of a Small Animal Immobilizer and Positioning System for the Study of Delivery of Intracranial and Extracranial Radiotherapy Using the Gamma Knife System.
    Awan MJ; Dorth J; Mani A; Kim H; Zheng Y; Mislmani M; Welford S; Yuan J; Wessels BW; Lo SS; Letterio J; Machtay M; Sloan A; Sohn JW
    Technol Cancer Res Treat; 2017 Apr; 16(2):203-210. PubMed ID: 27444980
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comprehensive investigation of the accuracy and reproducibility of a multitarget single isocenter VMAT radiosurgery technique.
    Thomas A; Niebanck M; Juang T; Wang Z; Oldham M
    Med Phys; 2013 Dec; 40(12):121725. PubMed ID: 24320511
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biological consequences of MLC calibration errors in IMRT delivery and QA.
    Moiseenko V; Lapointe V; James K; Yin L; Liu M; Pawlicki T
    Med Phys; 2012 Apr; 39(4):1917-24. PubMed ID: 22482613
    [TBL] [Abstract][Full Text] [Related]  

  • 17. End-to-end validation of fiducial tracking accuracy in robotic radiosurgery using MRI-only simulation imaging.
    Singhrao K; Zubair M; Nano T; Scholey JE; Descovich M
    Med Phys; 2024 Jan; 51(1):31-41. PubMed ID: 38055419
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of a novel patient-specific quality assurance phantom for robotic single-isocentre, multiple-target stereotactic radiosurgery, and stereotactic radiotherapy.
    Xu Q; Vinogradskiy Y; Grimm J; Nie W; Dupre P; Chawla AK; Bajaj G; Yang H; LaCouture T; Fan J
    Br J Radiol; 2024 Feb; 97(1155):660-667. PubMed ID: 38401536
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Technical description, phantom accuracy, and clinical feasibility for fiducial-free frameless real-time image-guided spinal radiosurgery.
    Muacevic A; Staehler M; Drexler C; Wowra B; Reiser M; Tonn JC
    J Neurosurg Spine; 2006 Oct; 5(4):303-12. PubMed ID: 17048766
    [TBL] [Abstract][Full Text] [Related]  

  • 20. CyberKnife Xsight versus fiducial-based target-tracking: a novel 3D dosimetric comparison in a dynamic phantom.
    Klein TJ; Gill S; Ebert MA; Grogan G; Smith W; Alkhatib Z; Geraghty J; Scott AJD; Brown A; Rowshanfarzad P
    Radiat Oncol; 2022 Sep; 17(1):154. PubMed ID: 36076249
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.