237 related articles for article (PubMed ID: 24506649)
21. New reconstruction method of magnetoacoustic tomography with magnetic induction.
Zhang Y; Liu G; He W; Xia H; Li Y; Li S; Xu J
Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():3061-4. PubMed ID: 21095734
[TBL] [Abstract][Full Text] [Related]
22. Solving the forward problem of magnetoacoustic tomography with magnetic induction by means of the finite element method.
Li X; Li X; Zhu S; He B
Phys Med Biol; 2009 May; 54(9):2667-82. PubMed ID: 19351978
[TBL] [Abstract][Full Text] [Related]
23. Magnetoacoustic tomography with magnetic induction (MAT-MI) for breast tumor imaging: numerical modeling and simulation.
Zhou L; Li X; Zhu S; He B
Phys Med Biol; 2011 Apr; 56(7):1967-83. PubMed ID: 21364262
[TBL] [Abstract][Full Text] [Related]
24. Image Reconstruction in Magnetoacoustic Tomography With Magnetic Induction With Variable Sound Speeds.
Zhang W; Ma R; Zhang S; Yin T; Liu Z
IEEE Trans Biomed Eng; 2016 Dec; 63(12):2585-2594. PubMed ID: 27576240
[TBL] [Abstract][Full Text] [Related]
25. Conductivity Anisotropy Influence on Acoustic Sources for Magnetoacoustic Tomography With Magnetic Induction.
Yu Z; Dai S; Ma Q; Guo G; Tu J; Zhang D
IEEE Trans Biomed Eng; 2018 Nov; 65(11):2512-2518. PubMed ID: 29993525
[TBL] [Abstract][Full Text] [Related]
26. Investigation on magnetoacoustic signal generation with magnetic induction and its application to electrical conductivity reconstruction.
Ma Q; He B
Phys Med Biol; 2007 Aug; 52(16):5085-99. PubMed ID: 17671355
[TBL] [Abstract][Full Text] [Related]
27. Magneto-Acousto-Electrical Tomography With Magnetic Induction for Conductivity Reconstruction.
Guo L; Liu G; Xia H
IEEE Trans Biomed Eng; 2015 Sep; 62(9):2114-24. PubMed ID: 25532166
[TBL] [Abstract][Full Text] [Related]
28. Acoustic Source Analysis of Magnetoacoustic Tomography With Magnetic Induction for Conductivity Gradual-Varying Tissues.
Wang J; Zhou Y; Sun X; Ma Q; Zhang D
IEEE Trans Biomed Eng; 2016 Apr; 63(4):758-64. PubMed ID: 26292332
[TBL] [Abstract][Full Text] [Related]
29. Imaging biological tissues with electrical conductivity contrast below 1 S m by means of magnetoacoustic tomography with magnetic induction.
Hu G; Li X; He B
Appl Phys Lett; 2010 Sep; 97(10):. PubMed ID: 20938494
[TBL] [Abstract][Full Text] [Related]
30. Reconstruction of conductivity using the dual-loop method with one injection current in MREIT.
Lee TH; Nam HS; Lee MG; Kim YJ; Woo EJ; Kwon OI
Phys Med Biol; 2010 Dec; 55(24):7523-39. PubMed ID: 21098919
[TBL] [Abstract][Full Text] [Related]
31. In Vivo Electrical Conductivity Contrast Imaging in a Mouse Model of Cancer Using High-Frequency Magnetoacoustic Tomography With Magnetic Induction (hfMAT-MI).
Kai Yu ; Qi Shao ; Ashkenazi S; Bischof JC; Bin He
IEEE Trans Med Imaging; 2016 Oct; 35(10):2301-2311. PubMed ID: 27834641
[TBL] [Abstract][Full Text] [Related]
32. [Image reconstruction of conductivity on magnetoacoustic tomography with magnetic induction].
Li J; Yin T; Liu Z; Xu G
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2010 Apr; 27(2):416-20. PubMed ID: 20481330
[TBL] [Abstract][Full Text] [Related]
33. Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction.
Xia R; Li X; He B
Appl Phys Lett; 2007 Aug; 91(8):83903. PubMed ID: 19169372
[TBL] [Abstract][Full Text] [Related]
34. A 3D reconstruction algorithm for magneto-acoustic tomography with magnetic induction based on ultrasound transducer characteristics.
Ma R; Zhou X; Zhang S; Yin T; Liu Z
Phys Med Biol; 2016 Dec; 61(24):8762-8778. PubMed ID: 27893440
[TBL] [Abstract][Full Text] [Related]
35. MREIT experiments with 200 µA injected currents: a feasibility study using two reconstruction algorithms, SMM and harmonic B(Z).
Arpinar VE; Hamamura MJ; Degirmenci E; Muftuler LT
Phys Med Biol; 2012 Jul; 57(13):4245-61. PubMed ID: 22684125
[TBL] [Abstract][Full Text] [Related]
36. Electrical conductivity imaging by magnetic resonance electrical impedance tomography (MREIT).
Oh SH; Han JY; Lee SY; Cho MH; Lee BI; Woo EJ
Magn Reson Med; 2003 Oct; 50(4):875-8. PubMed ID: 14523975
[TBL] [Abstract][Full Text] [Related]
37. A study of forward problem of magnetoacoustic tomography with magnetic induction.
He W; Liu G; Zhang Y; Zeng X
Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():4983-6. PubMed ID: 21096678
[TBL] [Abstract][Full Text] [Related]
38. Multishot echo-planar MREIT for fast imaging of conductivity, current density, and electric field distributions.
Chauhan M; Vidya Shankar R; Ashok Kumar N; Kodibagkar VD; Sadleir R
Magn Reson Med; 2018 Jan; 79(1):71-82. PubMed ID: 28205251
[TBL] [Abstract][Full Text] [Related]
39. Effect of the secondary process on mass point vibration velocity propagation in magneto-acoustic tomography and magneto-acousto-electrical tomography.
Sun Z; Liu G; Guo L; Xia H; Wang X
Technol Health Care; 2016 Apr; 24 Suppl 2():S683-9. PubMed ID: 27177099
[TBL] [Abstract][Full Text] [Related]
40. The effect of electrical anisotropy during magnetoacoustic tomography with magnetic induction.
Brinker K; Roth BJ
IEEE Trans Biomed Eng; 2008 May; 55(5):1637-9. PubMed ID: 18440910
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]