These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
135 related articles for article (PubMed ID: 24509221)
1. Internal fixation of bilateral sacroiliac dislocation with transiliac locked plate: a biomechanical study on pelvic models. Sahin O; Demirörs H; Akgün RC; Tuncay IC Acta Orthop Traumatol Turc; 2013; 47(6):411-6. PubMed ID: 24509221 [TBL] [Abstract][Full Text] [Related]
2. Biomechanical comparison of three kinds of fixation in fracture-dislocation of the sacroiliac joint. Wu T; Su K; Zhang YZ; Yang ZY; Li HJ; Han YT Technol Health Care; 2019; 27(1):89-99. PubMed ID: 30507595 [TBL] [Abstract][Full Text] [Related]
3. Do Transsacral-transiliac Screws Across Uninjured Sacroiliac Joints Affect Pain and Functional Outcomes in Trauma Patients? Heydemann J; Hartline B; Gibson ME; Ambrose CG; Munz JW; Galpin M; Achor TS; Gary JL Clin Orthop Relat Res; 2016 Jun; 474(6):1417-21. PubMed ID: 26472585 [TBL] [Abstract][Full Text] [Related]
4. Biomechanical analysis of fixation for vertically unstable sacroiliac dislocations with iliosacral screws and symphyseal plating. Sagi HC; Ordway NR; DiPasquale T J Orthop Trauma; 2004 Mar; 18(3):138-43. PubMed ID: 15091266 [TBL] [Abstract][Full Text] [Related]
6. [A biomechanical evaluation of the sacroiliac anatomy type bar-plate internal fixation system]. Zheng Q; Bi DW; Shi SY; Fei J; Wei W; Zu G; Wang YF; Wang YJ Zhongguo Gu Shang; 2008 Aug; 21(8):577-80. PubMed ID: 19108366 [TBL] [Abstract][Full Text] [Related]
7. Comparison of sacroiliac screw techniques for unstable sacroiliac joint disruptions: a finite element model analysis. Gonçalves RM; Freitas A; Aragão VAD; Azevedo FER; Lopes NB; Mangueira LJA; da Silva LHP; Pires RE; Giordano V Injury; 2023 Nov; 54 Suppl 6():110783. PubMed ID: 38143127 [TBL] [Abstract][Full Text] [Related]
8. S1 pediculoiliac screw fixation in instabilities of the sacroiliac complex: biomechanical study and report of two cases. Sar C; Kilicoglu O J Orthop Trauma; 2003 Apr; 17(4):262-70. PubMed ID: 12679686 [TBL] [Abstract][Full Text] [Related]
9. Biomechanical evaluation of conventional internal contemporary spinal fixation techniques used for stabilization of complete sacroiliac joint separation: a 3-dimensional unilaterally isolated experimental stiffness study. Korovessis PG; Magnissalis EA; Deligianni D Spine (Phila Pa 1976); 2006 Dec; 31(25):E941-51. PubMed ID: 17139210 [TBL] [Abstract][Full Text] [Related]
10. Biomechanical study of four kinds of percutaneous screw fixation in two types of unilateral sacroiliac joint dislocation: a finite element analysis. Zhang L; Peng Y; Du C; Tang P Injury; 2014 Dec; 45(12):2055-9. PubMed ID: 25457345 [TBL] [Abstract][Full Text] [Related]
12. Reduction and fixation of sacroiliac joint dislocation by the combined use of S1 pedicle screws and the galveston technique. Abumi K; Saita M; Iida T; Kaneda K Spine (Phila Pa 1976); 2000 Aug; 25(15):1977-83. PubMed ID: 10908943 [TBL] [Abstract][Full Text] [Related]
13. Does Posterior Fixation of Partially Unstable Open-Book Pelvic Ring Injuries Decrease Symphyseal Plate Failure? A Biomechanical Study. Metz RM; Bledsoe JG; Moed BR J Orthop Trauma; 2018 Feb; 32 Suppl 1():S18-S24. PubMed ID: 29373447 [TBL] [Abstract][Full Text] [Related]
14. Biomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis. Wu T; Ren X; Cui Y; Cheng X; Peng S; Hou Z; Han Y J Orthop Surg Res; 2018 Jun; 13(1):152. PubMed ID: 29914519 [TBL] [Abstract][Full Text] [Related]
15. [A morphologic evaluation of the sacroiliac joint and plate fixation on a pelvic model using a S1 pedicular screw, transiliosacral screws, and a compression rod for sacroiliac joint injuries]. Esenkaya I Acta Orthop Traumatol Turc; 2002; 36(5):432-41. PubMed ID: 12594352 [TBL] [Abstract][Full Text] [Related]
16. Intra-operative multi-dimensional fluoroscopy of guidepin placement prior to iliosacral screw fixation for posterior pelvic ring injuries and sacroiliac dislocation: an early case series. Shaw JC; Routt MLC; Gary JL Int Orthop; 2017 Oct; 41(10):2171-2177. PubMed ID: 28357493 [TBL] [Abstract][Full Text] [Related]
17. Biomechanical comparison of standard iliosacral screw fixation to transsacral locked screw fixation in a type C zone II pelvic fracture model. Tabaie SA; Bledsoe JG; Moed BR J Orthop Trauma; 2013 Sep; 27(9):521-6. PubMed ID: 23114418 [TBL] [Abstract][Full Text] [Related]
18. [Development of polyaxial locking plate screw system of sacroiliac joint]. Fan W; Xie X; Zhou S; Zhang Y Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Sep; 28(9):1091-5. PubMed ID: 25509772 [TBL] [Abstract][Full Text] [Related]
19. Locked versus standard unlocked plating of the pubic symphysis: a cadaver biomechanical study. Grimshaw CS; Bledsoe JG; Moed BR J Orthop Trauma; 2012 Jul; 26(7):402-6. PubMed ID: 22183199 [TBL] [Abstract][Full Text] [Related]
20. Biomechanical Study of Posterior Pelvic Fixations in Vertically Unstable Sacral Fractures: An Alternative to Triangular Osteosynthesis. Chaiyamongkol W; Kritsaneephaiboon A; Bintachitt P; Suwannaphisit S; Tangtrakulwanich B Asian Spine J; 2018 Dec; 12(6):967-972. PubMed ID: 30322262 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]