BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

440 related articles for article (PubMed ID: 24513364)

  • 1. Tissue quality of eye-bank-prepared precut corneas for Descemet's stripping automated endothelial keratoplasty.
    Nelson BA; Ritenour RJ
    Can J Ophthalmol; 2014 Feb; 49(1):92-5. PubMed ID: 24513364
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of eye bank-prepared posterior lamellar corneal tissue for endothelial keratoplasty.
    Rose L; Briceño CA; Stark WJ; Gloria DG; Jun AS
    Ophthalmology; 2008 Feb; 115(2):279-86. PubMed ID: 17599413
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical outcomes in descemet stripping automated endothelial keratoplasty with internationally shipped precut donor corneas.
    Nakagawa H; Inatomi T; Hieda O; Sotozono C; Yokoi N; Iliakis B; Miller TD; Ulrickson C; Kinoshita S
    Am J Ophthalmol; 2014 Jan; 157(1):50-55.e1. PubMed ID: 24210766
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Risk factors for donor endothelial loss in eye bank-prepared posterior lamellar corneal tissue for descemet stripping automated endothelial keratoplasty.
    Liu YC; Alvarez Paraz CM; Cajucom-Uy HY; Agahari D; Sethuraman S; Tan DT; Mehta JS
    Cornea; 2014 Jul; 33(7):677-82. PubMed ID: 24886998
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Endothelial keratoplasty: the relationship between donor tissue storage time and donor endothelial survival.
    Terry MA; Shamie N; Straiko MD; Friend DJ; Davis-Boozer D
    Ophthalmology; 2011 Jan; 118(1):36-40. PubMed ID: 20723995
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Precut tissue in Descemet's stripping automated endothelial keratoplasty donor characteristics and early postoperative complications.
    Chen ES; Terry MA; Shamie N; Hoar KL; Friend DJ
    Ophthalmology; 2008 Mar; 115(3):497-502. PubMed ID: 18221999
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Precut tissue for Descemet's stripping automated endothelial keratoplasty: vision, astigmatism, and endothelial survival.
    Terry MA; Shamie N; Chen ES; Phillips PM; Hoar KL; Friend DJ
    Ophthalmology; 2009 Feb; 116(2):248-56. PubMed ID: 19091414
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thin lenticule Descemet's stripping automated endothelial keratoplasty: single, slow pass technique.
    Vajpayee RB; Maharana PK; Jain S; Sharma N; Jhanji V
    Clin Exp Ophthalmol; 2014 Jul; 42(5):411-6. PubMed ID: 24224697
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Anterior corneal buttons from DSAEK donor tissue can be stored in optisol GS for later use in tectonic lamellar patch grafting.
    Chu HS; Hsieh MC; Chen YM; Hou YC; Hu FR; Chen WL
    Cornea; 2014 Jun; 33(6):555-8. PubMed ID: 24675374
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Corneal Endothelial Cell Loss 3 Years After Successful Descemet Stripping Automated Endothelial Keratoplasty in the Cornea Preservation Time Study: A Randomized Clinical Trial.
    Lass JH; Benetz BA; Verdier DD; Szczotka-Flynn LB; Ayala AR; Liang W; Aldave AJ; Dunn SP; McCall T; Mian SI; Navarro LC; Patel SV; Pramanik S; Rosenwasser GO; Ross KW; Terry MA; Kollman C; Gal RL; Beck RW;
    JAMA Ophthalmol; 2017 Dec; 135(12):1394-1400. PubMed ID: 29127432
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of the precutting and overseas transportation of corneal grafts for Descemet stripping automated endothelial keratoplasty on donor endothelial cell loss.
    Yamazoe K; Yamazoe K; Shinozaki N; Shimazaki J
    Cornea; 2013 Jun; 32(6):741-4. PubMed ID: 23146934
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Precut cornea for Descemet's stripping endothelial keratoplasty: experience at a single eye bank.
    Mohamed A; Chaurasia S; Chandragiri V; Kandhibanda S; Gunnam S; Garg P
    Int Ophthalmol; 2017 Jun; 37(3):525-529. PubMed ID: 27440188
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of organ cultured precut corneas versus surgeon-cut corneas for Descemet's stripping automated endothelial keratoplasty.
    Ragunathan S; Ivarsen A; Nielsen K; Hjortdal J
    Cell Tissue Bank; 2014 Dec; 15(4):573-8. PubMed ID: 24526412
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Descemet-stripping automated endothelial keratoplasty: effect of anterior lamellar corneal tissue-on/-off storage condition on Descemet-stripping automated endothelial keratoplasty donor tissue.
    Ide T; Yoo SH; Kymionis GD; Goldman JM; Perez VL; O'Brien TP
    Cornea; 2008 Aug; 27(7):754-7. PubMed ID: 18650658
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of Gebauer SLc and Moria CBm Carriazo-Barraquer ALK Microkeratomes for Descemet's Stripping Automated Endothelial Keratoplasty Preparation.
    Fuest M; Salla S; Walter P; Plange N; Kuerten D; Flammersfeld A; Hermel M
    Curr Eye Res; 2016; 41(3):343-9. PubMed ID: 25803780
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ultrathin descemet's stripping automated endothelial keratoplasty with the microkeratome double-pass technique: two-year outcomes.
    Busin M; Madi S; Santorum P; Scorcia V; Beltz J
    Ophthalmology; 2013 Jun; 120(6):1186-94. PubMed ID: 23466268
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Donor, Recipient, and Operative Factors Associated With Increased Endothelial Cell Loss in the Cornea Preservation Time Study.
    Lass JH; Benetz BA; Patel SV; Szczotka-Flynn LB; O'Brien R; Ayala AR; Maguire MG; Daoud YJ; Greiner MA; Hannush SB; Lee WB; Mauger TF; Menegay HJ; Mifflin MD; Raizman MB; Rose-Nussbaumer J; Schultze RL; Schmidt GA; Sugar A; Terry MA; Verdier DD;
    JAMA Ophthalmol; 2019 Feb; 137(2):185-193. PubMed ID: 30422157
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Gebauer SLc Original and Moria One-Use Plus automated microkeratomes for ultrathin Descemet's stripping automated endothelial keratoplasty preparation.
    Fuest M; Salla S; Hermel M; Plum WJ; Rütten S; Plange N; Kuerten D; Schnitzler AC; Walter P
    Acta Ophthalmol; 2016 Dec; 94(8):e731-e737. PubMed ID: 27233757
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Endothelial cell loss after Descemet's stripping endothelial keratoplasty in a large prospective series.
    Terry MA; Chen ES; Shamie N; Hoar KL; Friend DJ
    Ophthalmology; 2008 Mar; 115(3):488-496.e3. PubMed ID: 18164063
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Nomogram to Predict Graft Thickness in Descemet Stripping Automated Endothelial Keratoplasty: An Eye Bank Study.
    Bae SS; Menninga I; Hoshino R; Humphreys C; Chan CC
    Cornea; 2018 Jun; 37(6):687-690. PubMed ID: 29377841
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 22.