These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Combining flat crystals, bent crystals and compound refractive lenses for high-energy X-ray optics. Shastri SD J Synchrotron Radiat; 2004 Mar; 11(Pt 2):150-6. PubMed ID: 14960779 [TBL] [Abstract][Full Text] [Related]
5. D2AM, a beamline with a high-intensity point-focusing fixed-exit monochromator for multiwavelength anomalous diffraction experiments. Ferrer JL; Simon JP; Bérar JF; Caillot B; Fanchon E; Kaïkati O; Arnaud S; Guidotti M; Pirocchi M; Roth M J Synchrotron Radiat; 1998 Nov; 5(Pt 6):1346-56. PubMed ID: 16687847 [TBL] [Abstract][Full Text] [Related]
6. An alternative scheme of angular-dispersion analyzers for high-resolution medium-energy inelastic X-ray scattering. Huang XR J Synchrotron Radiat; 2011 Nov; 18(Pt 6):899-906. PubMed ID: 21997915 [TBL] [Abstract][Full Text] [Related]
7. A cryogenically stabilized meV-monochromator for hard X-rays. Toellner TS; Alatas A; Said A; Shu D; Sturhahn W; Zhao J J Synchrotron Radiat; 2006 Mar; 13(Pt 2):211-5. PubMed ID: 16495621 [TBL] [Abstract][Full Text] [Related]
8. An efficient plane-grating monochromator based on conical diffraction for continuous tuning in the entire soft X-ray range including tender X-rays (2-8 keV). Jark W J Synchrotron Radiat; 2016 Jan; 23(1):187-95. PubMed ID: 26698063 [TBL] [Abstract][Full Text] [Related]
10. High-resolution monochromator using a high-efficiency single-mode x-ray resonator at Laue incidence. Wu YH; Tsai YW; Liu WC; Chih YC; Chang SL Opt Lett; 2017 Jul; 42(13):2575-2578. PubMed ID: 28957288 [TBL] [Abstract][Full Text] [Related]
11. Optical design of the short pulse x-ray imaging and microscopy time-angle correlated diffraction beamline at the Advanced Photon Source. Reininger R; Dufresne EM; Borland M; Beno MA; Young L; Kim KJ; Evans PG Rev Sci Instrum; 2013 May; 84(5):053103. PubMed ID: 23742528 [TBL] [Abstract][Full Text] [Related]
12. KMC-1: a high resolution and high flux soft x-ray beamline at BESSY. Schaefers F; Mertin M; Gorgoi M Rev Sci Instrum; 2007 Dec; 78(12):123102. PubMed ID: 18163715 [TBL] [Abstract][Full Text] [Related]
13. Polarization control of an X-ray free-electron laser with a diamond phase retarder. Suzuki M; Inubushi Y; Yabashi M; Ishikawa T J Synchrotron Radiat; 2014 May; 21(Pt 3):466-72. PubMed ID: 24763633 [TBL] [Abstract][Full Text] [Related]
14. Performance of a beam-multiplexing diamond crystal monochromator at the Linac Coherent Light Source. Zhu D; Feng Y; Stoupin S; Terentyev SA; Lemke HT; Fritz DM; Chollet M; Glownia JM; Alonso-Mori R; Sikorski M; Song S; van Driel TB; Williams GJ; Messerschmidt M; Boutet S; Blank VD; Shvyd'ko YV; Robert A Rev Sci Instrum; 2014 Jun; 85(6):063106. PubMed ID: 24985798 [TBL] [Abstract][Full Text] [Related]
15. Multiple-wave diffraction in high energy resolution back-reflecting x-ray optics. Stetsko YP; Keister JW; Coburn DS; Kodituwakku CN; Cunsolo A; Cai YQ Phys Rev Lett; 2011 Oct; 107(15):155503. PubMed ID: 22107300 [TBL] [Abstract][Full Text] [Related]
16. Collimating Montel mirror as part of a multi-crystal analyzer system for resonant inelastic X-ray scattering. Kim J; Shi X; Casa D; Qian J; Huang X; Gog T J Synchrotron Radiat; 2016 Jul; 23(Pt 4):880-6. PubMed ID: 27359136 [TBL] [Abstract][Full Text] [Related]
17. Ultra-stable sub-meV monochromator for hard X-rays. Toellner TS; Collins J; Goetze K; Hu MY; Preissner C; Trakhtenberg E; Yan L J Synchrotron Radiat; 2015 Sep; 22(5):1155-62. PubMed ID: 26289266 [TBL] [Abstract][Full Text] [Related]