These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 24514731)

  • 1. Calibrating optical tweezers with Bayesian inference.
    Richly MU; Türkcan S; Le Gall A; Fiszman N; Masson JB; Westbrook N; Perronet K; Alexandrou A
    Opt Express; 2013 Dec; 21(25):31578-90. PubMed ID: 24514731
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Auto- and cross-power spectral analysis of dual trap optical tweezer experiments using Bayesian inference.
    von Hansen Y; Mehlich A; Pelz B; Rief M; Netz RR
    Rev Sci Instrum; 2012 Sep; 83(9):095116. PubMed ID: 23020428
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Calibration of optical traps by dual trapping of one bead.
    Dutov P; Schieber J
    Opt Lett; 2013 Nov; 38(22):4923-6. PubMed ID: 24322167
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A strategy for Bayesian inference for computationally expensive models with application to the estimation of stem cell properties.
    Overstall AM; Woods DC
    Biometrics; 2013 Jun; 69(2):458-68. PubMed ID: 23421643
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pulsed laser manipulation of an optically trapped bead: averaging thermal noise and measuring the pulsed force amplitude.
    Lindballe TB; Kristensen MV; Berg-Sørensen K; Keiding SR; Stapelfeldt H
    Opt Express; 2013 Jan; 21(2):1986-96. PubMed ID: 23389179
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Counter-propagating dual-trap optical tweezers based on linear momentum conservation.
    Ribezzi-Crivellari M; Huguet JM; Ritort F
    Rev Sci Instrum; 2013 Apr; 84(4):043104. PubMed ID: 23635178
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High-resolution dual-trap optical tweezers with differential detection: minimizing the influence of measurement noise.
    Bustamante C; Chemla YR; Moffitt JR
    Cold Spring Harb Protoc; 2009 Oct; 2009(10):pdb.ip75. PubMed ID: 20147040
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simultaneous calibration of optical tweezers spring constant and position detector response.
    Le Gall A; Perronet K; Dulin D; Villing A; Bouyer P; Visscher K; Westbrook N
    Opt Express; 2010 Dec; 18(25):26469-74. PubMed ID: 21164997
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Power spectrum analysis with least-squares fitting: amplitude bias and its elimination, with application to optical tweezers and atomic force microscope cantilevers.
    Nørrelykke SF; Flyvbjerg H
    Rev Sci Instrum; 2010 Jul; 81(7):075103. PubMed ID: 20687755
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Bayesian adjustment for multiplicative measurement errors for a calibration problem with application to a stem cell study.
    Zhang P; Liu J; Dong J; Holovati JL; Letcher B; McGann LE
    Biometrics; 2012 Mar; 68(1):268-74. PubMed ID: 21689082
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Improvement of measurement uncertainties in laser power detector calibration by convolving with the detector's impulse response function.
    Xu T; Yu J; Zang E; Gan H
    Opt Express; 2012 Nov; 20(24):27018-23. PubMed ID: 23187557
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Supercontinuum trap stiffness measurement using a confocal approach.
    Zhang Z; Li H; Li P; Shi K; Edwards P; Omenetto F; Cronin-Golomb M; Zhang G; Liu Z
    Opt Express; 2010 Dec; 18(25):26499-504. PubMed ID: 21165001
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Calibration of optical tweezers based on an autoregressive model.
    Wang ZQ; Zhou JH; Zhong MC; Li D; Li YM
    Opt Express; 2014 Jul; 22(14):16956-64. PubMed ID: 25090511
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optical force sensor array in a microfluidic device based on holographic optical tweezers.
    Uhrig K; Kurre R; Schmitz C; Curtis JE; Haraszti T; Clemen AE; Spatz JP
    Lab Chip; 2009 Mar; 9(5):661-8. PubMed ID: 19224015
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Towards absolute calibration of optical tweezers.
    Viana NB; Rocha MS; Mesquita ON; Mazolli A; Maia Neto PA; Nussenzveig HM
    Phys Rev E Stat Nonlin Soft Matter Phys; 2007 Feb; 75(2 Pt 1):021914. PubMed ID: 17358374
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Bayesian model comparison approach to inferring positive selection.
    Scheffler K; Seoighe C
    Mol Biol Evol; 2005 Dec; 22(12):2531-40. PubMed ID: 16120799
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Estimation of cell Young's modulus of adherent cells probed by optical and magnetic tweezers: influence of cell thickness and bead immersion.
    Kamgoué A; Ohayon J; Tracqui P
    J Biomech Eng; 2007 Aug; 129(4):523-30. PubMed ID: 17655473
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Bayesian method for construction of Markov models to describe dynamics on various time-scales.
    Rains EK; Andersen HC
    J Chem Phys; 2010 Oct; 133(14):144113. PubMed ID: 20949993
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Guided tree topology proposals for Bayesian phylogenetic inference.
    Höhna S; Drummond AJ
    Syst Biol; 2012 Jan; 61(1):1-11. PubMed ID: 21828081
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bayesian interim analysis in clinical trials.
    Zhang X; Cutter G
    Contemp Clin Trials; 2008 Sep; 29(5):751-5. PubMed ID: 18589003
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.