These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 24517034)

  • 1. An investigation on the effect of groove geometry on cementless femoral stem component in hip arthroplasty.
    Rawal BR; Bhatnagar N
    Pak J Biol Sci; 2013 Dec; 16(24):2073-5. PubMed ID: 24517034
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
    Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Finite element analysis of cementless femoral stems based on mid- and long-term radiological evaluation.
    Matsuyama K; Ishidou Y; Guo YM; Kakoi H; Setoguchi T; Nagano S; Kawamura I; Maeda S; Komiya S
    BMC Musculoskelet Disord; 2016 Sep; 17(1):397. PubMed ID: 27642748
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Finite element analysis of optimal design of distal geometry of cementless femoral prosthesis.
    Zhao Y; Wang L; Bao Y; Xu R; He S
    Niger J Clin Pract; 2022 Sep; 25(9):1476-1483. PubMed ID: 36149207
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Influence of proximal stem geometry and stem-cement interface characteristics on bone and cement stresses in femoral hip arthroplasty: finite element analysis].
    Massin P; Astoin E; Lavaste F
    Rev Chir Orthop Reparatrice Appar Mot; 2003 Apr; 89(2):134-43. PubMed ID: 12844057
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Design process of cementless femoral stem using a nonlinear three dimensional finite element analysis.
    Baharuddin MY; Salleh ShH; Zulkifly AH; Lee MH; Noor AM; A Harris AR; Majid NA; Abd Kader AS
    BMC Musculoskelet Disord; 2014 Feb; 15():30. PubMed ID: 24484753
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Stem geometry changes initial femoral fixation stability of a revised press-fit hip prosthesis: A finite element study.
    Russell RD; Huo MH; Rodrigues DC; Kosmopoulos V
    Technol Health Care; 2016 Nov; 24(6):865-872. PubMed ID: 27434281
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modified metaphyseal-loading anterolaterally flared anatomic femoral stem: five- to nine-year prospective follow-up evaluation and results of three-dimensional finite element analysis.
    Kokubo Y; Uchida K; Oki H; Negoro K; Nagamune K; Kawaguchi S; Takeno K; Yayama T; Nakajima H; Sugita D; Yoshida A; Baba H
    Artif Organs; 2013 Feb; 37(2):175-82. PubMed ID: 23009086
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effects of necrotic lesion size and orientation of the femoral component on stress alterations in the proximal femur in hip resurfacing - a finite element simulation.
    Tai CL; Chen YC; Hsieh PH
    BMC Musculoskelet Disord; 2014 Aug; 15():262. PubMed ID: 25095740
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Finite element analysis on the hollow porous design at the proximal end of cementless femoral prosthesis stem.
    He S; Zhu J; Zhao J
    Niger J Clin Pract; 2019 Sep; 22(9):1276-1280. PubMed ID: 31489866
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Numerical evaluation of bone remodelling and adaptation considering different hip prosthesis designs.
    Levadnyi I; Awrejcewicz J; Gubaua JE; Pereira JT
    Clin Biomech (Bristol, Avon); 2017 Dec; 50():122-129. PubMed ID: 29100185
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The tridimensional geometry of the proximal femur should determine the design of cementless femoral stem in total hip arthroplasty.
    Wegrzyn J; Roux JP; Loriau C; Bonin N; Pibarot V
    Int Orthop; 2018 Oct; 42(10):2329-2334. PubMed ID: 29468265
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Nonlinear three-dimensional finite element analysis of newly designed cementless total hip stems.
    Ando M; Imura S; Omori H; Okumura Y; Bo A; Baba H
    Artif Organs; 1999 Apr; 23(4):339-46. PubMed ID: 10226698
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Increased risk of periprosthetic femur fractures associated with a unique cementless stem design.
    Watts CD; Abdel MP; Lewallen DG; Berry DJ; Hanssen AD
    Clin Orthop Relat Res; 2015 Jun; 473(6):2045-53. PubMed ID: 25502478
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Design and optimization of the oriented groove on the hip implant surface to promote bone microstructure integrity.
    Noyama Y; Nakano T; Ishimoto T; Sakai T; Yoshikawa H
    Bone; 2013 Feb; 52(2):659-67. PubMed ID: 23147000
    [TBL] [Abstract][Full Text] [Related]  

  • 16. On the secondary stability of coated cementless hip replacement: parameters that affected interface strength.
    Orlik J; Zhurov A; Middleton J
    Med Eng Phys; 2003 Dec; 25(10):825-31. PubMed ID: 14630470
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mid-Term Results of the SL-PLUS Femoral Prosthesis The Influence of Femoral Bone Type.
    Takigami I; Ito Y; Matsumoto K; Terabayashi N; Miyagawa T; Akiyama H
    Bull Hosp Jt Dis (2013); 2017 Apr; 75(2):128-133. PubMed ID: 28583059
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical and finite element analysis of a modular femoral prosthesis consisting of a head and stem component in the treatment of pertrochanteric fractures.
    Andress HJ; Kahl S; Kranz C; Gierer P; Schürmann M; Lob G
    J Orthop Trauma; 2000 Nov; 14(8):546-53. PubMed ID: 11149500
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Proximal and Distal Femoral Canal Geometry Influences Cementless Stem Anchorage and Revision Hip and Knee Implant Stability.
    Heinecke M; Rathje F; Layher F; Matziolis G
    Orthopedics; 2018 May; 41(3):e369-e375. PubMed ID: 29570762
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of the fixation region of a press-fit hip endoprosthesis on the stress-strain state of the "bone-implant" system.
    Levadnyi I; Awrejcewicz J; Goethel MF; Loskutov A
    Comput Biol Med; 2017 May; 84():195-204. PubMed ID: 28390287
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.