These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

253 related articles for article (PubMed ID: 24519619)

  • 1. Similar stability and range of motion between cruciate-retaining and cruciate-substituting ultracongruent insert total knee arthroplasty.
    Lützner J; Firmbach FP; Lützner C; Dexel J; Kirschner S
    Knee Surg Sports Traumatol Arthrosc; 2015 Jun; 23(6):1638-43. PubMed ID: 24519619
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Different intraoperative kinematics, stability, and range of motion between cruciate-substituting ultracongruent and posterior-stabilized total knee arthroplasty.
    Fritzsche H; Beyer F; Postler A; Lützner J
    Knee Surg Sports Traumatol Arthrosc; 2018 May; 26(5):1465-1470. PubMed ID: 28093635
    [TBL] [Abstract][Full Text] [Related]  

  • 3. No difference in range of motion between ultracongruent and posterior stabilized design in total knee arthroplasty: a randomized controlled trial.
    Lützner J; Beyer F; Dexel J; Fritzsche H; Lützner C; Kirschner S
    Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3515-3521. PubMed ID: 27659044
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Total knee arthroplasty using ultra-congruent inserts can provide similar stability and function compared with cruciate-retaining total knee arthroplasty.
    Song EK; Lim HA; Joo SD; Kim SK; Lee KB; Seon JK
    Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3530-3535. PubMed ID: 28439638
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Posterior-stabilized inserts are preferable to cruciate-substituting ultracongruent inserts due to more favourable kinematics and stability.
    Bae JH; Yoon JR; Sung JH; Shin YS
    Knee Surg Sports Traumatol Arthrosc; 2018 Nov; 26(11):3300-3310. PubMed ID: 29459998
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Different intraoperative kinematics with comparable clinical outcomes of ultracongruent and posterior stabilized mobile-bearing total knee arthroplasty.
    Kim TW; Lee SM; Seong SC; Lee S; Jang J; Lee MC
    Knee Surg Sports Traumatol Arthrosc; 2016 Sep; 24(9):3036-3043. PubMed ID: 25567541
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Limited effect of anatomical insert geometry on in vitro laxity in balanced anatomic posterior cruciate ligament retaining total knee arthroplasty.
    van Houten AH; Heesterbeek PJC; Hannink G; Labey L; Wymenga AB
    Knee Surg Sports Traumatol Arthrosc; 2022 Apr; 30(4):1273-1281. PubMed ID: 33860338
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mid-flexion stability in the anteroposterior plane is achieved with a medial congruent insert in cruciate-retaining total knee arthroplasty for varus osteoarthritis.
    Tsubosaka M; Ishida K; Kodato K; Shibanuma N; Hayashi S; Kurosaka M; Kuroda R; Matsumoto T
    Knee Surg Sports Traumatol Arthrosc; 2021 Feb; 29(2):467-473. PubMed ID: 32157363
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultracongruent insert design is a safe alternative to posterior cruciate-substituting total knee arthroplasty: 5-year results of a randomized controlled trial.
    Lützner J; Beyer F; Lützner C; Riedel R; Tille E
    Knee Surg Sports Traumatol Arthrosc; 2022 Sep; 30(9):3000-3006. PubMed ID: 33842984
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Increased posterior translation but similar clinical outcomes using ultracongruent instead of posterior stabilized total knee arthroplasties in a prospective randomized trial.
    Hinarejos P; Leal-Blanquet J; Fraile-Suari A; Sánchez-Soler J; Torres-Claramunt R; Monllau JC
    Knee Surg Sports Traumatol Arthrosc; 2022 Sep; 30(9):3041-3048. PubMed ID: 34436635
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Posterior cruciate ligament resection in total knee arthroplasty: the effect on flexion-extension gaps, mediolateral laxity, and fixed flexion deformity.
    Kayani B; Konan S; Horriat S; Ibrahim MS; Haddad FS
    Bone Joint J; 2019 Oct; 101-B(10):1230-1237. PubMed ID: 31564152
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Anteroposterior translation and range of motion after total knee arthroplasty using posterior cruciate ligament-retaining versus posterior cruciate ligament-substituting prostheses.
    Ishii Y; Noguchi H; Sato J; Sakurai T; Toyabe SI
    Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3536-3542. PubMed ID: 27485124
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mobile-bearing insert translational and rotational kinematics in a PCL-retaining total knee arthroplasty.
    Chouteau J; Lerat JL; Testa R; Moyen B; Fessy MH; Banks SA
    Orthop Traumatol Surg Res; 2009 Jun; 95(4):254-9. PubMed ID: 19442597
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Similar outcomes between ultracongruent and posterior-stabilized insert in total knee arthroplasty: A propensity score-matched analysis.
    Lee SS; Yeom J; Lee DH; Moon YW
    J Orthop Surg (Hong Kong); 2020; 28(1):2309499019893515. PubMed ID: 31876242
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Can high-flexion tibial inserts improve range of motion after posterior cruciate-retaining total knee arthroplasty?
    Crow BD; McCauley JC; Ezzet KA
    Orthopedics; 2010 Sep; 33(9):667. PubMed ID: 20839712
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The relationship between anteroposterior stability and medial-lateral stability of the bi-cruciate stabilized total knee arthroplasty.
    Inui H; Taketomi S; Yamagami R; Kawaguchi K; Nakazato K; Tanaka S
    Knee; 2018 Dec; 25(6):1247-1253. PubMed ID: 30414789
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Comparison of 2 Tibial Inserts of Different Constraint for Cruciate-Retaining Primary Total Knee Arthroplasty: An Additional Tool for Balancing the Posterior Cruciate Ligament.
    Emerson RH; Barrington JW; Olugbode SA; Alnachoukati OK
    J Arthroplasty; 2016 Feb; 31(2):425-8. PubMed ID: 26481407
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Total knee arthroplasty in-vivo kinematics changes after insert replacement for posterior cruciate ligament deficiency: a case report.
    Daffara V; Zambianchi F; Gualandris T; Seracchioli S; Marcovigi A; Catani F
    Acta Biomed; 2023 Jun; 94(S1):e2023134. PubMed ID: 37272625
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intraoperative posterior movement of the tibia at 90° of flexion predicts worse postoperative flexion angles in cruciate-substituting total knee arthroplasty.
    Inokuchi T; Ishida K; Takayama K; Shibanuma N; Hayashi S; Kurosaka M; Kuroda R; Matsumoto T
    Knee Surg Sports Traumatol Arthrosc; 2020 Sep; 28(9):2816-2822. PubMed ID: 31324963
    [TBL] [Abstract][Full Text] [Related]  

  • 20. CR-lipped bearing is an adequate functional solution to patients with perioperative excessive laxity in cruciate retaining total knee arthroplasty.
    Kalaai S; van Dun B; Boonen B; van Haaren EH; Schotanus MGM
    Knee; 2021 Jan; 28():51-56. PubMed ID: 33307319
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.