BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

332 related articles for article (PubMed ID: 24522674)

  • 1. Automated office blood pressure measurement in primary care.
    Myers MG; Kaczorowski J; Dawes M; Godwin M
    Can Fam Physician; 2014 Feb; 60(2):127-32. PubMed ID: 24522674
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Replacing manual sphygmomanometers with automated blood pressure measurement in routine clinical practice.
    Myers MG
    Clin Exp Pharmacol Physiol; 2014 Jan; 41(1):46-53. PubMed ID: 23819734
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparing Automated Office Blood Pressure Readings With Other Methods of Blood Pressure Measurement for Identifying Patients With Possible Hypertension: A Systematic Review and Meta-analysis.
    Roerecke M; Kaczorowski J; Myers MG
    JAMA Intern Med; 2019 Mar; 179(3):351-362. PubMed ID: 30715088
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automated office blood pressure.
    Myers MG; Godwin M
    Can J Cardiol; 2012 May; 28(3):341-6. PubMed ID: 22265230
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of awake ambulatory blood pressure and automated office blood pressure using linear regression analysis in untreated patients in routine clinical practice.
    Myers MG; Matangi M; Kaczorowski J
    J Clin Hypertens (Greenwich); 2018 Dec; 20(12):1696-1702. PubMed ID: 30328275
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Office blood pressure measurement in the 21st century.
    Myers MG; Asmar R; Staessen JA
    J Clin Hypertens (Greenwich); 2018 Jul; 20(7):1104-1107. PubMed ID: 30003698
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of Automated Office Blood Pressure With Office and Out-Off-Office Measurement Techniques.
    Pappaccogli M; Di Monaco S; Perlo E; Burrello J; D'Ascenzo F; Veglio F; Monticone S; Rabbia F
    Hypertension; 2019 Feb; 73(2):481-490. PubMed ID: 30624994
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Why use automated office blood pressure measurements in clinical practice?
    Andreadis EA; Angelopoulos ET; Agaliotis GD; Tsakanikas AP; Mousoulis GP
    High Blood Press Cardiovasc Prev; 2011 Sep; 18(3):89-91. PubMed ID: 21950780
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Conventional versus automated measurement of blood pressure in the office (CAMBO) trial.
    Myers MG; Godwin M; Dawes M; Kiss A; Tobe SW; Kaczorowski J
    Fam Pract; 2012 Aug; 29(4):376-82. PubMed ID: 22117083
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Are Automated Office Blood Pressure Readings More Variable Than Home Readings?
    Myers MG; Kaczorowski J
    Hypertension; 2020 May; 75(5):1179-1183. PubMed ID: 32200678
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The great myth of office blood pressure measurement.
    Myers MG
    J Hypertens; 2012 Oct; 30(10):1894-8. PubMed ID: 22871894
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Attended and Unattended Automated Office Blood Pressure Measurements Have Better Agreement With Ambulatory Monitoring Than Conventional Office Readings.
    Andreadis EA; Geladari CV; Angelopoulos ET; Savva FS; Georgantoni AI; Papademetriou V
    J Am Heart Assoc; 2018 Apr; 7(8):. PubMed ID: 29627767
    [TBL] [Abstract][Full Text] [Related]  

  • 13. How do family physicians measure blood pressure in routine clinical practice? National survey of Canadian family physicians.
    Kaczorowski J; Myers MG; Gelfer M; Dawes M; Mang EJ; Berg A; Grande CD; Kljujic D
    Can Fam Physician; 2017 Mar; 63(3):e193-e199. PubMed ID: 28292817
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Preference of blood pressure measurement methods by primary care doctors in Hong Kong: a cross-sectional survey.
    Lee EKP; Choi RCM; Liu L; Gao T; Yip BHK; Wong SYS
    BMC Fam Pract; 2020 May; 21(1):95. PubMed ID: 32456619
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Automated office versus home measurement of blood pressure in the assessment of morning hypertension.
    Andreadis EA; Angelopoulos ET; Tsakanikas AP; Agaliotis GD; Kravvariti SD; Mousoulis GP
    Blood Press Monit; 2012 Feb; 17(1):24-34. PubMed ID: 22218221
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Conventional versus automated measurement of blood pressure in primary care patients with systolic hypertension: randomised parallel design controlled trial.
    Myers MG; Godwin M; Dawes M; Kiss A; Tobe SW; Grant FC; Kaczorowski J
    BMJ; 2011 Feb; 342():d286. PubMed ID: 21300709
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison Between Automated Office Blood Pressure Measurements and Manual Office Blood Pressure Measurements-Implications in Individual Patients: a Systematic Review and Meta-analysis.
    Bo Y; Kwok KO; Chu KK; Leung EY; Yu CP; Wong SY; Lee EK
    Curr Hypertens Rep; 2021 Jan; 23(1):4. PubMed ID: 33452580
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Automated Office-Based Blood Pressure Measurement: an Overview and Guidance for Implementation in Primary Care.
    Boonyasai RT; McCannon EL; Landavaso JE
    Curr Hypertens Rep; 2019 Apr; 21(4):29. PubMed ID: 30949872
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Identification of the Optimal Protocol for Automated Office Blood Pressure Measurement Among Patients With Treated Hypertension.
    Moore MN; Schultz MG; Nelson MR; Black JA; Dwyer NB; Hoban E; Jose MD; Kosmala W; Przewlocka-Kosmala M; Zachwyc J; Otahal P; Picone DS; Roberts-Thomson P; Veloudi P; Sharman JE
    Am J Hypertens; 2018 Feb; 31(3):299-304. PubMed ID: 29126128
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Threshold for diagnosing hypertension by automated office blood pressure using random sample population data.
    Wohlfahrt P; Cífková R; Movsisyan N; Kunzová Š; Lešovský J; Homolka M; Soška V; Bauerová H; Lopez-Jimenez F; Sochor O
    J Hypertens; 2016 Nov; 34(11):2180-6. PubMed ID: 27512968
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.