BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

766 related articles for article (PubMed ID: 24530834)

  • 21. Immobilization of specific monoclonal antibody on Au nanoparticles for hGH detection by electrochemical impedance spectroscopy.
    Rezaei B; Khayamian T; Majidi N; Rahmani H
    Biosens Bioelectron; 2009 Oct; 25(2):395-9. PubMed ID: 19692224
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A CdTe nanoparticle-modified hairpin probe for direct and sensitive electrochemical detection of DNA.
    Kjällman TH; Peng H; Soeller C; Travas-Sejdic J
    Analyst; 2010 Mar; 135(3):488-94. PubMed ID: 20174700
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Electrochemical sensor based on gold nanoparticles fabricated molecularly imprinted polymer film at chitosan-platinum nanoparticles/graphene-gold nanoparticles double nanocomposites modified electrode for detection of erythromycin.
    Lian W; Liu S; Yu J; Xing X; Li J; Cui M; Huang J
    Biosens Bioelectron; 2012; 38(1):163-9. PubMed ID: 22683249
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Gold nanoparticles modified electrode via a mercapto-diazoaminobenzene monolayer and its development in DNA electrochemical biosensor.
    Li F; Feng Y; Dong P; Tang B
    Biosens Bioelectron; 2010 May; 25(9):2084-8. PubMed ID: 20207131
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparative electrochemical study of new self-assembled monolayers of 2-{[(Z)-1-(3-furyl)methylidene]amino}-1-benzenethiol and 2-{[(2-sulfanylphenyl)imino]methyl}phenol for determination of dopamine in the presence of high concentration of ascorbic acid and uric acid.
    Behpour M; Ghoreishi SM; Honarmand E; Salavati-Niasari M
    Analyst; 2011 May; 136(9):1979-86. PubMed ID: 21409249
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Fabrication of chronocoulometric DNA sensor based on gold nanoparticles/poly(l-lysine) modified glassy carbon electrode.
    Wang J; Zhang S; Zhang Y
    Anal Biochem; 2010 Jan; 396(2):304-9. PubMed ID: 19818728
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Label free detection of lead using impedimetric sensor based on ordered mesoporous carbon-gold nanoparticles and DNAzyme catalytic beacons.
    Zhou Y; Tang L; Zeng G; Zhang C; Xie X; Liu Y; Wang J; Tang J; Zhang Y; Deng Y
    Talanta; 2016 Jan; 146():641-7. PubMed ID: 26695312
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect of probe density and hybridization temperature on the response of an electrochemical hairpin-DNA sensor.
    Kjällman TH; Peng H; Soeller C; Travas-Sejdic J
    Anal Chem; 2008 Dec; 80(24):9460-6. PubMed ID: 19006336
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Voltammetric and impedimetric DNA detection at single-use graphite electrodes modified with gold nanorods.
    Congur G; Sayar F; Erdem A; Piskin E
    Colloids Surf B Biointerfaces; 2013 Dec; 112():61-6. PubMed ID: 23958523
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Amperometric detection of catechol using tyrosinase modified electrodes enhanced by the layer-by-layer assembly of gold nanocubes and polyelectrolytes.
    Karim MN; Lee JE; Lee HJ
    Biosens Bioelectron; 2014 Nov; 61():147-51. PubMed ID: 24874658
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Hairpin DNA as a biobarcode modified on gold nanoparticles for electrochemical DNA detection.
    Cui HF; Xu TB; Sun YL; Zhou AW; Cui YH; Liu W; Luong JH
    Anal Chem; 2015 Jan; 87(2):1358-65. PubMed ID: 25530496
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Electrochemical behavior of gold colloidal alkyl modified silicon surfaces.
    Le Saux G; Ciampi S; Gaus K; Gooding JJ
    ACS Appl Mater Interfaces; 2009 Nov; 1(11):2477-83. PubMed ID: 20356117
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Development of electrochemical DNA biosensor based on gold nanoparticle modified electrode by electroless deposition.
    Liu S; Liu J; Wang L; Zhao F
    Bioelectrochemistry; 2010 Aug; 79(1):37-42. PubMed ID: 19914151
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Electrochemical synthesis of gold nanostructure modified electrode and its development in electrochemical DNA biosensor.
    Wang L; Chen X; Wang X; Han X; Liu S; Zhao C
    Biosens Bioelectron; 2011 Dec; 30(1):151-7. PubMed ID: 21963391
    [TBL] [Abstract][Full Text] [Related]  

  • 35. An impedimetric biosensor for E. coli O157:H7 based on the use of self-assembled gold nanoparticles and protein G.
    Lin D; Pillai RG; Lee WE; Jemere AB
    Mikrochim Acta; 2019 Feb; 186(3):169. PubMed ID: 30741345
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Electrochemical impedance immunosensor based on gold nanoparticles and aryl diazonium salt functionalized gold electrodes for the detection of antibody.
    Liu G; Liu J; Davis TP; Gooding JJ
    Biosens Bioelectron; 2011 Apr; 26(8):3660-5. PubMed ID: 21398105
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Electrochemical biosensor based on self-assembled monolayers modified with gold nanoparticles for detection of HER-3.
    Canbaz MÇ; Simşek CS; Sezgintürk MK
    Anal Chim Acta; 2014 Mar; 814():31-8. PubMed ID: 24528841
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Aptamer-based electrochemical approach to the detection of thrombin by modification of gold nanoparticles.
    Li L; Zhao H; Chen Z; Mu X; Guo L
    Anal Bioanal Chem; 2010 Sep; 398(1):563-70. PubMed ID: 20607523
    [TBL] [Abstract][Full Text] [Related]  

  • 39. An electrochemical DNA biosensor based on gold nanorods decorated graphene oxide sheets for sensing platform.
    Han X; Fang X; Shi A; Wang J; Zhang Y
    Anal Biochem; 2013 Dec; 443(2):117-23. PubMed ID: 24012578
    [TBL] [Abstract][Full Text] [Related]  

  • 40. An impedimetric aptasensor for Shigella dysenteriae using a gold nanoparticle-modified glassy carbon electrode.
    Zarei SS; Soleimanian-Zad S; Ensafi AA
    Mikrochim Acta; 2018 Nov; 185(12):538. PubMed ID: 30413894
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 39.